Pressure Detection Instruments
Filter
Showing 1–30 of 39 results
| Brand | ADCON |
|---|---|
| Origin | Switzerland |
| Model | PA-1 |
| Pressure Range | 0–10 bar (absolute) |
| Overpressure Limit | 20 bar |
| Operating Temperature | −40 °C to +80 °C |
| Compensated Temperature Range | 0 °C to +50 °C |
| Accuracy (0–50 °C) | ±0.1% FS typical, ±1.5% FS max |
| Linearity | ±0.25% FS typical, ±0.5% FS max |
| Sensing Principle | Piezoresistive |
| Output Signal | 0.1–2.5 V ratiometric |
| Supply Voltage | 3.5–12 V DC |
| Thread Connection | G 1/4" (NPT & G 1/2" adapters available) |
| Housing Diameter | 22 mm |
| Length | 49 mm |
| Weight | 30 g |
| Cable | Shielded PVC2 |
| Cable Length Options | 5 m or 10 m |
| Connector | 4-pin M12 male on sensor, 4-pin M12 female + 7-pin Binder M9 male on cable |
| IP Rating | IP67 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AKS-P8002 |
| Pressure Range | Up to 250 MPa |
| Accuracy Class | 0.02% / 0.05% (depending on range) |
| Pressure Port | M20×1.5 male thread & Φ6 mm quick-connect (differential type) |
| Electrical Test | Voltage (-30–30 V), Current (-30–30 mA), Switch Test, 24 V Loop Power |
| Dimensions | Ø120 mm × 46 mm (head), Total Length 184 mm |
| Weight | 0.7 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SC4-18, SC4-31, SC4-34, SC4-16, SC4-25Z, KU-1030, KU-1031, T-A–T-F, SA-70, SSA, BTU-18Y, SC4-DSY, SC4-13RPY, SC4-13RD, SC4-27SD, SC4-27 Link Hanging Assembly |
| Shear Rate Range | Instrument-dependent (DVNext/RV series) |
| Torque Range | 0.28–1.32 N·cm |
| Sample Volume | 4.2–9.4 mL |
| Material | 316 Stainless Steel (standard), Anodized Aluminum (select spindles) |
| Compliance | ASTM D1200, ISO 2555, ISO 3219, USP <911>, GLP-ready with audit-trail-capable software |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | HPC40 Series |
| Pressure Range | Up to 15,000 psi (1000 bar / 100 MPa) |
| Accuracy | ±0.035% of reading |
| Operating Temperature Compensation | Full-range compensation from −20 °C to +50 °C |
| Functionality | Simultaneous pressure measurement & mA loop sourcing/sinking (0–24 mA), voltage measurement (0–30 VDC), temperature measurement via Pt100/Pt1000 (True Ohms mode) |
| Interface | Menu-free, direct-access button layout |
| Power Options | Rechargeable Li-ion battery with AC adapter |
| Design | Modular, field-serviceable architecture |
| Calibration Targets | Analog and digital pressure gauges, transmitters, switches, and I/P converters |
| Compliance | Designed for traceable calibration in accordance with ISO/IEC 17025, ASTM E74, and EN 837-1 |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | nVision Reference Recorder |
| Type | Pressure Calibrator |
| Calibration Target | Pressure Controllers |
| Design | Modular Architecture |
| Pressure Range | Up to 15000 psi (1000 bar, 100 MPa) |
| Accuracy (Differential Pressure) | ±0.025% of reading |
| Data Storage | 500,000 points |
| Sampling Rate | 10 readings per second per 2 modules |
| Environmental Rating | Submersible to 3 ft (≈0.9 m) |
| Operating Temperature Range | −20 °C to +50 °C |
| Thermal Compensation | Full accuracy compensation across −20 °C to +50 °C |
| Certification | A2LA-accredited calibration certificate with test data at five temperature points |
| Input/Output Capabilities | Gauge & absolute pressure, switch status, voltage, current, and temperature |
| Brand | Crystal |
|---|---|
| Origin | Denmark |
| Model | XP2i-DP |
| Type | Intrinsically Safe Wet/Wet Differential Pressure Gauge |
| Accuracy | ±0.1% of full scale |
| Measurement Range | Vacuum to Positive Differential Pressure |
| Housing | Marine-grade corrosion-resistant stainless steel (316 SS) |
| Configuration | Panel-mount or portable |
| Pressure Units | User-selectable (kPa, bar, psi, inH₂O, mmH₂O, mbar, etc.) |
| Data Logging | Optional DataLoggerXP module (32,000-point capacity, 1-year continuous logging in ULP mode) |
| Power | Optimized long-life battery with Ultra-Low-Power (ULP) operation |
| Compliance | ATEX/IECEx certified for hazardous areas (Zone 0/1, Class I Div 1), IP67 ingress protection |
| Brand | Elveflow |
|---|---|
| Origin | France |
| Model | MPS |
| Accuracy | ±0.2 % FS |
| Pressure Ranges | 70–7,000 mbar (5 selectable full-scale options) |
| Internal Volume | 7 µL |
| Response Time (Stabilization) | 20 ms |
| Media Compatibility | Liquids and Gases |
| Connection | Compatible with 3/32" ID tubing or 10-32 threaded fitting for 1/16" OD tubing |
| Type | Gauge Pressure Sensor (relative to ambient atmospheric pressure) |
| Brand | Biaozhuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LKY-005 |
| Price | USD 2,380 (FOB Shanghai) |
| Measurement Range | 0–100 mm |
| Repeatability | ±0.05 mm |
| Resolution | 0.01 mm |
| Maximum Permissible Error | ±(0.03 + 0.003L) mm (calibrated against Grade 2 gauge blocks) |
| Compliance | JJG 146–2003 (Chinese National Verification Regulation for Gauge Blocks) |
| Brand | Fischer |
|---|---|
| Origin | Germany |
| Model | DE90 |
| Measurement Principle | Piezoresistive Ceramic Sensor Technology |
| Output Signal | 4–20 mA (2-wire), optional 0–10 V |
| Accuracy | ±0.1 % FS |
| Long-Term Stability | <0.1 % FS/year |
| Operating Temperature Range | –20 to +70 °C |
| Enclosure Rating | IP65 |
| Media Compatibility | Air and neutral gases |
| Max. Overpressure | 5× full scale |
| Supply Voltage | 12–36 V DC |
| Response Time | <100 ms |
| Certifications | CE, RoHS, optionally ATEX II 3G Ex nA IIC T4 Ga (for DE43 variant), compliant with DIN EN 61326-1 (EMC), DIN EN 61000-6-2/6-4 |
| Brand | KEYENCE |
|---|---|
| Origin | Japan |
| Manufacturer | KEYENCE Corporation |
| Product Type | Imported Industrial Pressure Sensor |
| Model | GP-M Series |
| Pricing | Available Upon Request |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPT Series |
| Output Options | RS232 / RS485 Digital or 0–5 VDC Analog |
| Accuracy | ±0.05% FSO over –40 to +85 °C |
| EMC Protection | Enhanced EMI Shielding per EN 61326-1 |
| Certifications | CE Marked (EMC & LVD Directives) |
| Dual Outputs | Independent Pressure and Sensor Temperature Signals |
| Compliance | Meets EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission) |
| Brand | Honeywell |
|---|---|
| Origin | USA |
| Model | PPT-R |
| Certification | FM, CSA, CE |
| Operating Temperature Range | –40 °C to +85 °C |
| Accuracy | ±0.05% FS (Full Scale Output) |
| Output Options | 0–5 VDC analog output |
| Digital Interface | RS232 / RS485 compatible |
| Enclosure | Hermetically Sealed, Ruggedized Housing with Integrated Cable |
| Compliance | ATEX Zone 1/21, IECEx, UL 913 Class I Div 1, EN 60079-0/-11 |
| Brand | INFICON |
|---|---|
| Origin | Germany |
| Model | IC6 Thin Film Deposition Controller |
| Measurement Principle | Quartz Crystal Microbalance (QCM) with ModeLock Frequency Detection |
| Resolution | 0.00433 Å/s @ 100 ms sampling |
| Frequency Stability | ±0.0035 Hz |
| Max Simultaneous Sources | 6 |
| Layer Capacity | 50 processes × 200 layers = 10,000 total layers |
| Sensor Inputs | Up to 8 QCM sensors (averaged or independent) |
| Display | Color TFT LCD |
| I/O | 28 digital inputs, 24 relay outputs, 14 TTL outputs, 6 standard DACs + 6 optional DACs |
| Logic Engine | 100 programmable logic statements |
| Data Storage | Internal logging, screenshot capture, recipe storage |
| Communication | RS-232/485, optional Ethernet |
| Compliance | RoHS-compliant |
| Software Support | IC6 Configuration Editor (LabVIEW®-based, Windows®) |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Model | 6850+ |
| Pressure Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Velocity Range | 0.20–60.0 m/s |
| Velocity Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Velocity Resolution | 0.01 m/s |
| Flow Rate Range | 0–999999 m³/h |
| Flow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage | 10,000 records with USB export capability |
| Measurement Media | Air and non-corrosive gases |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6850 |
| Measurement Range | −2500 to +2500 Pa |
| Accuracy | ±0.5% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Wind Speed Range | 0.20–60.0 m/s |
| Wind Speed Accuracy | ±1.5% of reading (at 10.0 m/s) |
| Wind Speed Resolution | 0.01 m/s |
| Airflow Volume Range | 0–999,999 m³/h |
| Airflow Resolution | 1 m³/h |
| Operating Temperature | 0–60 °C (non-condensing) |
| Storage Temperature | −20–70 °C (non-condensing) |
| Power Supply | 4 × AA batteries or DC 5 V AC adapter |
| Battery Life | >15 hours |
| Weight (with batteries) | ~360 g |
| Display | Full-color LCD |
| Data Storage Capacity | 10,000 records |
| Data Export | USB flash drive (FAT32 formatted) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XTL Series |
| Price | Upon Request |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | RK-PM300 |
| Output Interface | RS-485 (Modbus RTU) |
| Enclosure Material | Stainless Steel (316L) |
| Protection Rating | IP54 |
| Supply Voltage | 10–30 VDC |
| Overvoltage Protection | Up to 2× Full Scale |
| Temperature Compensation | Built-in Automatic Compensation |
| Pressure Range Options | –0.1 to 60 MPa (gauge, vacuum, absolute) |
| Communication Distance | Up to 2000 m |
| Compliance | EMI Immunity per IEC 61000-6-2, RoHS Directive 2011/65/EU |
| Optional Dual Measurement | Simultaneous Pressure & Inlet Port Temperature |
| Brand | RenKe |
|---|---|
| Model | RS-QY-N01-2 |
| Measurement Principle | Piezoresistive Sensing with Integrated Temperature Compensation |
| Pressure Range | 0–120 kPa |
| Temperature Range | −40 to +80 °C (standard) |
| Pressure Accuracy | ±0.15 kPa @ 25 °C, 75 kPa |
| Temperature Accuracy | ±0.5 °C @ 25 °C |
| Long-Term Stability | ≤−0.1 kPa/year (pressure), ≤0.1 °C/year (temperature) |
| Output | RS-485 Modbus RTU (default baud rate: 4800, 8N1) |
| Power Supply | 10–30 V DC |
| Power Consumption | ≤0.5 W |
| Response Time | ≤1 s |
| Operating Environment | −20 to +60 °C, 0–80 %RH |
| Enclosure Type | Wall-Mounted IP65 Housing |
| Compliance | CE-marked design principles, RoHS-compliant materials, compatible with ISO/IEC 17025-aligned calibration workflows |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HART375 |
| Instrument Type | HART Protocol Field Communicator |
| Calibration Target | HART-enabled Pressure Transmitters, Temperature Transmitters, Flow Meters |
| Design | Integrated Handheld Unit |
| Application Environment | Industrial Plant Floors, Control Rooms, Field Maintenance Zones |
| Communication Modes | Point-to-Point, Multi-Drop (4–20 mA Loop), HART Primary Master Emulation |
| Supported Devices | All HART Revision 5–7 compliant field instruments |
| Power Source | Internal Rechargeable Li-ion Battery (Typical Runtime: >12 h continuous operation) |
| Loop Interface | Built-in 250 Ω precision resistor, loop-powered operation |
| Display | 3.5" TFT LCD (320 × 240 pixels), sunlight-readable with adjustable backlight |
| Environmental Rating | IP65 (Dust-tight, water-jet resistant) |
| Operating Temperature | –10 °C to +50 °C |
| Compliance | IEC 61000-4-2 (ESD), IEC 61000-4-3 (Radiated Immunity), ATEX/IECEx Zone 2 / Class I Div 2 (Optional Certified Variant Available) |
| Brand | Shanghai Xiande |
|---|---|
| Origin | Shanghai, China |
| Model | GMVC-3000pro |
| Control Range | 1–800 mmHg (Torr), 1–1066 hPa (mbar), 0–106.6 kPa, 0 to –0.01 MPa |
| Pressure Type | Negative (Vacuum) |
| Display | Digital Touchscreen (5.5″ Color LCD) |
| Ultimate Vacuum | 8 mbar |
| Max Pumping Speed | 20 or 30 L/min |
| Interface | Quick-Connect Ø10 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 130 W |
| Standby Power | 3 W |
| Noise Level | ≤55 dB(A) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP20 |
| Dimensions (L×W×H) | 185 × 310 × 310 mm |
| Weight | 13 kg |
| Optional Steam Temperature Monitoring | –20 to 200 °C |
| Brand | TAMASAKI (Kyoto) |
|---|---|
| Origin | Japan |
| Model | AMS-115 |
| Measurement Principle | Digital Current/Voltage/Time Synchronization |
| Measurement Range | 50 A – 999 kA (selectable) |
| Time Resolution | 1 ms |
| Max Monitoring Duration | 9,000 cycles (180 s for AMS-116) |
| Sampling Frequency | Up to 600 Hz |
| Input Channels | Primary current, secondary voltage, electrode displacement (optional), trigger signal |
| Output Interfaces | RS-232C (standard), digital I/O (optional) |
| Configuration Memory | 32 programmable welding condition sets |
| Compliance | Designed for ISO 14001 & JIS B 8711-compliant resistance welding process validation |
| Brand | TAMASAKI (Kyoto) |
|---|---|
| Origin | Japan |
| Model | SP-270-F200N |
| Measurement Principle | Strain-gauge-based force transduction |
| Measurement Range | 20–200 N (F200N variant) |
| Accuracy | ±1% F.S. |
| Overload Capacity | 120% of rated load |
| Output | DC ±2 V F.S. |
| Display | 4-inch TFT color LCD (Japanese/English selectable) |
| Data Sampling | Up to 1 kHz (1 ms interval) via USB |
| Power Supply | Rechargeable battery or USB bus power |
| Auto-power-off | Configurable timeout |
| Operating Temperature | 5–40 °C |
| Sensor Interchangeable | Yes (F200N, F1000N, F10kN, F30kN, F50kN variants) |
| Dimensions (H×W×D) | 140 × 85 × 35 mm |
| Weight (unit + sensor) | 600 g |
| Compliance | Designed for industrial welding process validation per JIS Z 3140 and ISO 14324 Annex B |
| Brand | SPOTRON (TAMASAKI) |
|---|---|
| Origin | Japan |
| Model | SP-3510 |
| Measurement Principle | Rogowski coil-based current sensing + precision shunt/voltage divider |
| Current Range | 1.0–500 kA (RMS or peak) |
| Voltage Range | 0–60.0 V (RMS or peak) |
| Time Measurement | 0.5–9999 cycles (50/60 Hz) or 0.1–9999 ms |
| Accuracy | ±2% FS (current), ±1% FS (voltage), ±0.5 cycle / ±0.1 ms (time) |
| Display | 3.5″ TFT LCD touchscreen (240×320 pixels) |
| Data Storage | SD card (included), USB 2.0 host/device interface |
| Power | Rechargeable lead-acid battery + universal AC adapter (100–240 V, 50/60 Hz) |
| Dimensions | 145 × 183 × 65 mm |
| Weight | ~1.9 kg |
| Compliance | Designed for industrial welding process validation per ISO 14324, AWS D8.8, and JIS Z 3136 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GXY-02 |
| Force Sensor Range | 200 N |
| Displacement Resolution | 0.001 mm |
| Deflection Measurement Range | 0–5 mm |
| Accuracy | ±0.01 mm (deflection), ±0.1 N (load), ±0.5 mm (span adjustment) |
| Specimen Span Adjustment | 0–55 mm |
| Needle Outer Diameter Compatibility | 0.3–3.4 mm (normal, thin, and ultra-thin wall) |
| Loading Speed | 1 mm/min ±0.1 mm/min |
| Dimensions | 460 × 340 × 400 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 45–80% RH (non-condensing) |
| Power Supply | 220 V ±22 V, 50 Hz ±11 Hz |
| Brand | SumSpring |
|---|---|
| Model | GXY-02 |
| Measurement Principle | Controlled bending force application with high-resolution deflection sensing |
| Deflection Range | 0–5 mm (±0.01 mm accuracy) |
| Load Range | 1–60 N (±0.1 N accuracy) |
| Needle Diameter Compatibility | 0.3–3.4 mm (standard, thin-wall, and ultra-thin-wall tubing) |
| Support Span Adjustment | 0–55 mm (±0.5 mm accuracy) |
| Loading Speed | 1 mm/min (±0.1 mm/min) |
| Dimensions | 460 × 340 × 400 mm |
| Weight | 25 kg |
| Power Supply | 220 V ± 10 %, 50 Hz ± 2 % |
| Operating Environment | 5–40 °C, RH 45–80 % (non-condensing) |
| Compliance Standards | GB 15811, GB 18457, YBB00092004–2015 |
| Brand | SumSpring |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GXY-02 |
| Force Sensor Range | 5.5–60 N (±0.1 N) |
| Deflection Measurement Range | 0–5 mm (±0.01 mm) |
| Support Span Adjustment | 0–55 mm (±0.5 mm) |
| Needle ID Compatibility | 0.3–3.4 mm (normal/thin/ultra-thin wall) |
| Loading Speed | 1 mm/min (±0.1 mm/min) |
| Displacement Resolution | 0.001 mm |
| Dimensions | 460 × 340 × 400 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 45–80% RH (non-condensing) |
| Power Supply | 220 V ± 10%, 50 Hz ± 2% |
| Brand | TAMASAKI |
|---|---|
| Origin | Japan |
| Model | SP-255-FU20kN |
| Measurement Principle | Hydraulic transduction with strain-gauge-based pressure sensing |
| Measurement Range | 2.0 kN to 20.0 kN |
| Resolution | 0.1 kN (10 kgf) |
| Accuracy | ±1% of full scale (FS) |
| Operating Temperature | 0 °C to 40 °C |
| Power Supply | 2 × AA alkaline batteries |
| Battery Life | ≥8 hours (continuous operation) |
| Auto-zero Function | Yes |
| Peak Hold & Data Hold | Yes |
| Auto-power-off | After 5 minutes of inactivity |
| Display Update Rate | 2 Hz (refresh every 0.5 s, with 64 samples/sec internal acquisition) |
| Sensor Housing | Integrated hydraulic insulation structure |
| Weight | 610 g (sensor head + 1.5 m cable), 430 g (main unit with batteries) |
| Brand | testo |
|---|---|
| Model | 0560 0511 |
| Measurement Range | 300–1200 hPa |
| Accuracy | ±3 hPa ± 1 digit |
| Resolution | 0.1 hPa |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Protection Class | IP40 |
| Weight | 90 g (incl. batteries and protective cap) |
| Dimensions | 119 × 46 × 25 mm (incl. cap) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 200 h (backlight off) |
| Measurable Units | hPa, mbar, Pa, mmH₂O, inH₂O, mmHg, inHg, psi, kPa |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 0550 |
| Pressure Range | −1 to +60 bar (rel.), −1 to 0 bar (vacuum) |
| Temperature Range | −50 to +150 °C |
| Pressure Accuracy | ±0.5 % FS |
| Temperature Accuracy | ±0.5 °C |
| Resolution | 0.01 bar / 0.1 °C |
| Weight | 1060 g |
| Dimensions | 200 × 109 × 63 mm |
| IP Rating | IP42 |
| Battery Life | 250 h (no backlight, no Bluetooth®) |
| Refrigerants | 60 preloaded (including R134a, R404A, R410A, R454B, R744, R290, R600a, etc.) |
| Probe Interfaces | 2 × NTC plug-in, 3 × 7/16"–UNF pressure ports |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1550 |
| Pressure Range | −1 to 60 bar (gauge), −1 to 0 bar (vacuum) |
| Temperature Range | −50 to +150 °C |
| Accuracy | ±0.5 % FS (pressure), ±0.5 °C (temperature) |
| Resolution | 0.01 bar / 0.1 °C |
| Sensors | Dual temperature-compensated pressure sensors + 2 × NTC plug-in temperature probe inputs |
| Refrigerants | 60+ preloaded, updated via app |
| Bluetooth | v4.0, up to 20 m range |
| Display | Backlit large LCD |
| IP Rating | IP42 |
| Battery Life | 250 h (no backlight, no Bluetooth) |
| Weight | 2424 g |
| Dimensions | 200 × 109 × 63 mm |
| Operating Temp. | −20 to +50 °C |
| Compliance | CE, RoHS, EN 61326-1 (EMC), EN 61010-1 (safety) |