Empowering Scientific Discovery

Advantec DRA430DC Precision Benchtop Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Advantec (Tamasaki)
Origin Japan
Model DRA430DC
Heating Method Natural Convection
Temperature Range 40–300 °C
Temperature Control Accuracy ±1 °C at 300 °C
Temperature Uniformity ±10 °C at 300 °C
Ramp Time (RT → 300 °C) ~60 min
Internal Dimensions (W×D×H) 460 × 475 × 450 mm (effective height: 418 mm)
External Dimensions (W×D×H) 590 × 635 × 810 mm
Chamber Volume ~98 L
Shelf Capacity 9 positions @ 45 mm spacing
Exhaust Ports 2 × φ28 mm
Power Supply AC 100 V, 50/60 Hz, 12 A
Net Weight ~50 kg
Safety Dual independent thermal protection (PID controller + mechanical overheat cutoff)

Overview

The Advantec DRA430DC is a precision-engineered benchtop oven designed for stable, repeatable thermal processing in laboratory and quality control environments. Utilizing natural convection heating—without forced air circulation—the DRA430DC delivers uniform temperature distribution across its 98-liter chamber while minimizing sample disturbance, making it especially suitable for drying heat-sensitive materials, pre-conditioning test specimens, residual solvent removal, and standardized curing protocols per ISO 293, ASTM D618, or JIS K 6251. Its PID-controlled heating system maintains setpoint accuracy within ±1 °C at 300 °C under defined ambient conditions (23 °C, closed exhaust, no load), and the dual-stage thermal safety architecture—comprising both electronic proportional-integral-derivative regulation and a mechanically actuated independent overheat limiter—ensures compliance with IEC 61010-1 safety requirements for laboratory equipment.

Key Features

  • Natural convection design eliminates airflow-induced sample displacement or oxidation, preserving structural integrity of powders, polymers, and coated substrates during extended dwell cycles.
  • High-stability temperature control system with digital PID algorithm and 0.1 °C resolution display, factory-calibrated to NIST-traceable standards.
  • Dual independent thermal protection: primary electronic controller + secondary bimetallic thermal cutoff (set at 320 °C), meeting Class III safety classification per EN 60519-2.
  • Programmable timer (0–999 minutes) enables unattended operation and reproducible thermal profiles; auto-shutdown prevents overheating during operator absence.
  • Robust stainless-steel interior chamber (SUS304) with reinforced door gasket ensures long-term corrosion resistance and thermal sealing integrity.
  • Modular shelf system supports up to nine adjustable aluminum trays (included), spaced at precise 45 mm intervals for optimal vertical thermal homogeneity.
  • Two φ28 mm exhaust ports allow optional connection to fume extraction ducts or condensation traps when processing volatile solvents.

Sample Compatibility & Compliance

The DRA430DC accommodates a broad range of sample formats—including Petri dishes, crucibles, glassware, polymer sheets, and metal coupons—within its W460 × D475 × H450 mm usable cavity. Its natural convection profile avoids turbulent airflow that may compromise fragile particulates or thin-film coatings. The unit conforms to key international regulatory frameworks: it is CE-marked per Directive 2014/30/EU (EMC) and 2014/35/EU (LVD); supports GLP-compliant documentation via external data loggers; and meets the environmental conditioning requirements outlined in USP , ISO 17025 Clause 5.4.3 (equipment verification), and ASTM E145-22 Annex A1 for gravity-convection ovens. All electrical components are rated for continuous duty at 300 °C and operate safely within ambient conditions of 5–35 °C and ≤80% RH non-condensing.

Software & Data Management

While the DRA430DC operates as a standalone instrument with an intuitive front-panel interface, it integrates seamlessly into regulated workflows through analog and digital connectivity options. A 0–10 V DC output port provides real-time temperature signal routing to external chart recorders or SCADA systems. Optional RS-485 Modbus RTU interface (available via third-party adapter kit) enables remote monitoring, setpoint adjustment, and event logging in accordance with FDA 21 CFR Part 11 requirements when paired with compliant data acquisition software. Audit trails—including start/stop timestamps, temperature deviations >±2 °C, and safety interlock triggers—are retained locally on external USB-logging devices compliant with ISO/IEC 17025 traceability guidelines.

Applications

  • Moisture content determination per AOAC 950.46 and ISO 5530-1 using gravimetric loss-on-drying protocols.
  • Pre-drying of filter papers, silica gel, and desiccants prior to analytical weighing in trace moisture analysis.
  • Conditioning of plastic specimens (e.g., ABS, PC, POM) per ISO 291 for tensile and impact testing.
  • Stabilization of reference standards and calibration weights in metrology labs.
  • Thermal aging studies of adhesives, encapsulants, and printed circuit board laminates under controlled isothermal exposure.
  • Residual solvent evaporation from pharmaceutical granules prior to tablet compression (aligned with ICH Q5C stability guidance).

FAQ

What is the maximum allowable ambient temperature for continuous operation?
The DRA430DC is rated for uninterrupted use at ambient temperatures between 5 °C and 35 °C. Operation above 35 °C may degrade PID controller stability and reduce thermal uniformity tolerance.
Can the oven be used under inert atmosphere conditions?
No—this model lacks gas inlet/outlet ports or pressure-rated seals. For nitrogen-purged applications, consider Advantec’s inert-gas-compatible DRA series with dedicated purge fittings and O₂ sensors.
Is calibration documentation included with shipment?
Each unit ships with a factory-issued calibration certificate (traceable to JCSS-accredited standards), covering temperature uniformity and controller accuracy at 100 °C, 150 °C, and 300 °C.
How often should preventive maintenance be performed?
We recommend quarterly inspection of door gasket integrity, exhaust port clearance, and thermal cutoff functionality—documented per ISO/IEC 17025 internal audit procedures.
Are additional shelves available as accessories?
Yes—aluminum and stainless-steel shelf kits (part numbers DRA-SH-A1 and DRA-SH-S1) are available separately, each supporting 15 kg load capacity per tray.