Aode Aode310 Powder Flowability Tester
| Brand | Aode |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Aode310 |
| Instrument Category | Flowability Tester |
| Measurable Powder Parameters | Flowability Index, Flow Time |
| Maximum Sample Cup Capacity | 500 mL |
| Minimum Sample Requirement | 5 mL |
Overview
The Aode Aode310 Powder Flowability Tester is a precision-engineered instrument designed for quantitative assessment of bulk powder flow behavior under gravity-driven conditions. It operates on the principle of standardized orifice flow — measuring the time required for a defined mass or volume of powder to discharge through a calibrated orifice under controlled gravitational force. This method aligns with widely adopted international test protocols including ASTM D1895 (Method A and B), ISO 4490, and USP <1174> for powder flow characterization. The device is particularly suited for quality control laboratories evaluating thermoplastic resins, polymer granules, pharmaceutical excipients, and other free-flowing particulate materials where consistent flow performance directly impacts downstream processing such as hopper feeding, pneumatic conveying, and injection molding feed consistency.
Key Features
- Two standardized test modes: Method A (mass-based, 150 ±1 g sample) and Method B (volume-based, funnel fill-and-scrape) — both compliant with ASTM D1895 and ISO 4490 requirements
- Stainless steel conical funnel with precision-machined orifice (standard 8 mm diameter, optionally configurable per user specification)
- Digital electronic timer with 0.1 s resolution and automatic start/stop trigger via optical or mechanical gate sensing
- Integrated sample cup with 500 mL capacity and volumetric graduation markings for repeatable filling
- Minimal sample requirement of only 5 mL enables efficient testing of high-value or limited-availability materials
- Modular, benchtop design with stable base and anti-vibration rubber feet to eliminate external perturbation during flow initiation
- No external power supply required for basic operation — fully mechanical gate actuation ensures reliability in field or cleanroom environments
Sample Compatibility & Compliance
The Aode310 accommodates dry, free-flowing powders and granules with particle sizes ranging from ~50 µm to 2 mm, including polyethylene (PE), polypropylene (PP), polycarbonate (PC), nylon, ABS, and engineering thermoplastics. It is not intended for cohesive, hygroscopic, or electrostatically charged materials without prior conditioning (e.g., drying, deaeration). All test procedures support GLP-compliant documentation when paired with laboratory notebooks or LIMS-integrated reporting. While the instrument itself does not carry CE or FDA certification, its methodology is referenced in FDA guidance documents for solid dosage form development and complies with ISO/IEC 17025 calibration traceability when used with NIST-traceable mass standards and certified timers.
Software & Data Management
The base Aode310 model operates without embedded firmware or proprietary software, prioritizing mechanical robustness and operational transparency. However, optional USB-timed data logging modules are available for integration with third-party data acquisition platforms (e.g., LabVIEW, MATLAB, or Excel-based QC templates). Each test sequence records timestamp, flow duration, operator ID, and test mode (A/B), supporting 21 CFR Part 11–compliant audit trails when deployed within validated GxP environments using qualified external systems. Raw flow time values can be exported in CSV format for statistical process control (SPC) analysis, capability indices (Cp/Cpk), and trend monitoring across production batches.
Applications
- Pre-shipment QC of polymer pellets entering extrusion or injection molding lines
- Batch-to-batch consistency verification for masterbatch manufacturers
- Formulation screening of plasticizer or filler effects on resin flow behavior
- Supporting DOE studies on drying temperature, particle size distribution, and surface treatment impact on flow dynamics
- Pharmaceutical granule evaluation for direct compression feasibility assessment
- Educational use in polymer science and powder technology laboratories for hands-on rheological fundamentals instruction
FAQ
What standards does the Aode310 comply with?
It supports execution of ASTM D1895 (Methods A and B), ISO 4490, and USP <1174> Annex I – Flow Through an Orifice.
Can it measure flow rate in g/s or kg/h?
No — the Aode310 outputs flow time (s) and derived qualitative flow indices; mass flow rate calculations require separate gravimetric measurement and are outside its scope.
Is calibration required before each test?
No routine calibration is needed; however, periodic verification using certified reference powders (e.g., glass beads or calibrated silica standards) is recommended per ISO/IEC 17025 internal quality procedures.
Does the instrument include a humidity or temperature sensor?
No — environmental control is external. Users must condition samples per ASTM D1895 Section 7 (ambient RH ≤ 50%, 23 ±2 °C) prior to testing.
Can the orifice size be changed?
Yes — interchangeable orifice inserts (6 mm, 8 mm, 10 mm) are available as accessories to extend dynamic range for fine or coarse powders.