Empowering Scientific Discovery

Beckman Coulter Avanti JXN-30 High-Speed Refrigerated Centrifuge

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Beckman Coulter
Origin USA
Manufacturer Type Original Equipment Manufacturer (OEM)
Product Category Imported Instrument
Model Avanti JXN-30
Instrument Type Floor-Standing Centrifuge
Speed Range 10,000–30,000 rpm
Function Refrigerated Centrifuge
Configuration Fixed-Angle Rotor System
Separation Class Cellular & Bacterial
Maximum Capacity 4.0 L
Maximum Speed 30,000 rpm
Maximum RCF 110,510 × g
Dimensions (W × D × H) 86.5 cm × 71.0 cm × 87.6 cm
Temperature Range −20 °C to +40 °C
Temperature Uniformity (after equilibrium) ±2 °C
Acceleration Profiles 10 selectable curves
Deceleration Profiles 11 selectable curves
Speed Accuracy ±10 rpm or ±0.15% (whichever is greater)
Run Time Range 1 min to 99 h 59 min (or continuous mode)

Overview

The Beckman Coulter Avanti JXN-30 High-Speed Refrigerated Centrifuge is an engineered platform for high-throughput, temperature-sensitive separation workflows in research, clinical, and regulated bioprocessing environments. Utilizing a high-torque switched-reluctance (SR) motor and precision-engineered rotor dynamics, the instrument delivers stable rotational performance up to 30,000 rpm with a maximum relative centrifugal force (RCF) of 110,510 × g. Its refrigerated chamber maintains precise thermal control between −20 °C and +40 °C, with post-equilibration uniformity within ±2 °C—critical for preserving labile macromolecules, organelles, and microbial pellets during extended runs. Designed as a floor-standing system, the Avanti JXN-30 supports large-volume processing (up to 4.0 L total capacity) while maintaining mechanical stability under high-load conditions, making it suitable for demanding applications such as subcellular fractionation, viral pellet concentration, and nucleic acid purification.

Key Features

  • High-efficiency switched-reluctance (SR) drive system reduces cycle time and improves energy efficiency without compromising torque delivery or thermal management.
  • Dynamic Rotor Inertia Check (DRIC) combined with automatic rotor recognition ensures operational safety by preventing overspeed events—even when rotors are interchanged across instruments or user sessions.
  • Triple-layer safety architecture: (1) electromechanical lid interlock prevents access during rotation; (2) reinforced steel rotor chamber contains potential failures; (3) real-time imbalance detection halts operation within milliseconds upon deviation from rotational symmetry.
  • Intuitive touchscreen interface with dual-parameter display shows both setpoints and real-time values simultaneously—including speed, RCF, temperature, time remaining, and acceleration/deceleration status.
  • Flexible run programming: 10 acceleration and 11 deceleration profiles support optimized pelleting and gradient integrity; delay start enables unattended initiation; continuous mode accommodates long-duration protocols requiring reproducible endpoint conditions.

Sample Compatibility & Compliance

The Avanti JXN-30 accommodates a broad range of fixed-angle rotors compatible with standard conical-bottom tubes (e.g., 50 mL, 250 mL), bottles (up to 1 L), and specialized vessels used in cell culture harvest and bioprocess clarification. Its design conforms to IEC 61010-1 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) and meets electromagnetic compatibility (EMC) standards per IEC 61326-1. For laboratories operating under quality systems, the instrument supports audit-ready data handling aligned with FDA 21 CFR Part 11 requirements when paired with optional compliant software modules—enabling electronic signatures, secure user authentication, and immutable audit trails for method execution and parameter changes.

Software & Data Management

Network-enabled operation allows remote monitoring via Ethernet or Wi-Fi, including live status updates, email-based alerts for completion or fault conditions, and centralized fleet management across multiple instruments. Up to 100 customizable protocols can be stored locally or synchronized across networked devices. Real-time graphical plotting displays RCF, temperature, and rotor speed throughout the run, while timestamped event logs capture all critical parameters—including rotor ID, operator login, environmental deviations, and error codes. Data export complies with CSV and XML formats for integration into LIMS or ELN platforms, supporting GLP/GMP documentation workflows in shared core facilities and contract development and manufacturing organizations (CDMOs).

Applications

  • Isolation of mitochondria, lysosomes, and other subcellular organelles from mammalian and plant tissues.
  • Concentration and purification of bacteriophages, lentiviral vectors, and extracellular vesicles (EVs) for therapeutic development.
  • Routine harvesting of bacterial and yeast cultures at industrial scale, including cryopreserved stock preparation.
  • Preparative ultracentrifugation steps preceding analytical SEC-MALS or cryo-EM sample preparation.
  • Quality control testing in biologics manufacturing, including particulate analysis and aggregate removal verification per USP and .

FAQ

What rotor types are certified for use with the Avanti JXN-30?
The instrument is validated for use with Beckman Coulter’s full suite of fixed-angle rotors, including the Type 70 Ti, Type 45 Ti, and JA-25.50 series—each individually calibrated and rated for specific maximum speeds and load configurations.
Does the Avanti JXN-30 support regulatory-compliant data archiving?
Yes—when configured with optional Compliance Software and connected to a validated network infrastructure, the system supports 21 CFR Part 11–compliant audit trails, role-based access control, and electronic signature capability.
How does the DRIC system enhance operational safety?
DRIC continuously monitors rotor inertia during spin-up and compares it against factory-stored rotor-specific profiles; any mismatch triggers immediate deceleration, preventing misuse of damaged, mislabeled, or non-certified rotors.
Can the centrifuge operate continuously for extended periods?
Yes—the timer supports indefinite runtime (continuous mode), and the thermally managed refrigeration system maintains stable cavity temperature over multi-hour runs without compressor cycling-induced vibration.
Is remote diagnostics available for service support?
Field-service engineers may initiate secure remote diagnostic sessions through Beckman Coulter’s authorized service portal, provided the instrument is connected to a corporate network with appropriate firewall permissions.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0