Boante BAT50/100/150/250-JGF Precision Forced-Air Constant-Temperature Drying Oven
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT50/100/150/250-JGF |
| Temperature Range | RT+10°C to 250°C |
| Temperature Uniformity | ±2% of setpoint |
| Temperature Fluctuation | ±1°C |
| External Dimensions (W×D×H) | 555×495×820 mm (BAT50-JGF) |
| Internal Dimensions (W×D×H) | 350×370×395 mm (BAT50-JGF) |
| Interior Material | Mirror-Finish Stainless Steel |
| Control System | LCD Color Touch Controller with PID Algorithm |
| Sensor | PT100 Platinum Resistance Thermometer |
| Air Circulation | Horizontal Forced-Air Convection with Three-Speed Adjustable Centrifugal Blower |
| Safety Features | Independent Over-Temperature Cut-Off, Audible/Visual Alarm |
| Optional Accessories | USB Data Logging, RS485 PC Interface, 5-inch Programmable Touch Controller, Remote Monitoring via WeChat Mini Program |
Overview
The Boante BAT-Series Precision Forced-Air Constant-Temperature Drying Oven is engineered for laboratories requiring stable, repeatable thermal environments for drying, baking, sterilization, and moisture content determination. Utilizing a horizontal forced-air convection system with a centrifugal blower, the oven ensures rapid thermal recovery after door opening and uniform temperature distribution across the entire chamber—critical for compliance-driven applications in pharmaceutical QC, materials science, and academic research. The core thermal control architecture integrates a microprocessor-based PID algorithm with a high-stability PT100 sensor, minimizing overshoot and maintaining setpoint accuracy within ±1°C fluctuation and ±2% uniformity (relative to setpoint) across the working volume. Designed to meet foundational laboratory safety and operational standards, the BAT-Series supports GLP-aligned workflows through configurable logging, audit-ready event alerts, and hardware-level over-temperature protection.
Key Features
- Mirror-finish stainless steel interior chamber with seamless, radius-corner construction—resistant to corrosion and optimized for cleaning validation and residue-free operation.
- Three-speed adjustable horizontal airflow system: enables precise optimization of heat transfer dynamics for diverse sample types—from delicate polymer films to dense ceramic powders.
- Full-color LCD touch controller with real-time parameter display, programmable timer (0–9999 min or 0–999 h), and dual-mode operation (constant temperature or time-based ramp/soak profiles).
- Double-layer tempered glass observation window with reinforced sealing—maintains thermal integrity while enabling non-intrusive visual monitoring without compromising chamber stability.
- Isolated hinge design with silicone gasket seal and mechanical latch handle—ensures consistent compression force and long-term sealing performance under repeated thermal cycling.
- Independent mechanical over-temperature cut-off switch (non-software dependent), plus audible/visual alarm triggered upon deviation exceeding user-defined thresholds.
Sample Compatibility & Compliance
The BAT-Series accommodates standard laboratory vessels including Petri dishes, weighing bottles, crucibles, and aluminum pans—compatible with ASTM E145, ISO 5725, and USP guidelines for loss-on-drying (LOD) assays. Its uniform airflow pattern and low thermal mass chamber minimize localized hot/cold spots, supporting reproducible moisture analysis per AOAC 950.46 and pharmacopeial drying protocols. While not certified for Class I Div 1 hazardous locations, the oven complies with IEC 61010-1 safety requirements for laboratory electrical equipment. All models feature grounding continuity, double insulation on heating elements, and fail-safe thermal fusing—meeting baseline GMP facility acceptance criteria for auxiliary lab instrumentation.
Software & Data Management
The embedded controller supports optional data export via USB flash drive (CSV format) and real-time serial communication via RS485 interface (Modbus RTU protocol) for integration into centralized Lab Information Management Systems (LIMS). When equipped with the 5-inch programmable touch module, users can define multi-step temperature profiles, assign operator IDs, and generate timestamped run logs—including start/stop times, setpoint deviations, and alarm events. Remote supervision is enabled through an authenticated WeChat Mini Program interface, delivering push notifications for alarm conditions and historical temperature trend previews—without requiring on-site network infrastructure. All data records include immutable timestamps and support 21 CFR Part 11-compliant electronic signature add-ons when deployed with validated third-party software platforms.
Applications
- Moisture content analysis in raw materials (e.g., APIs, excipients, food ingredients) per pharmacopeial drying methods.
- Pre- and post-weighing desiccation of filter papers, gravimetric filters, and ashless crucibles in environmental testing labs.
- Thermal conditioning of calibration standards, reference materials, and humidity-sensitive sensors prior to metrological verification.
- Baking of printed circuit board (PCB) substrates and composite laminates during R&D prototyping cycles.
- Stabilization and outgassing of optical components and vacuum chamber internals before high-vacuum processing.
- Accelerated aging studies of packaging films and adhesives under controlled thermal stress conditions.
FAQ
What is the maximum operating temperature for the BAT250-JGF model?
The BAT250-JGF is rated for continuous operation up to 250°C, with thermal stability maintained per its specified fluctuation and uniformity tolerances.
Can the oven be validated for IQ/OQ/PQ protocols?
Yes—the combination of PT100 sensing, PID control repeatability, mechanical safety interlocks, and optional data logging enables full qualification against ISO/IEC 17025 and GxP requirements when supported by documented procedures and calibrated traceable references.
Is the internal chamber volume fully usable for stacking samples?
The stated internal dimensions reflect net usable space; however, optimal airflow requires ≥25 mm clearance around all sides of loaded shelves. Recommended loading density is ≤70% of total shelf area to preserve thermal homogeneity.
Does the oven support ramp-and-soak programming?
Ramp-and-soak functionality is available only with the optional 5-inch programmable touch controller—not the base LCD module.
What maintenance intervals are recommended for the circulation blower?
Under normal use (≤8 hrs/day, ambient ≤30°C), the centrifugal blower requires inspection every 12 months; bearing lubrication is factory-sealed and non-serviceable—replacement is recommended at 5-year intervals or upon audible vibration increase.