Empowering Scientific Discovery

Bruker Globulyser Fat Globule Size Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Bruker
Origin Germany
Manufacturer Type Authorized Distributor
Product Origin Imported
Model Globulyser
Detection Target Milk Fat Globule Size Distribution
Automation Level Fully Automatic
Analysis Time 1–5 minutes per sample
Size Range 0.20–3.0 µm (mean diameter)
Accuracy ±2–4% of reading

Overview

The Bruker Globulyser Fat Globule Size Analyzer is a purpose-built, benchtop optical instrument engineered for rapid, operator-independent determination of mean fat globule diameter in liquid and reconstituted dairy products. It operates on the principle of dual-signal optical detection—simultaneously measuring transmitted light intensity and forward-scattered light intensity at low angles (<15°) through a standardized flow cell. Since forward scattering intensity scales monotonically with particle size in the sub-micron to low-micron range (per Mie theory approximations), the ratio of scattered-to-transmitted signal provides a robust, calibration-based metric for mean globule size. Unlike laser diffraction or dynamic light scattering systems, the Globulyser does not require dilution, refractive index matching, or complex dispersion protocols—enabling direct analysis of raw milk, UHT milk, pasteurized fluid milk, cream, reconstituted skim milk powder (SMP), whole milk powder (WMP), and anhydrous milk fat (AMF) solutions without pre-filtration or sonication. Its design reflects over 25 years of co-development with global dairy processors and central quality laboratories, prioritizing repeatability under routine production-line conditions rather than theoretical resolution limits.

Key Features

  • Fully automated measurement cycle—including auto-zeroing, sample aspiration, optical readout, post-measurement cell flush, and air-drying—executed in ≤5 minutes per sample
  • Integrated optical path with temperature-stabilized LED source and dual photodiode detection for long-term signal stability
  • No consumables beyond standard cleaning solutions; minimal moving parts (single peristaltic pump and solenoid valves) ensure >98% operational uptime
  • Self-diagnostic firmware continuously monitors flow integrity, optical baseline drift, and detector saturation thresholds
  • CE-marked and compliant with IEC 61000-6-2/6-3 for electromagnetic compatibility in industrial laboratory environments
  • Designed for GLP-aligned workflows: all measurements are timestamped, user-ID logged, and raw signal data retained in immutable binary format

Sample Compatibility & Compliance

The Globulyser accepts undiluted liquid samples (raw milk, homogenized milk, cream, UHT-treated beverages) and reconstituted powders (WMP, SMP, whey protein concentrate solutions) at concentrations up to 12% w/v total solids. Samples containing >0.5% added plant-based fats (e.g., coconut oil blends) are compatible provided emulsifier systems remain stable during analysis time. The system meets ISO 5725-2:2019 guidelines for intermediate precision in routine testing and supports method validation per ISO 17025:2017 requirements. While not FDA 21 CFR Part 11–certified out-of-the-box, audit trails, electronic signatures, and data export controls can be configured to align with GMP documentation practices for dairy QA/QC departments.

Software & Data Management

Operation is managed via an embedded Linux-based controller with a 7-inch capacitive touchscreen interface. The proprietary Globulyser Control Software (v4.x) enables method storage (up to 32 user-defined protocols), real-time signal visualization, batch reporting (CSV/PDF), and trend charting across shifts. All measurement events—including calibration logs, maintenance alerts, and error codes—are stored locally with SHA-256 hashed integrity verification. Data export supports SFTP, USB mass storage, and OPC UA connectivity for integration into MES or LIMS platforms. Raw photodiode voltage traces (10 kHz sampling) are archived alongside calculated mean diameter values, permitting retrospective reprocessing if updated calibration curves become available.

Applications

  • Optimization of high-pressure homogenizer settings to reduce energy consumption while maintaining target globule size distribution (D[3,2] ≤ 2.0 µm)
  • Stability assessment of extended-shelf-life products (UHT, ESL milk) by tracking globule coalescence kinetics over accelerated storage trials
  • Quantification of free fat content in milk powders via dissolution-phase analysis—correlating elevated D[3,2] with surface fat migration risk in infant formula
  • Verification of homogenization efficiency after equipment maintenance or process changeovers (e.g., new homogenizer valve sets)
  • Raw material screening of incoming milk lots to detect abnormal native globule size distributions indicative of mastitis or seasonal lactation shifts
  • Supporting R&D of novel dairy analogs (e.g., oat-milk blends) where fat globule mimicry impacts mouthfeel and oxidative stability

FAQ

Does the Globulyser require daily recalibration?
No. Factory calibration is traceable to NIST-traceable polystyrene latex standards (0.5 µm and 2.0 µm). A single weekly verification using the supplied reference suspension is sufficient for routine operation.
Can it measure bimodal or polydisperse distributions?
The Globulyser reports only the volume-weighted mean diameter (D[3,2]). It is not designed for full distribution deconvolution; users requiring D10/D50/D90 must employ complementary techniques such as laser diffraction or microscopy.
Is cleaning validated between samples?
Yes. Each cycle includes a 30-second rinse with deionized water followed by 15 seconds of compressed air purge. Residue testing per AOAC 991.23 confirms <0.1% carryover for consecutive high-fat samples.
What maintenance intervals are recommended?
Pump tubing replacement every 6 months; optical window inspection quarterly; full system performance verification annually by Bruker-certified service engineers.
Is remote diagnostics supported?
Yes—via secure TLS-encrypted VNC connection with prior customer authorization; enabled only during scheduled support windows per ISO/IEC 27001-aligned access policies.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0