Empowering Scientific Discovery

Bruker MOVE-T FT-NIR Liquid Dairy Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Bruker
Origin Germany
Model MOVE-T
Instrument Type Laboratory
Principle Fourier Transform Near-Infrared (FT-NIR)
Design Benchtop, Flow-Through Configuration
Sample Form Liquid dairy matrices only
Compliance Context Designed for routine QC in dairy processing per ISO 9622:2013, IDF 141:2000, and AOAC Official Method 972.16

Overview

The Bruker MOVE-T FT-NIR Liquid Dairy Analyzer is a purpose-built benchtop spectrometer engineered for rapid, non-destructive quantitative analysis of liquid dairy products using Fourier Transform Near-Infrared (FT-NIR) spectroscopy. Unlike dispersive NIR systems, the MOVE-T employs a Michelson interferometer with a high-stability solid-state laser reference, delivering superior wavelength accuracy (10,000:1 at 100 scans). Its optical architecture is optimized for transmission measurement in the 10,000–4,000 cm⁻¹ spectral range (1,000–2,500 nm), enabling robust calibration models for fat, protein, lactose, moisture, and total solids—parameters critical for raw milk acceptance, pasteurized product release, and process intermediate monitoring. The system operates without consumables or sample preparation beyond standard homogenization, aligning with lean laboratory workflows and GLP-compliant dairy quality control environments.

Key Features

  • Compact FT-NIR platform with integrated interferometer and InGaAs detector cooled thermoelectrically to –10 °C for reduced dark current drift
  • Dual-path fluidic handling system: software-selectable switching between high-shear homogenizing pump (for viscous yogurts, cream-based blends) and low-pulsation peristaltic pump (for skim milk, whey, standardized blends)
  • Wear-resistant quartz flow cell with 1-mm pathlength and chemically inert wetted surfaces; validated for >50,000 cycles without performance degradation
  • Automated rinse-and-purge sequence between samples using deionized water or ethanol, minimizing carryover and ensuring baseline reproducibility
  • Self-calibrating optical alignment with real-time interferogram monitoring; no manual mirror adjustment required during daily operation
  • IP54-rated enclosure suitable for controlled laboratory or near-production-line deployment

Sample Compatibility & Compliance

The MOVE-T is validated exclusively for liquid dairy matrices—including raw bovine milk, standardized milk, UHT-treated fluids, sweetened condensed milk, cultured buttermilk, and yogurt base slurries (≤12% solids, ≤10,000 mPa·s viscosity). It excludes powdered, frozen, or particulate-laden samples. Calibration models are developed and maintained per ISO 12099:2017 (animal feeding stuffs and milk) and aligned with the European Reference Laboratory for Milk Quality (EURL-MQ) validation framework. Data integrity complies with FDA 21 CFR Part 11 requirements via audit-trail-enabled software, electronic signatures, and secure user role management. Routine performance verification follows ASTM E1655-22 (standard practices for NIR quantitative analysis) and internal SOPs traceable to ISO/IEC 17025:2017.

Software & Data Management

Operation is managed through OPUS Quant 8.5 software, featuring method-driven workflow templates, multivariate calibration tools (PLS-1/PLS-2), and automated outlier detection based on spectral residual and Hotelling’s T² statistics. All spectra, prediction results, and instrument logs are stored in encrypted SQLite databases with configurable retention policies. Export options include CSV, XML, and LIMS-compatible ASTM E1384 format. Remote diagnostics and firmware updates are supported via TLS-secured HTTPS channel; no cloud storage is used unless explicitly enabled by site administrator under GxP-controlled configuration.

Applications

  • Raw milk intake testing at dairy collection centers (fat/protein grading per national pricing schemes)
  • In-process verification of standardized milk blends pre-pasteurization
  • Final product release testing for shelf-stable UHT milk and flavored dairy beverages
  • QC screening of starter cultures and fermentation intermediates in yogurt production
  • Supplier qualification audits requiring rapid, portable-grade NIR data traceability
  • Research applications involving thermal stability studies or enzymatic hydrolysis kinetics in liquid matrices

FAQ

Does the MOVE-T require daily external calibration standards?
No. The system performs internal reference validation using a built-in polystyrene film standard before each analytical batch; user-provided calibration sets remain stable for ≥6 months under controlled lab conditions.
Can it analyze ultra-high-viscosity products like Greek yogurt or quark?
Not directly—it requires dilution or mechanical shearing prior to injection; the homogenizing pump supports up to 10,000 mPa·s, but undiluted quark exceeds flow cell design limits.
Is spectral data export compatible with third-party chemometrics platforms?
Yes. Raw interferograms (.0, .1 files) and processed absorbance spectra (.spc, .jdx) are fully accessible; PLS model objects can be exported as .mat or .xml for MATLAB or Unscrambler interoperability.
What maintenance intervals are recommended?
Optical alignment verification every 6 months; flow cell inspection and O-ring replacement annually; no lamp or grating servicing required due to solid-state interferometer architecture.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0