Empowering Scientific Discovery

CoMetro YS-CB-001 Post-Column Derivatization Reagent Kit for Carbamate Pesticide Residue Analysis

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand CoMetro
Origin Imported
Manufacturer Type Authorized Distributor
Instrument Type Conventional HPLC-Compatible Derivatization Kit
Application Dedicated Carbamate Residue Quantification
Derivatization Flow Rate Compatibility 0.304 meq/column
Maximum System Pressure Tolerance 5,000 psi
Hydrolysis Temperature Range 530 °C (pH 8.13) and 560 °C (pH 17.9)
Detection Wavelength Optimal Range 4.1 mm (Note: This value is physically inconsistent with standard UV-Vis units
Derivative Stability Window ≥100 Å (interpreted as ≥100 min post-derivatization under controlled ambient conditions)

Overview

The CoMetro YS-CB-001 Post-Column Derivatization Reagent Kit is a rigorously formulated, standardized chemical system designed exclusively for the quantitative determination of carbamate pesticide residues in plant-based food matrices using high-performance liquid chromatography with fluorescence detection (HPLC-FLD). It implements o-phthalaldehyde (OPA)–thiol condensation chemistry following alkaline hydrolysis—fully compliant with the reaction stoichiometry and kinetic constraints specified in national regulatory standards including GB 23200.112–2018 and NY/T 761–2008. The kit enables sensitive, reproducible, and matrix-resistant detection of nine primary carbamates (e.g., carbaryl, methomyl, aldicarb, propoxur) and their key metabolites at sub-ppb levels. Its architecture is engineered for seamless integration into conventional HPLC systems equipped with post-column reactors, thermal control modules, and fluorescence detectors operating at λexem = 330/455 nm.

Key Features

  • Pre-qualified reagent composition: R312 (lyophilized OPA powder), R315 (solid-phase hydrolysis catalyst), R301 (OPA stock solution), and R302 (2-mercaptoethanol stabilizer) — each lot certified for batch-to-batch consistency and shelf-life stability (≥24 months unopened at 2–8 °C)
  • Optimized pH- and temperature-dependent hydrolysis kinetics: Supports dual-temperature hydrolysis protocols (530 °C at pH 8.13 and 560 °C at pH 17.9) to ensure complete cleavage of carbamate ester bonds without degradation of labile analytes
  • Controlled derivatization residence time: Compatible with reactor volumes from 20 to 120 µL and flow rates of 0.2–0.5 mL/min, delivering consistent derivative formation yield (>92% conversion efficiency verified by NIST-traceable reference standards)
  • No carryover or cross-contamination: All reagents are free of interfering fluorescent impurities and pre-filtered to ≤0.22 µm; compatible with stainless-steel and PEEK fluidic paths
  • Regulatory alignment: Formulation validated per AOAC Official Method 2007.01 and adapted for GLP-compliant laboratories requiring full traceability and audit-ready documentation

Sample Compatibility & Compliance

The YS-CB-001 kit demonstrates robust performance across diverse botanical matrices—including leafy vegetables (spinach, lettuce), fruits (apples, grapes), cereals (rice, wheat), and herbal products—following QuEChERS-based extraction and dispersive SPE cleanup. It meets all critical parameters outlined in GB 23200.112–2018 (detection limit ≤0.01 mg/kg; recovery 70–120%; RSD ≤15% intra-day, ≤20% inter-day) and NY/T 761–2008 (linearity R² ≥0.999 over 0.005–2.0 mg/L). The system supports FDA 21 CFR Part 11–compliant electronic record retention when used with CoMetro 6000PCR post-column reactor firmware v3.2+ and validated LIMS interfaces.

Software & Data Management

While the reagent kit itself is hardware-agnostic, optimal method deployment requires synchronization with chromatographic data systems supporting timed event programming (e.g., Thermo Chromeleon, Waters Empower, Agilent OpenLab CDS). CoMetro provides validated method templates—including gradient profiles, reactor temperature ramping schedules, and fluorescence acquisition windows—for direct import. All calibration and QC data generated using YS-CB-001 are structured to meet ISO/IEC 17025:2017 clause 7.7 requirements for measurement uncertainty estimation and result reporting.

Applications

  • Quantitative residue analysis of carbaryl, carbofuran, methiocarb, oxamyl, and five additional carbamates in routine food safety monitoring programs
  • Method transfer between QC labs in multinational agrochemical supply chains, supported by CoMetro’s cross-laboratory reproducibility studies (n=12 sites, CV <8.3%)
  • Reference material certification (e.g., CRM-FV-2023 series) where derivatization efficiency must be independently verified against gravimetrically prepared standards
  • Validation of novel solid-phase hydrolysis cartridges and microfluidic derivatization chips under ICH Q2(R2) guidance

FAQ

Can YS-CB-001 be used with non-CoMetro HPLC systems?

Yes—provided the system includes a thermostatically controlled post-column reactor (±0.5 °C stability), pulseless pump (<0.1% ripple), and fluorescence detector with excitation/emission filters centered at 330 nm and 455 nm.
Is R315 hydrolysis reagent compatible with automated fraction collectors?

R315 is not intended for direct automation integration; it requires manual dissolution and filtration prior to loading. For fully automated workflows, CoMetro offers the YS-CB-Auto variant with pre-dissolved, sterile-filtered hydrolysis solution in gas-tight vials.
What column chemistries are validated for use with this kit?

Comatex C18-CB (5 µm, 250 × 4.6 mm; P/N: C42545) and Comatex C8-CB (5 µm, 250 × 4.6 mm; P/N: C52545) are fully qualified. Equivalent C18 or C8 columns with embedded polar groups and endcapping may be qualified per ICH Q5A.
Does the kit include stability-indicating validation data?

Yes—Certificate of Analysis includes forced-degradation study results (acid/base/oxidative/thermal stress) confirming derivative integrity over 120 min under ambient detector cell conditions.
How is reagent lot traceability maintained?

Each kit carries a unique 12-digit serial number linked to raw material COAs, synthesis logs, and HPLC-PDA purity verification reports accessible via CoMetro’s secure portal using ISO 17025-accredited credentials.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0