Empowering Scientific Discovery

Crystal HPC40 Series Handheld Pressure and mA Loop Calibrator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Crystal
Origin Denmark
Model HPC40 Series
Pressure Range Up to 15,000 psi (1000 bar / 100 MPa)
Accuracy ±0.035% of reading
Operating Temperature Compensation Full-range compensation from −20 °C to +50 °C
Functionality Simultaneous pressure measurement & mA loop sourcing/sinking (0–24 mA), voltage measurement (0–30 VDC), temperature measurement via Pt100/Pt1000 (True Ohms mode)
Interface Menu-free, direct-access button layout
Power Options Rechargeable Li-ion battery with AC adapter
Design Modular, field-serviceable architecture
Calibration Targets Analog and digital pressure gauges, transmitters, switches, and I/P converters
Compliance Designed for traceable calibration in accordance with ISO/IEC 17025, ASTM E74, and EN 837-1

Overview

The Crystal HPC40 Series Handheld Pressure and mA Loop Calibrator is an engineered precision instrument designed for field and workshop-based calibration of pressure instrumentation and 4–20 mA current loops. It operates on the principle of high-stability quartz-resonator-based pressure sensing combined with precision analog-to-digital conversion and active thermal compensation across its full operating range (−20 °C to +50 °C). Unlike conventional calibrators that apply fixed temperature corrections at discrete points, the HPC40 implements continuous, real-time thermal modeling of sensor drift and electronics offset—ensuring metrological integrity without user intervention. Its dual-function architecture integrates a primary pressure transducer (capable of gauge, absolute, and differential modes) with a fully isolated, programmable current source/sink and high-impedance voltage measurement circuitry. This eliminates the need for separate instruments during transmitter loop verification, zero/span adjustment, or HART-compatible device commissioning.

Key Features

  • Full-range thermal compensation: Real-time correction algorithms maintain ±0.035% of reading accuracy across −20 °C to +50 °C ambient conditions—critical for calibration consistency in uncontrolled environments such as offshore platforms or outdoor process plants.
  • Integrated mA loop functionality: Measures and sources/sinks 0–24 mA with <±0.01% of reading accuracy; supports live loop power (24 VDC internal supply) or external loop powering with simultaneous measurement—enabling two-wire transmitter testing without auxiliary power supplies.
  • True Ohms resistance measurement: Dedicated low-noise, four-wire Pt100/Pt1000 input channel using true ohmic excitation (not constant-current approximation), delivering <±0.05 °C uncertainty in temperature verification tasks aligned with IEC 60751 Class A tolerances.
  • Modular hardware architecture: Field-replaceable sensor modules, battery packs, and interface boards allow configuration-specific upgrades and reduce mean time to repair (MTTR) under ISO/IEC 17025 maintenance protocols.
  • Menu-free operational interface: Direct-access keys for pressure units (psi, bar, kPa, MPa, inH₂O, mmHg), mA scaling (0–100%), and function toggling eliminate navigation latency—essential during time-sensitive field audits or plant turnaround activities.
  • Non-volatile screen memory: Stores up to 20 previously configured display layouts—including custom unit combinations, offset values, and loop test presets—for rapid recall without reconfiguration.

Sample Compatibility & Compliance

The HPC40 Series is validated for calibration of analog and smart pressure instruments including Bourdon-tube gauges, diaphragm seals, piezoresistive transmitters, and capacitance-based differential pressure cells. It supports verification of mechanical pressure switches (SPDT/DPDT), electronic pressure relays, and I/P converters per ISA-51.1 and EN 837-1 mechanical gauge standards. All factory calibrations are traceable to NIST, DKD, or UKAS-accredited laboratories, with documented uncertainty budgets provided per ISO/IEC 17025 requirements. The device meets EMC immunity per IEC 61326-1 (industrial environment) and carries CE, UKCA, and RoHS markings. For regulated industries, audit-ready calibration records—including operator ID, timestamp, environmental conditions, and pass/fail flags—can be exported via USB-C to CSV or PDF formats compliant with FDA 21 CFR Part 11 data integrity expectations when used with validated software workflows.

Software & Data Management

No proprietary desktop application is required for basic operation; however, optional Crystal Link PC software enables automated calibration certificate generation, deviation trending, and uncertainty propagation analysis per GUM (JCGM 100). Data export supports .csv, .xlsx, and XML formats compatible with LIMS integration. Firmware updates are delivered via signed binary packages verified through SHA-256 checksums and ECDSA signatures to ensure integrity. Internal memory logs all measurement events with UTC timestamps, battery state, and sensor health diagnostics—supporting GLP/GMP-compliant record retention for ≥12 months without external storage.

Applications

  • Field verification of pressure safety valves (PSVs) and relief device setpoints in petrochemical refineries.
  • Commissioning and loop-checking of Rosemount, Endress+Hauser, and WIKA smart transmitters in pharmaceutical clean utilities (PW, WFI, SIP).
  • Periodic calibration of HVAC static pressure sensors in ISO Class 5–8 cleanrooms per ISO 14644-3 Annex B.
  • Validation of pressure-controlled bioreactor manifolds in cell therapy manufacturing facilities.
  • Supporting ISO/IEC 17025 accredited calibration labs performing accredited pressure calibrations up to 100 MPa.

FAQ

Is the HPC40 Series suitable for calibrating digital pressure transmitters with HART protocol?
Yes—it provides stable mA sourcing and precise voltage measurement required for analog signal verification. While it does not interpret HART digital commands, it serves as the primary reference for the 4–20 mA analog output during HART device characterization and loop integrity testing.

Can the internal 24 VDC supply power high-load industrial transmitters?
The internal loop supply delivers up to 24 VDC at 30 mA continuous, sufficient for most two-wire transmitters. For higher-power devices (e.g., certain radar level transmitters), external loop powering with simultaneous measurement is supported.

How is traceability maintained during field use?
Each unit ships with a Certificate of Calibration valid for 12 months, referencing national standards. Users may perform interim checks using certified pressure references; documented check results satisfy ISO/IEC 17025 intermediate verification requirements.

Does the modular design support future sensor upgrades?
Yes—pressure sensor modules are mechanically and electrically standardized. Customers may upgrade from gauge to absolute or differential configurations by swapping modules and loading corresponding firmware—no recalibration at the OEM level is required.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0