Empowering Scientific Discovery

HUANKONG GHK-1200 Environmental Air Integrated Sampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Origin Shandong, China
Manufacturer Type Manufacturer
Product Category Domestic
Model GHK-1200
Instrument Type 24-Hour Constant-Temperature & Constant-Flow Gas Sampler
Instrument Architecture Multi-Channel Gas Sampler
Particle Sampling Flow Range 10–130 L/min
Display High-Brightness Wide-Temperature Color Touchscreen
Data Storage Capacity >100,000 records
Power Options AC Adapter or Optional Built-in Rechargeable Lithium Battery (≥4 h runtime)
Environmental Protection Rating IP54-equivalent dust and water resistance
Compliance Standards HJ 618–2011, HJ 656–2013, HJ 93–2013, HJ/T 374–2007, HJ/T 375–2007, HJ/T 376–2007, JJG 956–2013, JJG 943–2011, HJ 955–2018, HJ 657–2013, HJ 644–2013, HJ 583–2010
Data Output Bluetooth thermal printing + USB flash drive export
Sampling Pump Imported diaphragm pump with high load capacity, low noise, and long service life
Real-Time Compensation Automatic measurement of pre-meter temperature and pressure
Structural Material Anodized aluminum sampling head with anti-static surface treatment

Overview

The HUANKONG GHK-1200 Environmental Air Integrated Sampler is an engineered solution for regulatory-grade ambient and indoor air quality monitoring in compliance with Chinese national and environmental protection industry standards. Designed around dual-sampling principles—solution absorption for gaseous pollutants (e.g., SO₂, NOₓ, NH₃, H₂S, ozone-reactive species) and filter-based gravimetric collection for particulate matter—the GHK-1200 supports simultaneous or sequential operation across multiple sampling modes. Its architecture implements laminar-flow-controlled, constant-temperature and constant-flow sampling per HJ/T 376–2007 and JJG 956–2013, ensuring metrological traceability for volumetric flow rates under varying ambient conditions. The instrument operates on the principle of calibrated volumetric displacement using a precision diaphragm pump, with real-time thermobarometric compensation to compute standardized sampling volumes at 273.15 K and 101.325 kPa—critical for mass concentration calculations required by HJ 618–2011 and HJ 656–2013.

Key Features

  • Multi-mode sampling flexibility: Independent configuration of medium-flow (e.g., PM₁₀/PM₂.₅), low-flow heated (for volatile organic compounds or moisture-sensitive analytes), low-flow thermostatically controlled (±0.5 °C), and ultra-low-flow (e.g., SVOC or fluorides) channels—each with dedicated flow control and real-time feedback.
  • High-reliability sampling train: Imported diaphragm pump delivering stable flow performance across backpressures up to 25 kPa, with acoustic noise 10,000 hours.
  • Intelligent environmental compensation: Integrated Pt100 temperature sensor and piezoresistive pressure transducer continuously monitor inlet conditions; microprocessor applies ISO 10780-derived algorithms for dry-standard-volume conversion.
  • Dual-input human interface: Capacitive touchscreen (5.7″, 800×480 resolution) with glove-compatible responsiveness, supplemented by tactile membrane keys for operation in low-visibility or cold-weather field deployments.
  • Ruggedized mechanical design: Anodized aluminum sampling head with electrostatic-dissipative surface finish (surface resistivity <10⁹ Ω/sq); chassis rated to IP54-equivalent ingress protection per IEC 60529—validated for continuous operation in rain, snow, and high-humidity environments.
  • Power resilience: AC-powered primary operation with optional internal Li-ion battery pack supporting ≥4 hours of uninterrupted sampling at 100 L/min; auto-resume functionality preserves time-stamped flow logs and accumulated volume metrics after power interruption.

Sample Compatibility & Compliance

The GHK-1200 accommodates standardized sampling media per Chinese EPA methodologies: 47-mm quartz or PTFE filters for PM₁₀/PM₂.₅ gravimetric analysis (HJ 618–2011); alkali-coated filters for fluoride collection (HJ 955–2018); Teflon-coated glass fiber filters for heavy metals (HJ 657–2013); and polyurethane foam (PUF)/XAD-2 resin cartridges for semi-volatile organic compounds (SVOCs) per HJ 644–2013. For gaseous species, it interfaces with impingers containing absorbing solutions (e.g., NaOH for SO₂, KMnO₄ for ozone) compliant with HJ/T 375–2007. All flow paths are chemically inert (PTFE tubing, stainless-steel valves), minimizing adsorption artifacts. The system meets electromagnetic compatibility requirements per GB/T 18268.1–2010 (IEC 61326-1), ensuring reliable operation near radio transmitters or industrial variable-frequency drives.

Software & Data Management

Onboard firmware implements non-volatile flash memory storage (>100,000 timestamped records), each containing date/time, actual and standard flow rates, accumulated volume, temperature, pressure, pump duty cycle, and error flags. Data export follows two validated pathways: Bluetooth 4.2 LE connection to certified thermal printers (supporting ISO/IEC 19794-5-compliant print formats) or encrypted USB 2.0 transfer with CSV-formatted datasets compatible with LIMS platforms. Audit trails include operator ID (optional RFID badge integration), method selection, calibration history, and power-event logs—supporting GLP-aligned data integrity per CNAS-CL01:2018 requirements. Firmware updates are performed via signed binary packages to prevent unauthorized modification.

Applications

The GHK-1200 serves as a primary sampling platform for municipal environmental monitoring stations, third-party testing laboratories accredited to CMA (China Metrology Accreditation), and occupational hygiene units conducting workplace air assessments per GBZ 159–2004. It is routinely deployed in national air quality surveillance networks (e.g., China National Environmental Monitoring Centre’s routine monitoring program), source emission characterization studies, indoor air quality audits in schools and hospitals (per GB/T 18883–2022), and research on atmospheric deposition chemistry—including fluorides in agricultural zones and trace metal enrichment in urban aerosols. Its modular airflow architecture also enables method development for emerging contaminants such as PFAS precursors or oxygenated VOCs requiring customized residence times and thermal management.

FAQ

Does the GHK-1200 comply with international standards such as ISO or ASTM?
While primarily designed to meet Chinese environmental standards (HJ, JJG, GB/T series), its flow control accuracy (±2% full scale), thermobarometric compensation methodology, and gravimetric sampling protocols align with core principles in ISO 7708 (inhalable particles), ISO 12103-1 (test dust), and ASTM D1357 (ambient air sampling). Full ISO/IEC 17025 validation requires site-specific uncertainty budgeting.
Can the instrument be used for PM₂.₅ sampling in high-humidity environments?
Yes—the optional heated inlet module (available as accessory) maintains inlet temperature ≥30 °C to suppress water condensation on filters, satisfying HJ 656–2013 requirements for humidity-corrected mass determination.
Is remote monitoring or telemetry supported?
The base configuration does not include cellular or Ethernet connectivity; however, the USB data export protocol is compatible with custom middleware for integration into SCADA or cloud-based environmental dashboards via edge-device gateways.
What maintenance intervals are recommended for the sampling pump and flow sensors?
Pump diaphragms should be inspected every 6 months or after 2,000 operating hours; temperature and pressure sensors require annual verification against NIST-traceable references per JJG 956–2013 calibration procedures.
Are calibration certificates provided with the instrument?
Each unit ships with a factory calibration report covering flow rate (at 20, 50, and 100 L/min), temperature, and pressure channels, traceable to CNAS-accredited metrology labs. On-site recalibration services are available through authorized HUANKONG service centers.