Empowering Scientific Discovery

HUANKONG JHK-1000 Constant-Flow Ambient Air Sampler

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HUANKONG
Model JHK-1000
Type Dual-Channel Constant-Flow Gas Sampler
Flow Control PID-regulated Mass Flow Controller
Flow Accuracy ±2% of setpoint (typical, per HJ/T 375–2007)
Flow Range 10–1000 mL/min per channel
Power Supply Rechargeable Li-ion battery (≥12 h continuous operation)
Data Storage >1000 sample records per channel
Filtration Dual-stage particulate filter (≤2 µm cutoff)
Environmental Sensors Integrated temperature & barometric pressure sensor
Compliance Fully aligned with GB/T 18883–2022, HJ/T 375–2007, HJ 644–2013, HJ 583–2010, HJ 584–2010, HJ/T 400–2007, GB/T 17061–1997, GB 50325–2020, JJG 956–2013

Overview

The HUANKONG JHK-1000 Constant-Flow Ambient Air Sampler is an engineered solution for regulatory-grade atmospheric sampling in compliance with national and method-specific environmental monitoring standards. Designed around Couette-flow mass flow control architecture, it delivers stable, traceable volumetric sampling across variable backpressure conditions—critical when collecting analytes such as formaldehyde, ammonia, benzene, TVOCs, aldehydes, and respirable particulates from ambient air, indoor environments, or occupational workspaces. Its dual-channel configuration enables parallel sampling for inter-method validation or multi-analyte capture (e.g., simultaneous adsorption tube + filter membrane collection), supporting both integrated and time-resolved exposure assessment protocols required under GB/T 18883–2022 and GB 50325–2020.

Key Features

  • PID-controlled mass flow regulation ensures consistent volumetric delivery across dynamic resistance loads (e.g., activated carbon tubes, quartz filters, impingers), minimizing flow drift to ≤±2% of setpoint per HJ/T 375–2007 verification criteria.
  • High-efficiency brushless DC sampling pump provides extended service life (>10,000 h MTBF) and low acoustic emission (<45 dB[A]), suitable for unattended field deployment.
  • Integrated environmental compensation: real-time measurement of ambient temperature and barometric pressure enables automatic conversion of measured flow to standard temperature and pressure (STP: 273.15 K, 101.325 kPa) and cumulative standard-volume calculation per GB/T 17061–1997.
  • Dual-stage particulate filtration (≤2 µm cut-off) protects internal flow sensors and pump components from dust loading during long-duration industrial hygiene surveys.
  • Flexible sampling modes include instantaneous, timed, volume-triggered, and interval-based acquisition—supporting OSHA ID-135, NIOSH 2541, and EPA TO-17 workflows.
  • Onboard non-volatile memory retains >1000 sample logs per channel, including timestamp, setpoint, actual flow, STP volume, temperature, pressure, and battery status—fully traceable for GLP audit trails.
  • Rechargeable lithium-ion power system sustains ≥12 hours of continuous dual-channel operation at 200 mL/min; optional tripod mount enables height-adjustable sampling per ISO 8518 and EN 13205 field protocols.

Sample Compatibility & Compliance

The JHK-1000 interfaces seamlessly with standardized collection media: 37-mm and 47-mm filter cassettes (for PM2.5, metals, or endotoxin analysis), stainless steel or glass adsorption tubes (Tenax TA, Carbopack B, silica gel), impinger vessels (for formaldehyde or SO2), and Tedlar® gas sampling bags. It meets mechanical and metrological requirements defined in JJG 956–2013 (verification regulation for air samplers) and supports analytical methods referenced in HJ 644–2013 (VOCs by TD-GC/MS), HJ 583–2010 and HJ 584–2010 (benzene series), and HJ/T 400–2007 (in-vehicle VOCs). Its data structure and calibration traceability align with ISO/IEC 17025 documentation expectations for accredited laboratories.

Software & Data Management

Field-collected data are exportable via USB-C interface in CSV format, compatible with LIMS integration and statistical review platforms (e.g., R, Python pandas, or commercial QA/QC software). Optional Bluetooth thermal printer support enables on-site generation of compliant field log sheets with embedded instrument ID, operator tag, and calibrated flow certificate metadata. All stored parameters—including flow deviation history, battery discharge curve, and environmental compensation coefficients—are retained with millisecond-level timestamps, satisfying FDA 21 CFR Part 11 electronic record integrity requirements when paired with controlled access procedures.

Applications

  • Indoor air quality (IAQ) assessment per GB/T 18883–2022 and ISO 16000 series standards.
  • Workplace exposure monitoring for VOCs, aldehydes, and respirable dust in accordance with GBZ 159–2004 and ACGIH TLV® guidelines.
  • Pre- and post-remediation verification in building commissioning and renovation projects (GB 50325–2020).
  • Mobile source emissions characterization (e.g., parking garage, tunnel, or fleet depot sampling).
  • Educational laboratory instruction in environmental chemistry and occupational hygiene sampling methodology.
  • Research-grade ambient VOC speciation campaigns requiring synchronized multi-media capture (adsorbent + filter + impinger).

FAQ

Does the JHK-1000 comply with U.S. EPA or EU EN standards?
While designed primarily for Chinese national standards (HJ, GB, JJG), its flow stability, pressure/temperature compensation, and data logging architecture meet technical equivalency benchmarks for EPA Compendium Method IP-1A and EN 12341:2014 field sampling performance.
Can the instrument be calibrated externally using a primary standard?
Yes—each unit ships with a NIST-traceable calibration certificate; field recalibration is supported via gravimetric or bubble-meter reference methods per HJ/T 375–2007 Annex B.
Is firmware upgrade available remotely?
Firmware updates are distributed via secure download portal and applied through USB-C connection; version history and change logs are provided for audit readiness.
What maintenance intervals are recommended?
Pump brushes require no replacement (brushless design); particulate filters should be inspected before each deployment and replaced after 50 hours of high-dust operation or per visual clogging assessment.
How is data integrity ensured during power interruption?
The device implements non-volatile SRAM buffering: all active sampling parameters and accumulated volumes are preserved instantaneously upon voltage drop, resuming from last valid state upon restart without loss.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0