KRUESS P8000-PT Automatic Polarimeter with Integrated Peltier Temperature-Controlled Sample Cell
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | P8000-PT |
| Product Type | Automatic Polarimeter |
| Measurement Principle | Optical Rotation at 589 nm (Na D-line) |
| Temperature Control | Integrated Peltier-Heated/Cooled Sample Cell (PRG-100-EPT) |
| Measurement Range | ±90° / ±259 °Z / 0–99.9 g/100 mL |
| Resolution | 0.001°, 0.01 °Z, 0.1 g/100 mL |
| Accuracy | ±0.003°, ±0.01 °Z, ±0.5 g/100 mL |
| Repeatability | 0.002° |
| Measurement Time (±90°) | 1 s |
| Wavelength | 589 nm (LED source, optional alternate wavelengths available) |
| Cell Path Length | 220 mm |
| Temperature Range | 15.0–40.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Display | 5.7″ TFT LCD (320 × 240 px) |
| Interface | RS-232, USB, Ethernet |
| Data Storage | 999 measurements |
| Power | 90–250 V, 50/60 Hz |
| Dimensions | 64.5 × 20.0 × 36.0 cm |
| Weight | 28 kg |
Overview
The KRUESS P8000-PT is a high-performance automatic polarimeter engineered for precision optical rotation measurement under rigorously controlled thermal conditions. Unlike conventional polarimeters requiring external water baths or ambient-temperature operation, the P8000-PT integrates a proprietary Peltier-based temperature-controlled sample cell (PRG-100-EPT), enabling direct, real-time regulation of sample temperature at the measurement point—within the cell itself. This architecture eliminates thermal lag, spatial gradients, and operator-dependent setup variability associated with bath-based systems. The instrument operates at the sodium D-line wavelength (589 nm) using a stable, long-life LED light source with optical filtering, ensuring compliance with international standards including ISO 5725 (accuracy and precision), USP (Optical Rotation), and EU Pharmacopoeia 2.2.7. Its 1-second full-range measurement capability (±90°) makes it the fastest commercially available polarimeter in its class, optimized for high-throughput QC environments where speed and reproducibility are critical.
Key Features
- Integrated Peltier temperature control system embedded directly within the sample cell housing—no external chiller or water bath required.
- Real-time temperature monitoring at the sample location via built-in Pt100 sensor; displayed continuously on the 5.7″ touch-sensitive TFT screen.
- Automated detection of sample cell insertion and thermal stabilization status—ensures measurement only initiates when thermal equilibrium is confirmed.
- Ultra-fast acquisition: ±90° optical rotation measured in ≤1 second with 0.001° angular resolution and ±0.003° accuracy.
- Multi-parameter output: simultaneous calculation and display of optical rotation (°), International Sugar Scale (°Z), concentration (g/100 mL), and user-defined calibration units.
- Robust mechanical design with 220 mm standard cell path length; compatible with both temperature-controlled (PRG-100-EPT) and standard unheated cells.
- Menu-driven self-calibration routine compliant with GLP documentation requirements, supporting traceable verification without external reference standards.
Sample Compatibility & Compliance
The P8000-PT accommodates standard 220 mm polarimetric cells with diameters up to 28 mm, including quartz and high-transmission glass variants. Its Peltier-regulated cell (PRG-100-EPT) features a thermally insulated metal sleeve and integrated thermal mass optimization, delivering uniform axial and radial temperature distribution (±0.2 °C stability across the entire sample volume). This enables reliable measurement of thermally sensitive compounds—including chiral pharmaceutical intermediates, enzymatic reaction mixtures, and unstable sugar derivatives—without degradation or conformational drift. The system meets regulatory expectations for instrument qualification per FDA 21 CFR Part 11 (with audit trail enabled via optional software), supports IQ/OQ documentation packages, and conforms to ISO/IEC 17025 calibration traceability frameworks when used with NIST-traceable sucrose standards.
Software & Data Management
Onboard firmware provides full standalone operation via intuitive touch interface, storing up to 999 complete measurement records—including date/time stamp, temperature reading, raw angle, derived concentration, and operator ID. All data are exportable via RS-232, USB, or Ethernet to LIMS or ERP systems using ASCII or CSV protocols. Optional KRUESS PolarSoft™ v4.x software extends functionality with multi-user access control, electronic signature support, automated report generation (PDF/Excel), and trend analysis tools aligned with ICH Q5 and Q7 guidelines. Audit trails log all parameter changes, calibration events, and data exports—fully compliant with GMP/GLP data integrity requirements.
Applications
- Pharmaceutical manufacturing: Enantiomeric purity assessment of active pharmaceutical ingredients (APIs), real-time monitoring of asymmetric synthesis, and stability-indicating assays for chiral degradation products.
- Sugar & starch processing: Brix and polarization index determination in cane/beet juice, invert sugar hydrolysis kinetics, and quality release testing of crystalline sucrose and fructose syrups per ICUMSA methods.
- Food & beverage QC: Authenticity verification of honey (glucose/fructose ratio), detection of adulteration in fruit juices, and concentration control in flavor extracts and essential oils.
- Chemical R&D: Kinetic profiling of stereospecific reactions, configurational assignment of novel chiral ligands, and batch-to-batch consistency validation for specialty fine chemicals.
- Academic & regulatory labs: Reference method implementation for pharmacopoeial monographs (e.g., EP 2.2.7, JP 2.05), method transfer studies, and inter-laboratory proficiency testing.
FAQ
Does the P8000-PT require external cooling water or refrigeration units?
No—the integrated Peltier module provides both heating and cooling within the sample cell assembly, eliminating dependency on auxiliary chillers or recirculating baths.
Can the instrument operate without temperature control?
Yes. Standard non-thermostatted cells may be used interchangeably; temperature control is an optional mode activated only when the PRG-100-EPT cell is detected.
Is the 589 nm wavelength fixed, or can other lines be selected?
The base configuration uses a stabilized 589 nm LED; alternative wavelengths (e.g., 405 nm, 488 nm, 633 nm) are available as factory-installed options upon request.
How is temperature calibration verified?
The system includes internal reference diagnostics and supports external verification using certified NIST-traceable thermistors or calibrated digital probes placed inside the cell during qualification.
What regulatory documentation is supplied with the instrument?
Each unit ships with Factory Acceptance Test (FAT) report, EU Declaration of Conformity (CE), ISO 9001-certified calibration certificate, and optional GMP-compliant IQ/OQ protocol templates.