Leici SFK-506VC Karl Fischer Moisture Analyzer
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SFK-506VC |
| Pricing | ¥88,900 CNY |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 3.0 μg – 200 mg (Coulometric), 100 μg – 250.0 mg (Volumetric) |
| Resolution | 0.1 μg (Coulometric), 1 μg (Volumetric) |
| Accuracy | ±0.3% |
| Repeatability | ≤0.3% |
| Polarization Current Range | (1–200) μA |
| Titration Control Precision | 0.1 μg |
| Power Supply | 100–240 VAC, 47–63 Hz |
| Data Storage | 2000 records per method (volumetric & coulometric) |
Overview
The Leici SFK-506VC Karl Fischer Moisture Analyzer is a dual-mode benchtop instrument engineered for high-precision quantitative determination of water content in pharmaceuticals, chemicals, polymers, petrochemicals, and food-grade materials. It implements both volumetric and coulometric Karl Fischer titration principles—compliant with ISO 8533, ASTM E203, and USP —to address the full spectrum of moisture analysis requirements: from trace-level (sub-microgram) detection in hygroscopic solids and solvents to higher-range quantification in viscous or heterogeneous samples. The system integrates electrochemical endpoint detection via bipotentiometric (dual-platinum electrode) sensing, ensuring robust reproducibility across matrix types. Its modular architecture supports optional integration with a KF oven (Heated Sample Furnace) for thermally driven water release from bound or crystalline matrices, extending applicability to samples incompatible with direct solvent dissolution.
Key Features
- 7-inch high-resolution color TFT touchscreen interface with intuitive icon-driven navigation and real-time titration curve visualization
- Dual-method capability: simultaneous support for volumetric KF (with standardized titrant dosing) and coulometric KF (electrolytic iodine generation), each with independent calibration, method storage, and validation workflows
- Integrated solvent management module featuring leak-proof fluid handling, anti-siphon waste bottle design, automated reagent dispensing, titration cell rinsing, and closed-loop solvent exchange—minimizing operator exposure to toxic KF reagents (e.g., pyridine-free methanol-based solutions)
- Three-tier user permission structure (System Administrator / Lab Manager / Analyst) aligned with ALCOA+ data integrity principles; full GMP-compliant audit trail logging including user ID, timestamp, parameter changes, and result modifications
- Comprehensive data governance: 2000 method-specific records per mode (volumetric/coulometric), encrypted local storage, PDF report generation with digital signature support, and secure export via USB, Wi-Fi, or Ethernet
- Regulatory-ready software architecture supporting 21 CFR Part 11 compliance (electronic signatures, role-based access, immutable audit logs), GLP documentation standards, and seamless integration with LIMS via CSV/Excel export protocols
Sample Compatibility & Compliance
The SFK-506VC accommodates liquid, solid, paste, and gas-phase samples through multiple introduction pathways: direct syringe injection, automated sample changer (optional), and KF oven coupling (SFK-Oven accessory). Solids—including APIs, excipients, catalysts, and battery electrolyte salts—are heated up to 300 °C under inert gas purge to liberate occluded or lattice-bound water prior to coulometric detection. Liquids (e.g., acetonitrile, ethylene glycol, silicone oils) are analyzed via volumetric titration using certified KF reagents (e.g., Hydranal-Composite 5). All measurement units—μg, mg, %, ppm, μg/L, mg/L, and μg/mL—are selectable per test protocol and auto-converted during reporting. Device firmware and software comply with IEC 61010-1 (electrical safety), ISO/IEC 17025 clause 5.9 (data control), and EU Annex 11 (computerized system validation) requirements.
Software & Data Management
Leici KF Control Software (v3.2+) provides a validated desktop platform for instrument control, method development, and raw data review. It enforces electronic signature workflows per FDA 21 CFR Part 11 Subpart B, maintains time-stamped, tamper-evident audit trails for all critical actions, and supports periodic backup to network drives or cloud repositories (AWS S3 or Azure Blob configured via IT policy). Reports include metadata (sample ID, analyst, environmental conditions, reagent lot numbers), titration curves, equivalence point calculation algorithms (fixed potential, dynamic slope, or second-derivative peak detection), and uncertainty estimation per GUM guidelines. Data exports meet laboratory accreditation criteria: CSV for statistical analysis, PDF/A-1b for archival, and XML for LIMS ingestion.
Applications
- Pharmaceutical QC: Water content verification of lyophilized powders (≤100 μg H₂O), tablet coatings, and sterile injectables per EP 2.5.12
- Chemical manufacturing: Moisture monitoring in lithium hexafluorophosphate (LiPF₆) electrolytes, polyamide resins, and organometallic catalysts
- Petrochemical QA: Detection of residual water in transformer oils (ASTM D6304), jet fuels (ASTM D6304), and biodiesel blends (EN 14971)
- Food & agriculture: Quantification of free water in dried fruits, milk powders, and cereal grains per AOAC 955.01
- Materials science: Hydration state analysis of metal-organic frameworks (MOFs), zeolites, and battery cathode precursors
FAQ
Does the SFK-506VC support both volumetric and coulometric KF methods on a single platform?
Yes—the instrument automatically detects and configures the appropriate measurement mode based on installed reagent modules and selected method templates.
Is the KF oven (SFK-Oven) included as standard equipment?
No—the heated sample furnace is an optional accessory; it connects via dedicated pneumatic and electrical interfaces and is controlled synchronously through the main unit’s software.
How does the system ensure reagent safety during solvent handling?
The integrated solvent manager uses gravity-fed, pressure-balanced fluid paths with check valves and air-gap isolation to prevent backflow, overflow, or operator contact with KF reagents.
Can measurement data be exported directly to a corporate LIMS without third-party middleware?
Yes—CSV and XML export formats are natively supported; structured metadata fields align with ASTM E1467 and ISO/IEC 11179 standards for automated ingestion.
What validation documentation is provided for GMP environments?
Leici supplies a comprehensive IQ/OQ protocol package, including factory calibration certificates traceable to NIM (National Institute of Metrology, China), reagent blank validation reports, and software validation summary per GAMP 5.