Empowering Scientific Discovery

PMM9010/03P EMI Receiver

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Italy
Manufacturer Type Authorized Distributor
Origin Category Imported
Model PMM9010/03P
Pricing Upon Request

Overview

The PMM9010/03P EMI Receiver is a fully compliant, digitally architected radio frequency metrology instrument engineered for electromagnetic interference (EMI) measurement in accordance with CISPR 16-1-1:2019 and related EMC standards. Designed around a modern digital superheterodyne architecture with a synthesized local oscillator and parallel six-detector processing, it delivers high-fidelity amplitude detection across its base frequency range of 10 Hz to 300 MHz—covering the full spectrum required for conducted and radiated emissions testing per EN 55032, EN 55035, MIL-STD-461G (RS103), and FCC Part 15/18. Its modular hardware design enables seamless field-upgradability to extended bands (up to 3 GHz, 6 GHz, or 18 GHz) without system recalibration, supporting evolving regulatory requirements including automotive CISPR 25 and aerospace DO-160 Section 20. The receiver operates as both a standalone measurement platform and an integrated node within automated EMC test systems, satisfying GLP-compliant traceability and audit-ready data integrity requirements.

Key Features

  • Digital superheterodyne architecture with fully synthesized, temperature-compensated internal LO
  • Six parallel detectors: Peak (PK), Quasi-Peak (QP), Average (AV), RMS-AVG, CISPR-Average (CISPR-AV), and APD (Amplitude Probability Distribution) — all processed simultaneously in real time
  • Integrated signal generator and scalar network analyzer (SNA) functionality for cable loss verification, antenna factor application, and pre-scan calibration checks
  • Internal rechargeable Li-ion battery enabling continuous operation for >4 hours; supports AC/DC dual-mode power input
  • Embedded non-volatile memory storing user-defined limits, antenna factors, cable loss tables, probe calibration coefficients, and standard-specific test templates
  • Modular hardware design: Field-replaceable, factory-precalibrated functional modules (e.g., RF front-end, IF processor, detector board) ensure rapid service turnaround and metrological continuity
  • Firmware-upgradable architecture with secure over-the-air (OTA) capability to incorporate future revisions of CISPR, IEC, ISO, and MIL-STD standards

Sample Compatibility & Compliance

The PMM9010/03P is compatible with all standard EMC transducers—including biconical, log-periodic, and active rod antennas; LISNs (e.g., PMM 9170 series); current probes (e.g., PMM 9110); and near-field probes—via calibrated input interfaces adhering to IEC 61000-4-3 and IEC 61000-4-6. It satisfies full compliance with CISPR 16-1-1:2019 Class A specifications for bandwidths (200 Hz, 9 kHz, 120 kHz, 1 MHz), detector accuracy, and pulse response. Optional firmware modules support ØClick (click rate analysis per CISPR 16-2-3), RMS-AVG ratio evaluation (per IEC 61000-4-7), and statistical APD measurements (per CISPR 16-1-4). The device meets CE marking requirements under the EU EMC Directive 2014/30/EU and is suitable for use in accredited laboratories operating under ISO/IEC 17025:2017.

Software & Data Management

The receiver integrates with PMM’s EMITEST Suite v5.x software via USB 2.0 or Ethernet (TCP/IP), supporting remote control via SCPI commands and full compatibility with National Instruments LabVIEW™ and MATLAB® APIs. All measurement data—including raw spectra, time-domain traces, detector histograms, and limit line overlays—are stored in IEEE 1584-compliant .EMI binary format with embedded metadata (timestamp, operator ID, calibration certificate ID, transducer serial numbers). Audit trails record every parameter change, test execution, and firmware update, fulfilling FDA 21 CFR Part 11 electronic record/electronic signature (ERES) requirements when deployed in regulated medical or defense environments. Data export supports CSV, XML, and PDF report generation with customizable branding and signature fields.

Applications

  • Pre-compliance and full-compliance radiated/conducted emissions testing for consumer electronics, industrial equipment, and IoT devices
  • EMC troubleshooting and整改 (rework verification) in R&D labs and manufacturing QA lines
  • Military/aerospace EMI validation per MIL-STD-461G RS103 (radiated susceptibility) and CS114 (conducted susceptibility)
  • Automotive EMC testing per CISPR 25 Ed.5 (Class 3/4/5), ISO 11452-2, and SAE J1113-41
  • Telecom infrastructure compliance (ETSI EN 301 489-1, EN 300 386)
  • Calibration laboratory reference-grade measurements supporting ISO/IEC 17025 accreditation

FAQ

Is the PMM9010/03P compliant with CISPR 16-1-1:2019 Class A requirements?
Yes — it meets all mandatory performance criteria for bandwidth accuracy, detector linearity, pulse response, and noise floor specified in CISPR 16-1-1:2019 Annex B.
Can the instrument be upgraded to operate beyond 300 MHz?
Yes — optional hardware modules extend coverage to 3 GHz, 6 GHz, or 18 GHz, each validated against CISPR 16-1-1 and ANSI C63.4-2014 requirements.
Does it support automated test sequencing per EN 55032?
Yes — built-in test wizards enable fully automated sweeps, detector switching, margin analysis, and pass/fail reporting per EN 55032 Table 1 and Table 2 limits.
What calibration documentation is provided?
Each unit ships with a NIST-traceable calibration certificate (ISO/IEC 17025 accredited), including uncertainty budgets for all frequency bands and detector modes.
Is remote operation supported for integration into automated test cells?
Yes — SCPI command set, Ethernet-based TCP/IP control, and native LabVIEW drivers enable seamless integration with industrial PLCs and test management systems.