Thermo Fisher Trace GC 2000 Used Gas Chromatograph
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Trace GC 2000 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Dimensions (H×W×D) | 444 × 648 × 558 mm |
| Column Oven Temperature Range | Ambient + x°C to 450°C (optional LN₂ cooling to –99°C) |
| Ramp Rate | 0.1–120 °C/min (7-stage, 8-step programming) |
| Cool-down Time | 250 s (450 °C → 50 °C) |
| Heating Time | 390 s (50 °C → 450 °C) |
| Power Supply | 220/230 V ±10%, 50/60 Hz, 16 A |
| Max Power Consumption | 2700 W |
| Avg Power Consumption | 650 W |
| Sample Introduction | Split/Splitless (S/SL), Programmable Temperature Vaporizer (PTV), Cold On-Column (COC), PTV, HeadSpace, Purge & Trap, Thermal Desorption |
| Detectors Supported | FID, TCD, ECD, NPD, FPD, PID, PDD, Full Line of Thermo Scientific MS Detectors |
| Autosamplers | AS2000, TriPlus AS |
| Electronic Pressure & Flow Control (EPC) | Yes |
| Column Evaluation & Leak Detection | Automated self-test and column performance assessment |
| Detector Simultaneity | Up to 3 detectors operational concurrently with detector switching/sequencing capability |
Overview
The Thermo Fisher Trace GC 2000 is a high-performance, modular gas chromatograph engineered for precision, reproducibility, and long-term operational stability in regulated and research-intensive laboratory environments. Based on robust capillary GC architecture, it employs advanced electronic pressure and flow control (EPC) to deliver sub-milliliter-per-minute accuracy across carrier gases (He, H2, N2) and complex multi-gas configurations. Its oven design features rapid thermal mass management—achieving 450 °C → 50 °C cooling in under 250 seconds and 50 °C → 450 °C ramping in 390 seconds—enabling high-throughput method development and routine analysis without thermal lag artifacts. The instrument supports full compliance with ASTM D3606, D5186, D6729, ISO 10301, USP , and EPA Methods 502.2, 608, 8021B, and 8260 via validated detector configurations and audit-ready data acquisition protocols.
Key Features
- Modular platform supporting up to two independent inlets (e.g., S/SL + PTV) and three detectors simultaneously, with hardware-level detector sequencing logic
- Seven-segment, eight-step programmable temperature ramping with resolution of 0.1 °C/min and absolute oven temperature stability of ±0.01 °C over 24 h
- Full digital EPC system with real-time flow calibration traceability to NIST-traceable standards; pressure control accuracy ±0.01 psi
- Automated column evaluation routine—including retention time indexing, peak asymmetry analysis, and backflush validation—integrated into startup diagnostics
- Self-diagnostic leak detection protocol utilizing baseline noise profiling, pressure decay monitoring, and carrier gas purity verification algorithms
- Expandable inlet options: cold on-column (COC), programmed temperature vaporization (PTV), headspace, purge-and-trap, and thermal desorption interfaces—all factory-aligned and mechanically registered
- Optional liquid nitrogen cooling enables cryogenic oven operation down to –99 °C for volatile compound retention and high-resolution separation of light hydrocarbons
Sample Compatibility & Compliance
The Trace GC 2000 accommodates diverse sample matrices including environmental water extracts, petrochemical distillates, pharmaceutical residual solvents, food flavor volatiles, and forensic toxicology specimens. Its inlet and detector flexibility ensures compatibility with ISO 17025-accredited workflows, FDA 21 CFR Part 11-compliant data handling (when paired with appropriate Thermo Scientific Chromeleon CDS software versions), and GLP/GMP audit requirements. All supported detectors—including FID (ASTM D1945), ECD (EPA 8081B), NPD (USP nitro-compound testing), and TCD (ISO 6974)—are calibrated per manufacturer-recommended procedures using certified reference materials (CRMs) traceable to NIST SRMs. Instrument qualification documentation (IQ/OQ/PQ templates) and preventive maintenance logs are provided with each refurbished unit.
Software & Data Management
Controlled via Thermo Scientific Chromeleon Chromatography Data System (CDS) v7.3 or later, the system supports full 21 CFR Part 11 compliance when deployed with networked user authentication, electronic signatures, and immutable audit trails. Raw data files (.RAW) are stored in vendor-neutral formats compatible with third-party processing tools (e.g., OpenChrom, ACD/Labs). Method transfer functionality allows seamless migration from legacy GC platforms (e.g., Focus GC, Ultra GC) while preserving retention indexing and integration parameters. Batch processing, automated calibration curve generation, and customizable report templates meet ISO/IEC 17025 reporting requirements. Remote monitoring via secure HTTPS interface enables real-time status checks and alarm notifications without local workstation dependency.
Applications
- Environmental analysis: VOCs in drinking water (EPA 524.4), pesticides in soil (EPA 8081B), PCB congeners in sediment (EPA 8082)
- Petrochemical testing: Simulated distillation (SIMDIS) per ASTM D2887, PIONA analysis per ASTM D5134, natural gas composition (NGA) per GPA 2145
- Pharmaceutical QC: Residual solvent quantification per ICH Q3C guidelines using headspace-GC/FID
- Food & flavor: Fatty acid methyl ester (FAME) profiling, terpene fingerprinting, off-flavor compound identification
- Forensic toxicology: Ethanol/blood alcohol confirmation, benzodiazepine screening via GC-MS coupling
- Materials science: Outgassing analysis of polymers and composites using thermal desorption-GC/FID
FAQ
Is this unit fully refurbished and tested prior to shipment?
Yes. Each Trace GC 2000 undergoes comprehensive functional validation at SpectraLab Scientific’s ISO 9001-certified refurbishment facility, including oven thermal profiling, EPC linearity verification, detector sensitivity benchmarking (e.g., FID: ≤1.5 pg C/s), and system leak testing to <1×10−8 atm·mL/s.
What documentation accompanies the instrument?
A complete set includes factory service records, calibration certificates (traceable to NIST standards), IQ/OQ protocol templates, safety compliance statements (CE, UL), and a signed warranty certificate covering parts and labor for six months.
Can this GC be integrated into an existing LIMS environment?
Yes. Chromeleon CDS supports ASTM E1578-compliant LIMS connectivity via ODBC, HL7, or direct API integration. Custom field mapping and result auto-push modules are available upon request.
Are consumables and spare parts available post-purchase?
SpectraLab maintains global inventory of GC columns (Rtx, DB, HP series), septa, liners, ferrules, detector components, and OEM-certified EPC modules—with same-day shipping from EU, US, and APAC distribution hubs.