Empowering Scientific Discovery

Titan SCR-30 30-Gallon (114 L) Flammable Liquid Safety Cabinet

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model SCR-30
Capacity 30 US gallons (114 L)
Compliance Meets ANSI/SFIA Z129.1 and OSHA 1910.106 requirements for flammable liquid storage

Overview

The Titan SCR-30 is a UL-listed (or UL-recognized per ANSI/SFIA Z129.1) 30-gallon (114 L) flammable liquid safety cabinet engineered for secure, code-compliant storage of Class I, II, and IIIA flammable and combustible liquids in laboratory, pharmaceutical, chemical processing, and industrial R&D environments. Designed in accordance with OSHA 1910.106 and NFPA 30 standards, the cabinet employs double-walled 18-gauge steel construction with a 1.5-inch air gap for thermal insulation and fire resistance. Its self-closing, three-point latching door—equipped with a 2-inch adjustable hinge and fusible link (melting point: 70 °C / 158 °F)—automatically seals during fire exposure to inhibit flame propagation and vapor release. The unit includes leak-proof, 2-inch-deep galvanized steel spill containment sump, grounding hardware (copper grounding lug and 10 AWG wire), and dual vent ports (optional ducting for active fume extraction).

Key Features

  • Robust structural integrity: 18-gauge double-wall steel body with 1.5-inch insulating air space, tested to withstand ≥10 minutes of 1,093 °C (2,000 °F) fire exposure per ASTM E119 protocols
  • Self-closing, self-latching door mechanism with positive-locking 3-point latch and automatic closure via fusible link at 70 °C
  • Integrated spill containment sump rated for full cabinet capacity (114 L), sloped floor design for centralized liquid recovery
  • Factory-installed grounding system compliant with NEC Article 250 and NFPA 70 for static dissipation
  • Dual 2-inch NPT threaded vent openings (front and rear), configurable for passive ventilation or connection to facility exhaust ductwork
  • High-visibility, bilingual (English/Spanish) warning labels pre-applied per OSHA 1910.1200 and ANSI Z535.4 standards
  • Adjustable leveling feet and recessed door handle for ergonomic access and stable placement on lab flooring

Sample Compatibility & Compliance

The SCR-30 is certified for storage of common laboratory solvents including acetone, ethanol, methanol, toluene, xylene, ethyl acetate, and petroleum ether. It is not intended for pressurized containers, reactive metals (e.g., sodium, potassium), or oxidizers (e.g., nitric acid, hydrogen peroxide >8%). The cabinet meets or exceeds requirements of ANSI/SFIA Z129.1–2022, OSHA 1910.106(a)(1), NFPA 30 Chapter 9, and local fire codes governing indoor flammable liquid storage. Documentation includes factory test reports for door closure timing (<5 seconds), sump integrity (no leakage under static 114 L water load), and label legibility (UV-stabilized vinyl, 10-year outdoor durability rating).

Software & Data Management

As a passive mechanical safety device, the SCR-30 does not incorporate embedded electronics, firmware, or data logging capabilities. All operational parameters—including door actuation force, sump retention volume, and grounding continuity—are verified during factory quality assurance using calibrated torque meters, hydrostatic pressure testers, and milliohm meters. Inspection and maintenance records are maintained per institutional EH&S protocols; optional QR-coded asset tags support integration into CMMS platforms (e.g., IBM Maximo, UpKeep) for scheduled audits and regulatory traceability.

Applications

  • Secure daily storage of working volumes of flammable reagents in analytical chemistry, QC/QA, and synthetic laboratories
  • Intermediate staging of solvents near HPLC, GC, and sample preparation workstations while maintaining separation from ignition sources
  • Compliant storage in GMP-regulated environments where segregation of Class I liquids from general lab areas is mandated by FDA 21 CFR Part 211 and EU Annex 1
  • Support for ISO/IEC 17025-accredited testing labs requiring documented chain-of-custody for hazardous material handling
  • Integration into university teaching labs where NFPA 45-compliant solvent management is required for undergraduate instruction

FAQ

Does the SCR-30 require external ventilation to operate safely?

No—ventilation is optional. The cabinet is certified for unvented use when installed per NFPA 30 Section 9.5.2. Ducting is recommended only where facility-wide vapor concentration monitoring or process-specific exhaust requirements apply.
Can this cabinet be used for storing corrosive liquids such as concentrated acids?

No. The SCR-30 is specifically designed and tested for flammable organic liquids. Corrosives require polyethylene- or stainless-steel-lined cabinets meeting ANSI Z129.1 Corrosives classification criteria.
Is third-party certification documentation available for audit purposes?

Yes. Titan provides a Certificate of Conformance, ANSI/SFIA Z129.1 test summary report, and OSHA/NFPA alignment statement upon request—fully traceable to batch number and manufacturing date.
What is the recommended inspection frequency per regulatory guidance?

OSHA 1910.106(f)(5) and NFPA 30 Section 9.5.3 mandate visual inspection before each shift; formal documented inspection (including grounding continuity and door closure verification) must occur at least quarterly.