Waters Micromass LCT Premier Time-of-Flight Mass Spectrometer (Refurbished)
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | LCT Premier |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Ionization Sources | ESI, LockSpray, optional APCI/APPI/ESCI/NanoLockSpray/MUX |
| Mass Analyzer | Orthogonal Acceleration TOF (oa-TOF) |
| Detector | Dual Microchannel Plate (MCP) Assembly |
| Data Acquisition | 4.0 GHz Time-to-Digital Converter (TDC) with Onboard Histogramming |
| Control & Acquisition Software | MassLynx NT 4.x |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Condition | Factory-refurbished, fully tested and validated |
Overview
The Waters Micromass LCT Premier is a high-performance, orthogonal acceleration time-of-flight (oa-TOF) mass spectrometer engineered for high mass accuracy, wide dynamic range, and robust quantitative and qualitative analysis in research and regulated laboratory environments. Designed around the fundamental principles of time-of-flight mass spectrometry—where ions are accelerated by a fixed voltage pulse and separated based on their time-of-flight to a detector—the LCT Premier delivers sub-ppm mass accuracy and isotopic fidelity across a broad m/z range (up to 20,000 Da). Its core architecture integrates a Z-Spray electrospray ionization (ESI) source with integrated LockSpray™ reference calibration, enabling real-time internal mass correction during acquisition. The instrument employs an ion-guiding optics system optimized for efficient transmission from atmospheric pressure sources into the high-vacuum oa-TOF region, minimizing signal loss and enhancing sensitivity reproducibility.
Key Features
- Orthogonal acceleration TOF mass analyzer with reflectron mode for enhanced resolution and mass accuracy
- Z-Spray ESI source with integrated LockSpray™ interface for continuous, real-time mass calibration
- Modular ion source compatibility: supports optional APCI, APPI, ESCI, NanoLockSpray, and MUX multiplexed ion introduction
- Dual microchannel plate (MCP) detector assembly for high gain, low noise, and extended linear dynamic range
- 4.0 GHz time-to-digital converter (TDC) with onboard histogramming for high-speed, high-fidelity transient data capture
- Embedded industrial PC running MassLynx NT 4.x software for instrument control, data acquisition, and basic processing
- Refurbished and fully validated per Waters-recommended protocols; includes full functional testing of vacuum integrity, detector response, ion transmission efficiency, and mass calibration stability
Sample Compatibility & Compliance
The LCT Premier accommodates a wide range of sample types—from small molecules and peptides to intact proteins and synthetic polymers—when coupled with liquid chromatography (e.g., Waters Alliance or ACQUITY UPLC systems) or direct infusion. Its ESI and optional APCI/APPI sources support polar, thermally labile, and moderately volatile analytes. The system meets essential requirements for GLP and GMP-aligned workflows when operated with audit-trail-enabled MassLynx configurations compliant with FDA 21 CFR Part 11 (with appropriate user access controls and electronic signature implementation). While not certified as a medical device, its performance characteristics align with ASTM E2603-20 (Standard Guide for Mass Spectrometry Data Acquisition and Processing) and ISO/IEC 17025:2017 method validation expectations for mass spectrometric identification and quantification.
Software & Data Management
Instrument operation and data acquisition are managed through MassLynx NT 4.x—a Windows-based platform supporting method development, real-time spectral monitoring, centroid and profile mode acquisition, and post-run processing including peak detection, deconvolution, and elemental composition prediction. Raw data files (.raw) are stored in proprietary format but exportable to open standards (e.g., mzXML, mzML) via compatible converters. All refurbished units ship with licensed MassLynx software, validated driver packages, and documented installation verification reports. Data integrity is maintained through configurable acquisition logging, session-level metadata tagging, and optional integration with Laboratory Information Management Systems (LIMS) via ODBC or API extensions.
Applications
The LCT Premier serves critical roles in pharmaceutical R&D (metabolite identification, impurity profiling, peptide mapping), academic proteomics (top-down and bottom-up workflows), environmental analysis (persistent organic pollutants, pesticide residues), and polymer characterization (molar mass distribution, end-group analysis). Its high mass accuracy enables confident differentiation of isobaric species (e.g., leucine/isoleucine, phosphorylation vs. sulfation), while its fast acquisition rate supports coupling with ultrafast LC separations. In regulatory contexts, it supports ICH Q5A/Q5B-compliant characterization of biologics and USP method suitability assessments when paired with appropriate system suitability tests.
FAQ
Is this instrument suitable for regulated GxP environments?
Yes—when configured with MassLynx NT 4.x under validated conditions, including electronic signatures, audit trails, and role-based access controls, the LCT Premier supports compliance with FDA 21 CFR Part 11 and ISO/IEC 17025 requirements.
What level of technical support is included post-purchase?
All units include 6 months of hardware warranty and remote diagnostic support. On-site service contracts and application-specific training can be arranged separately.
Can the LCT Premier be interfaced with modern UHPLC systems?
Yes—it is fully compatible with Waters ACQUITY UPLC and other vendor LC platforms via standard analog/digital I/O and trigger synchronization protocols.
Does the refurbishment include replacement of consumables and critical wear parts?
Yes—refurbishment includes replacement of ion optics components, MCP detectors, vacuum pump oils/filters, and recalibration of all high-voltage supplies and timing circuits.
Are original manufacturer documentation and calibration certificates provided?
Yes—each unit ships with a full refurbishment dossier, including vacuum test logs, mass calibration reports, sensitivity verification data, and a traceable certificate of conformance.