Empowering Scientific Discovery

Zhongyi Yusheng HTB-3420B Adsorption Tube Aging Instrument

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Zhongyi Yusheng
Origin Beijing, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model HTB-3420B
Adsorption Tubes Capacity 24
Heating Stages 5-zone programmable ramping
Cooling Method Forced-air rapid cooling
Gas Control Electronic mass flow controllers (MFCs)
User Interface 7-inch capacitive touch screen
Exhaust Management Electronically actuated exhaust valve with centralized outlet
Tubing Material Stainless steel
Pre-filtering Integrated particulate and hydrocarbon filter at gas inlet
Tube Connection Quick-release fittings with low-wear sealing design
Independent Channel Operation Per-tube gas flow isolation and activation control

Overview

The Zhongyi Yusheng HTB-3420B Adsorption Tube Aging Instrument is a precision-engineered thermal conditioning system designed for the pre-analytical preparation of sorbent-packed adsorption tubes used in thermal desorption–gas chromatography (TD–GC) workflows. It operates on the principle of controlled, multi-stage thermal purging—where inert carrier gas flows through individual tubes while subjecting them to precisely programmed temperature profiles—to remove residual volatiles, moisture, and contaminants from sorbent beds prior to sampling. This process ensures baseline stability, minimizes carryover, and maximizes tube reusability—critical requirements for compliant environmental air monitoring (e.g., EPA TO-17), indoor air quality (IAQ) assessment, and occupational hygiene testing. The HTB-3420B is not a standalone analytical instrument but an essential front-end conditioning module that directly impacts method robustness, detection limit reproducibility, and long-term GC column integrity.

Key Features

  • 24-position parallel aging capacity: Enables high-throughput conditioning of standard 6 mm OD × 89 mm L stainless steel or glass adsorption tubes, supporting batch consistency across large-scale monitoring programs.
  • Five-zone independent thermal programming: Each heating zone supports user-defined ramp rates, hold times, and final temperatures (up to 400 °C), allowing optimization for diverse sorbent chemistries—including Tenax TA, Carbopack™ series, graphitized carbon blacks, and mixed-bed configurations.
  • Forced-air rapid cooldown system: Integrated high-CFM centrifugal blower and thermally isolated chamber architecture reduce average tube cooldown time from 400 °C to <50 °C in under 8 minutes—significantly improving turnaround versus passive cooling methods.
  • Electronic mass flow control (MFC): Dual-range MFCs (0–100 mL/min and 0–500 mL/min) deliver ±1% full-scale accuracy per channel, enabling precise carrier gas dosing during both purge and bake-out phases.
  • Per-tube gas isolation architecture: Solenoid-valve–controlled individual gas paths allow selective activation of any subset of tubes without cross-contamination or pressure imbalance—reducing total helium or nitrogen consumption by up to 70% compared to fixed-flow manifold systems.
  • Stainless steel gas pathway with integrated filtration: All wetted parts are electropolished 316L SS; a dual-stage inlet filter (0.01 µm particulate + activated charcoal) protects downstream components from compressor oil, moisture, and ambient hydrocarbons.
  • Intelligent exhaust management: A motorized three-way exhaust valve automatically seals the outlet during heating cycles and opens only during active purge/cool-down—preventing back-diffusion of ambient air or lab fumes into conditioned tubes.
  • 7-inch industrial-grade touch interface: Provides real-time visualization of all 24 tube statuses (temperature, flow, elapsed time), event logging, and password-protected method storage compliant with GLP audit trail requirements.

Sample Compatibility & Compliance

The HTB-3420B accommodates standard 1/4″–28 UNF threaded adsorption tubes (e.g., SKC, Markes, Gerstel formats) and accepts custom-length variants up to 110 mm. Its gas-tight quick-connect fittings eliminate O-ring twisting and extend seal life beyond 5,000 cycles. The system meets mechanical safety requirements per GB/T 20932–2007 (Chinese national standard for thermal desorption equipment) and supports alignment with ISO 16000-6:2011 (indoor air—determination of volatile organic compounds), ASTM D6196–22 (selection of sorbents), and EPA Method TO-17 Annex A (tube conditioning specifications). When operated with validated SOPs, it contributes to data integrity frameworks aligned with FDA 21 CFR Part 11 (electronic records/signatures) via its timestamped operation logs and user-access controls.

Software & Data Management

The embedded firmware supports method export/import via USB flash drive in CSV format, including full thermal and flow profiles for each tube position. Audit-ready event logs record start/stop timestamps, operator ID, deviations (e.g., temperature overshoot >±2 °C), and MFC calibration status—retained for ≥12 months onboard. Optional Ethernet connectivity enables remote monitoring and integration into LIMS via Modbus TCP or HTTP API endpoints. All stored methods are digitally signed to prevent unauthorized modification, satisfying traceability requirements under ISO/IEC 17025:2017 Clause 7.7.

Applications

  • Pre-conditioning of sorbent tubes for EPA-compliant ambient air toxics monitoring (e.g., benzene, formaldehyde, PAHs)
  • Reconditioning of reused tubes in occupational exposure assessments (NIOSH 5515, OSHA PV2121)
  • Method development for emerging VOCs using novel sorbent combinations
  • QC verification of tube lot-to-lot performance prior to field deployment
  • Supporting accredited laboratories pursuing CNAS or UKAS accreditation under ISO/IEC 17025

FAQ

Can the HTB-3420B age tubes containing moisture-sensitive sorbents such as silica gel or molecular sieves?
Yes—the five-stage heating profile allows gentle initial drying steps (e.g., 30 °C/30 min under dry nitrogen) before ramping to higher temperatures, minimizing sorbent degradation.
Is external gas supply regulation required?
No—the built-in MFCs accept inlet pressures from 0.2–0.6 MPa and regulate downstream flow autonomously; only a clean, oil-free source (e.g., zero-air generator or Grade 5 N₂) is needed.
How is calibration verified?
Each unit ships with NIST-traceable temperature and flow calibration certificates; annual verification uses external PT100 probes and bubble meters per ISO/IEC 17025 Clause 6.4.
Does the system support unattended overnight operation?
Yes—full-cycle scheduling, auto-shutdown upon completion, and overtemperature cut-off (450 °C hardware limit) ensure safe extended runs.
Can aging parameters be locked per tube position for multi-sorbent batches?
Yes—individual position configuration allows simultaneous aging of Tenax TA (320 °C), Carbopack B (300 °C), and Carboxen 1000 (280 °C) within one run.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0