Protein Purifier
Filter
Showing 1–30 of 38 results
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AGS-PHG05W06T-ET-K75E2-BE-Q3A |
| Pricing | Upon Request |
| Brand | AICHUN |
|---|---|
| Origin | Zhejiang, China |
| Model Variants | PPS-10HD, PPS-100HD, PPS-PilotHD |
| Pump Flow Ranges | 0.001–10 mL/min (PPS-10HD), 0.01–100 mL/min (PPS-100HD), 1–400 mL/min (PPS-PilotHD) |
| Max Pressure | 20 MPa (PPS-10HD), 10 MPa (PPS-100HD), 2 MPa (PPS-PilotHD) |
| UV Detection | 200–400 nm (standard), up to 800 nm (optional) |
| Conductivity Range | 0.00–1000.00 mS/cm |
| Gradient Accuracy | ±0.6% to ±2% (model-dependent) |
| System Dimensions (W×H×D) | 482 × 661 × 432 mm |
| Weight | ≤65 kg (fully configured) |
| Power | 100–240 VAC, 50/60 Hz |
| Compliance | Audit Trail-enabled PPSN Software (21 CFR Part 11 ready) |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | AGS-HAB04W08T-ET-K75E2-E-Q3A |
| Pricing | Upon Request |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | AGS-HZG05W12T-ET-K75E2-E-Q3A |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA pcc |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Detection Capabilities | UV Absorbance (280 nm, 254 nm), Conductivity, pH, Temperature, Pressure |
| Column Positions | 3 or 4 |
| Post-Loading Wash (PLW) Functionality | Yes |
| Regulatory Compliance Support | FDA 21 CFR Part 11, EU Annex 11, GLP/GMP-ready software architecture |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 28-9062-61 |
| Configuration | Pre-sterilized, disposable flow path system |
| Flow Rate Range | 50 mL/min to 510 L/hr |
| Column Diameter Compatibility | 70 mm – 450 mm |
| Regulatory Compliance | USP Class VI biocompatible materials |
| Manufacturing Environment | ISO 8 cleanroom packaging |
| Documentation | Full traceability, batch-specific validation dossiers, GMP-aligned support files |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Discover |
| Flow Rate Options | 10 mL/min (0–3650 psi) or 100 mL/min (0–1450 psi) |
| Buffer Blending | On-line gradient mixing with auto-buffer preparation valve system (2× flow boost: up to 20 mL/min for F10, 200 mL/min for F100) |
| UV Detection | Optional single-wavelength detector (255 nm / 280 nm) or full-spectrum diode array detector (190–800 nm, 4-channel simultaneous acquisition) |
| Software | ChromLab™ with integrated touchscreen interface |
| Sample Handling | Integrated autosampler valve |
| Fraction Collection | Optional BioFrac fraction collector |
| Modularity | Fully configurable with selectable valves (injection, column switching, effluent diversion), mixing chambers, and rack-mounted expansion modules |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Quest 10 |
| Flow Rate | 0–10 mL/min |
| Maximum Pressure | 3650 psi |
| Buffer Blending | Integrated Auto-Buffering Valve System (up to 20 mL/min effective flow) |
| UV Detection Options | Single-wavelength (255 nm / 280 nm) or Full-spectrum (190–800 nm, 4-channel simultaneous detection) |
| Software | ChromLab™ with touchscreen interface |
| Automation Modules | Optional sample/injection valves, column switching valves, fraction collection (BioFrac™), and outlet valves |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Scout |
| Flow Rate Options | 10 mL/min (max. 3650 psi) or 100 mL/min (max. 1450 psi) |
| Buffer Blending | On-line gradient mixing with auto-buffer preparation valve system (2× flow boost: up to 20 mL/min for F10, 200 mL/min for F100) |
| UV Detection | Optional single-wavelength detector (255 nm / 280 nm) or full-spectrum diode array detector (190–800 nm, 4-channel simultaneous acquisition) |
| Software | ChromLab™ with integrated touchscreen interface |
| Sample Handling | Integrated autosampler valve |
| Fraction Collection | Optional BioFrac™ square-format fraction collector |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 28-9308-42 |
| Application | Preparative Chromatography for Protein Purification |
| Flow Rate Range | Up to 25 mL/min |
| Max System Pressure | 20 MPa (200 bar) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| pH Measurement Range | 0–14, Accuracy ±0.1 pH (pH 2–12) |
| Temperature Monitoring Range | 0–99 °C, Accuracy ±1.5 °C (4–45 °C) |
| Fraction Collection Volume | 0.1–50 mL |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95%, non-condensing |
| Power Consumption | 1100 W |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTA avant |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Detection Range | UV 190–700 nm |
| System Pressure Rating | Up to 20 MPa |
| Flow Rate Range | 0.001–20 mL/min (AKTA avant 25) |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| UV Absorbance Range | –6 to +6 AU |
| pH Measurement Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12) |
| Temperature Control Range | 4–35 °C |
| Column Pressure Differential Monitoring | Dual integrated pressure sensors (pre- and post-column) |
| Buffer Preparation | Integrated BufferPro with quaternary valve, 26 preconfigured buffer recipes, real-time composition display |
| Software Platform | UNICORN 6 with FDA 21 CFR Part 11 compliance, audit trail, electronic signatures, role-based access control |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA avant |
| Flow Rate Options | 25 mL/min (AKTA avant 25) or 150 mL/min (AKTA avant 150) |
| Pressure Rating | Up to 20 MPa (200 bar) |
| Software | UNICORN 7.x or later |
| Column Tracking | RFID-enabled column recognition |
| Fraction Collector | Integrated Peltier-cooled (4–15 °C) |
| Buffer Preparation | BufferPro™ automated in-line mixing |
| Compliance | Supports 21 CFR Part 11-compliant configurations with audit trail, electronic signatures, and user access control |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA go Protein Purification System |
| Flow Rate | 0.01–25 mL/min |
| Max Operating Pressure | 5 MPa |
| UV Wavelength | 280 nm |
| Conductivity Range | 0.01–999.99 mS/cm |
| pH Range (optional) | 0–14 |
| Path Length (flow cell) | 2 mm (optional 5 mm) |
| Dimensions (W×D×H) | 335 × 464 × 482 mm |
| Weight | 27 kg |
| Power Consumption (typical) | 100 W |
| Safety Certifications | 2006/42/EC (MD), 2004/108/EC (EMC), 1999/5/EC (R&TTE) |
| IP Rating | IP21 |
| Tubing ID | 0.5 mm |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pcc |
| Application | Periodic Counter-Current Chromatography (PCC) for Protein Purification |
| Software | UNICORN™ Control Software |
| Configuration Options | 3-Column (3C) or 4-Column (4C) Setup |
| Regulatory Support | Change Control Notification (CCN) Service |
| Service Offering | OptiRun™ Lifecycle Support Program |
| Compliance Context | Designed for GMP-aligned process development and scale-up per ICH Q5, Q8, and Q9 principles |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pilot 600S |
| Application Scope | Non-GMP Process Development & Scale-up |
| Column ID Range | 26–200 mm |
| Flow Rate Range | 0.01–600 mL/min |
| Max Pressure | 20 MPa (200 bar) |
| System Architecture | Modular Benchtop Platform |
| Software Platform | UNICORN 7.x or later |
| Regulatory Support | Audit Trail, Electronic Signatures, User Access Levels (GMP-compliant configuration available in ÄKTA pilot 600R variant) |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | 29-0182-24 |
| Purification Principle | Affinity Chromatography (AC) |
| Detector Type | Xenon Lamp UV-Vis Detector |
| Absorbance Range | ±6 AU |
| Weight | 48 kg |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pure™ 150T |
| Maximum Flow Rate | 150 mL/min |
| UV Detection Wavelengths | Fixed at 260 nm and 280 nm |
| Software Platform | UNICORN 7 |
| Column Switching Capacity | Up to 10 columns via optional column selection valve |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA pure™ T Chromatography System |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Detectors | Dual-wavelength UV monitor (260 & 280 nm), Conductivity monitor, pH monitor |
| Flow Rate Range | ÄKTA pure™ 25T: 0.001–25 mL/min (up to 50 mL/min in column packing mode) |
| ÄKTA pure™ 150T | 0.01–150 mL/min (up to 300 mL/min in column packing mode) |
| Flow Accuracy | ÄKTA pure™ 25T: ±1.2% accuracy, RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| ÄKTA pure™ 150T | ±1.5% accuracy, RSD <0.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP) |
| Pressure Range | ÄKTA pure™ 25T: 0–20 MPa |
| ÄKTA pure™ 150T | 0–5 MPa |
| Conductivity Range | 0.01–999.99 mS/cm |
| pH Measurement | 0–14 pH units, ±0.1 pH accuracy (pH 2–12) |
| Solvent Compatibility | Compatible with ≥1 mol/L NaOH and ≥2 mol/L NaCl for >3 hours of in-place cleaning per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA ready XL |
| Flow Rate Range | 45–3500 L/h |
| Compatible Column ID | up to 1200 mm |
| Primary Application | GMP-compliant large-scale bioprocess purification |
| Software Platform | UNICORN 7+ with OPC UA connectivity |
| Regulatory Support | FDA 21 CFR Part 11 compliant audit trail, GMP documentation package available |
| Sensor Type | Single-use, calibrated-in-place (CIP) pressure, UV, conductivity, and temperature sensors |
| Footprint | Compact industrial design optimized for multi-product facility integration |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA ready™ 450 |
| System Type | Single-Use Preparative Chromatography Platform |
| Flow Rate Range | 0.01–45 mL/min |
| Hold-Up Volume | < 1.2 mL (system dead volume) |
| Pressure Limit | Up to 20 bar |
| Compliance | Designed for GMP-compliant small-scale bioprocessing |
| Sensor Integration | Integrated single-use conductivity, pH, UV, and temperature sensors |
| Fluidic Path | Pre-sterilized, gamma-irradiated disposable flow path kits |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA ready™ |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AKTAcrossflow |
| Application Scope | Lab-scale to process-development TFF for protein purification, cell harvesting, UF/DF, and membrane screening |
| Max Total Membrane Area | 150 cm² (3 × 50 cm² cassettes) |
| Minimum Working Volume | 25 mL |
| Control Software | UNICORN v7.x or later |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Fluid Path Materials | USP Class VI-certified elastomers, 316L stainless steel (pump head, valves), single-use compatible |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ avant 150 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.01–150 mL/min (up to 300 mL/min in column packing mode) |
| Flow Accuracy | ±1.5% (1.0–150 mL/min, <3 MPa, 0.8–2 cP) |
| Precision | RSD <0.5% |
| Detection Range | UV-Vis detector (190–700 nm, multi-wavelength monitoring), Conductivity detector (0.01–999.99 mS/cm), pH detector (0–14, accuracy ±0.1 pH units within pH 2–12) |
| Pressure Range | 0–5 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours of in-place cleaning per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ go |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.01–25 mL/min |
| Flow Accuracy | ±2% (at 0.25–25 mL/min, 0.7–3 cP) |
| Detection Options | UV monitor (280 nm fixed wavelength), Conductivity monitor (0.01–999.99 mS/cm), pH monitor (range 0–14, accuracy ±0.1 pH units within pH 2–12, ±3°C from calibration temperature) |
| Pressure Range | 0–5 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning per day |
| External Detector Support | Fluorescence detector, refractive index detector, and other third-party detectors |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ pure 25M |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.001–25 mL/min (up to 50 mL/min in column packing mode) |
| Flow Rate Accuracy | ±1.2% (accuracy), RSD <0.5% (precision |
| conditions | 0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| Detection Range | UV detector (190–700 nm multi-wavelength for M-series), conductivity detector (0.01–999.99 mS/cm), pH detector (0–14 range, ±0.1 pH unit accuracy within pH 2–12), optional external detectors (fluorescence, refractive index) |
| Pressure Range | 0–20 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours CIP per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ pure micro |
| Purification Principle | Gel Filtration Chromatography (GFC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.001–25 mL/min |
| Flow Accuracy | ±1.2% (absolute), RSD <0.5% (0.25–25 mL/min, <3 MPa, 0.8–2 cP) |
| UV Detection Range | 190–700 nm (multi-wavelength) |
| Conductivity Range | 0.01–999.99 mS/cm |
| Optional pH Sensor | 0–14 pH, ±0.1 pH (pH 2–12) |
| Pressure Range | 0–20 MPa |
| Solvent Compatibility | Compatible with 1 mol/L NaOH and 2 mol/L NaCl for ≥3 h in-place cleaning |
| Internal System Volume | As low as 18 µL (with micro kit) |
| Microfluidic Components | 0.8 µL injection valve, 2.6 µL UV flow cell, 5.4 µL conductivity cell, 0.7 µL outlet valve, 0.6 mL mixer, tubing ID: 0.13 mm or 0.25 mm |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | ÄKTA™ start |
| Purification Principle | Affinity Chromatography (AC) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.5–5 mL/min |
| Flow Accuracy | ±15% at ≤1 mL/min |
| Flow Precision | ±15% at ≤1 mL/min |
| Detection | UV Monitor (280 nm single-wavelength), Conductivity Monitor |
| Pressure Range | 0–0.5 MPa |
| Conductivity Range | 0–300 mS/cm |
| Solvent Compatibility | Compatible with in-place cleaning using 1 mol/L NaOH and 2 mol/L NaCl for ≥3 hours per day |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ÄKTA™ start |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | BioProcess pcc 1/2" |
| Control Software | UNICORN™ or DeltaV™ |
| Column Configuration | 3-column (3C) or 4-column (4C) |
| Application | Continuous downstream purification of therapeutic proteins |
| Compliance Framework | Supports FDA 21 CFR Part 11, GMP, and GLP audit trails via software configuration |
| Service Support | OptiRun™ lifecycle service packages available |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | UniFlux™ |
| System Variants | UniFlux™ 10, 30, 120, 400 |
| Membrane Area Range | 0.11–52 m² |
| Feed Volume Capacity | 1–10,000+ L |
| Construction Materials | 316L Stainless Steel, USP Class VI Polymers |
| Control Software | UNICORN™ v7.x or later |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP/GLP-Ready, cGMP-Compatible Design |
| Pressure Monitoring | 4 Real-Time Channels |
| Sensor Integration | Temperature, UV Absorbance, pH, Conductivity, Air Flow, Transmembrane Pressure (TMP), Differential Pressure (ΔP), Crossflow & Permeate Flow Rates |
| Pump Types | Sanitary Diaphragm & Rotary Lobe Pumps |
| Integrity Test | Integrated Air Flow-Based Filter Integrity Testing |
| Cleaning | Fully Automated CIP Method Development & Water Flux Validation |
| Data Management | Audit Trail, Electronic Signatures, 10-Tier User Access Control, Logbook Generation |