| Brand | Drick |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DRK-104 |
| Price | USD 4,200 (FOB) |
| Standard Compliance | ISO 3036, GB/T 2679.7–2005 |
| Measurement Unit | Joules (J) |
| Display | LCD with Chinese GUI |
| Output | Thermal line printer |
| Control System | Microprocessor-based embedded control |
| Sample Clamping | Spring-loaded dual-plate pneumatic-free mechanical clamp |
| Safety Mechanism | Interlocked release handle with automatic reset |
| Energy Range | 0.1–10 J (typical for corrugated board testing) |
| Resolution | 0.01 J |
| Repeatability | ≤±1.5% RSD (per ISO 3036 verification protocol) |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP622 |
| Key Specifications | Load Range 0–50 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Test Speed | 25 mm/min (adjustable 0–300 mm/min) |
| Sample Size | 75 mm × 75 mm |
| Clamp Aperture | Ø35 mm |
| Probe | Hemispherical, compliant with YY/T 0681.13–2014 |
| Dimensions | 330 × 335 × 550 mm |
| Weight | ~55 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Jihengpin |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HP622 |
| Compliance | YY/T 0681.13–2014, ASTM F1306–2016 |
| Force Range | 0–50 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Test Speed | 25 mm/min (adjustable 0–300 mm/min) |
| Sample Size | 75 mm × 75 mm |
| Clamp Aperture | Ø35 mm |
| Probe | Hemispherical, compliant with YY/T 0681.13 |
| Dimensions | 330 × 335 × 550 mm |
| Weight | ~55 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | Jiubin |
|---|---|
| Model | JB-117A-F |
| Origin | Shanghai, China |
| Application | Packaging & Aerospace Composite Materials Testing |
| Max Load Capacity | 20 kN / 50 kN (selectable) |
| Effective Test Height | 1000 mm |
| Effective Test Width | 380 mm (customizable) |
| Force Accuracy | ±0.5% of full scale |
| Displacement Resolution | 0.001 mm |
| Speed Range | 0.001–500 mm/min |
| Force Resolution | 1/500,000 |
| Power Supply | AC 220 V, 50 Hz |
| Weight | ~350 kg |
| Operating Temperature | –20 ± 2 °C or 22 ± 5 °C (ambient) |
| Origin | Spain |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 060101 |
| Price | Upon Request |
| Energy Range Options | 0–6 J (0.003 J resolution) |
| Pendulum Angle | 90° arc |
| Impact Tip Geometry | Triangular pyramid (ISO 3036-compliant) |
| Display Accuracy | ±0.1 J |
| Adjustable Clamp Pressure | Yes |
| Data Interface | RS-232 |
| Power Supply | 230 V, 50 Hz |
| Dimensions (W×D×H) | 860 × 365 × 620 mm |
| Weight | 250 kg |
| Software Compatibility | REGISTRA III data acquisition and statistical analysis suite |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | TSL-1002 |
| Load Capacity Options | 50 N, 100 N, 250 N, 500 N, 1000 N, 2000 N |
| Test Speed Range | 0.1–1000 mm/min (software-controlled, infinitely variable) |
| Stroke | 1000 mm |
| Displacement Resolution | 0.01 mm |
| Clamp Width (standard) | 30 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (L×W×H) | 380 × 450 × 1309 mm |
| Net Weight | 92 kg |
| Accuracy Class | Better than Grade 0.5 |
| Compliance Standards | GB/T 3923.1–2013, GB/T 17200, ISO 37, ASTM D882, ASTM D1938, ASTM F88, EN ISO 11600, JIS P8113 |