Purification Equipment
Filter
Showing 241–270 of 360 results
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Vacuum Centrifugal Concentrator |
| Temperature Range | 10–40 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Maximum Sample Volume per Position | 120 mL |
| Sample Capacity | 1–6 parallel positions |
| Final Absolute Vacuum | 8 mbar |
| Cooling Circulator Range | −10 to +25 °C |
| Vacuum Pump Flow Rate | 3 L/min at 0.6 bar |
| Vacuum Pump Speed Control | Yes |
| Rotational Agitation | 0–600 rpm |
| Tail Tube Volumes Supported | 0.3, 1, or 3 mL |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | VNH-1200 |
| Instrument Category | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 150 °C |
| Sample Capacity | 5–120 mL per tube (12-position) |
| Final Absolute Vacuum | 8 mbar |
| Vacuum Pump Flow Rate | 1.8 m³/h |
| Condenser Cooling Range | −10 °C to +25 °C |
| Programmable Temperature Profile | 9-step gradient (0–10 h per step) |
| Vortex Agitation Speed | 0–600 rpm |
| Tail-Tube Volumes | 0.3 mL / 1 mL / 3 mL |
| Control Interface | Touchscreen LCD |
| Power Supply | 220–240 V, 50/60 Hz, Max 1500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–6 / 12 (standard), up to 48 (customizable) |
| Final Absolute Vacuum | 30 mbar |
| Solvent Recovery | Integrated Condensation System |
| Vacuum Pump Flow Rate | 30 L/min |
| Cooling Circulator Range | 10 °C to Ambient |
| Programmable Temperature Profile | 6-step, 0–10 h per step |
| Vortex Agitation Speed | 0–250 rpm |
| Tail-tube Volumes | 0.3 / 1 / 3 mL |
| Heating Method | Selectable Metal Bath or Water Bath |
| Power Supply | 220–240 V, 50/60 Hz, Max 2200 W |
| Control Interface | PC-based Software with Audit Trail |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–48 positions (standard: 24) |
| Final Absolute Vacuum | 30 mbar |
| Condensate Recovery | Integrated |
| Heating Options | Metal Bath or Water Bath (selectable) |
| Programmable Stages | 6-step gradient temperature control (0–10 h per stage) |
| Rotational Speed | 0–250 rpm |
| Solvent Recovery Efficiency | >95% |
| Cooling Circulator Compatibility | 10 °C to ambient |
| Vacuum Pump Flow Rate | 30 L/min |
| Power Supply | 220–240 V, 50/60 Hz |
| Max Power Consumption | 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–48 positions (6/12 standard, 24/48 optional) |
| Vacuum Range | 30 mbar to atmospheric pressure |
| Vortex Speed | 0–250 rpm |
| Cold Trap Condensation | Integrated |
| Solvent Recovery | Yes |
| Heating Options | Metal Bath or Water Bath (selectable) |
| Final Volume Precision | 0.3 / 1 / 3 mL tail-tube options |
| Power Supply | 220–240 V, 50/60 Hz, max 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity Options | 80 mL, 100 mL, 120 mL, or 500 mL (120 mL standard) |
| Throughput | 16 or 36 samples (configurable) |
| Heating Platform Range | Ambient to 90 °C |
| Vacuum Range | 20 mbar to atmospheric pressure |
| Vortex Shaking Speed | 0–300 rpm |
| Programmable Temperature Profiles | Up to 9-step gradient control |
| Timer Range | 0–10 hours |
| Vacuum Pump Flow Rate | 30 L/min |
| Power Supply | 220–240 V, 50/60 Hz |
| Max. Power Consumption | 2200 W |
| Control Interface | Touchscreen LCD |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | VNH-300 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Channel | 250 mL |
| Final Volume Setpoint Range | 0–1 mL |
| Heating Method | Dry Block Heating |
| Number of Channels | 6 |
| Maximum Gas Flow per Channel | 10 L/min |
| Control Interface | Touchscreen HMI |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-500 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ≤ 0.5 °C |
| Sample Capacity per Vial | 10–80 mL |
| Maximum Simultaneous Samples | 72 (customizable) |
| Gas Flow Rate | Up to 15 L/min (N₂ or inert gas) |
| Heating Method | Water Bath |
| Operating Modes | Manual / Method-Based / Timer-Based |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-600 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Vessel Capacity Options | 80 mL, 100 mL, 120 mL, 500 mL (120 mL standard) |
| Sample Throughput | 6 / 24 / 48 positions |
| Compatible Tube Volume | 1.5–200 mL |
| Heating Method | Water Bath |
| Gas Source | Nitrogen or Inert Gas |
| Max Gas Flow Rate | 15 L/min |
| Endpoint Detection | Infrared-based Quantitative Termination |
| Gas Flow Control | Independent per-channel with on/off valve |
| Airflow Design | Vortex-shear gas delivery |
| Safety Features | Real-time overheat/overpressure/low-water-level alerts |
| Viewing Window | Triple-side optical-grade transparent acrylic |
| Illumination | Adjustable 4-color LED bath lighting |
| Condensation Prevention | High-capacity axial exhaust fan |
| Brand | LabTech |
|---|---|
| Model | AutoClean |
| Origin | Beijing, China |
| Equipment Type | Gel Purification System |
| Compliance | EPA Method 3640 |
| Application Scope | Pesticide Residue Analysis, Lipid- and Fat-Rich Matrix Cleanup, Macromolecule/Small-Molecule Fractionation |
| Configurable Integration | Compatible with Quantitative Concentration and Automated SPE Modules |
| Column | Pre-packed Stainless Steel GPC Column |
| Pump | Dual-Piston Precision Solvent Delivery Pump with Dampener |
| Detector | Variable-Wavelength UV Detector (UV-VIS) |
| Sample Handling | Full-Loop Injection Mode (≤10 mL), Auto-Sampling with Septum-Puncture Capability |
| Pressure Monitoring | Real-Time Pressure Sensing with Over-Pressure Alarm and Pressure Relief Function |
| Automation Platform | High-Accuracy 3-Axis Robotic Positioning System for Injection and Fraction Collection |
| Solvent Efficiency | Optimized Flow Path Design Reduces Solvent Consumption by >30% vs. Manual GPC |
| Column Protection | Integrated Back-Pressure Regulation Extends Analytical Column Lifespan in Downstream GC/HPLC Applications |
| Software | PC-Based Control with Audit Trail, Method Archiving, and Run Log Export (21 CFR Part 11 Ready) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | EV400VAC |
| Capacity | Custom-configurable (standard flask sizes: 50–4000 mL) |
| Ultimate Vacuum | ≤5 mbar (with integrated diaphragm vacuum pump) |
| Rotation Speed | 20–280 rpm (digital PID-controlled, ±1 rpm repeatability) |
| Bath Temperature Range | Ambient to 180 °C (oil bath) / Ambient to 99 °C (water bath) |
| Temperature Control Accuracy | ±0.5 °C |
| Condenser Surface Area | 1,200 cm² (vertical dual-layer coiled condenser with PTFE-coated cooling jacket) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | Flex-MVP |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 16-position |
| Sample Vial Compatibility | 200 mL, 50 mL, 40 mL (and other standard formats) |
| Sealing Architecture | Dual-mode (bulk + individual vial sealing) |
| Condensation System | Dual-tower cold trap for solvent vapor and off-gas recovery |
| Control Interface | 10-inch capacitive touchscreen with real-time parameter adjustment and gradient curve visualization |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | GPC 1000 |
| Flow Rate | 0.1–20 mL/min |
| Maximum Pressure | ≥20 MPa |
| Flow Stability (RSD) | ≤0.5% |
| Auto-sampling Volume | 0.1–100 mL |
| Sample Capacity | Up to 60 vials per run (standard 4–12 mL vials) |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | GPC 600 UP |
| Flow Rate | 0–50 mL/min |
| Maximum Pressure | 42 psi |
| Flow Stability | ±0.1% RSD |
| Auto-Sampling Volume Range | 0–10 mL |
| Auto-Sampling Capacity | 1 position |
| Detection | Variable-Wavelength UV Detector |
| Collection Platform | Precision XYZ Robotic Arm with Septum-Piercing Capability |
| Pump Type | High-Accuracy Dual-Piston Solvent Delivery Pump |
| Software | Graphical User Interface with Role-Based Access Control and Audit-Trail-Enabled Data Logging |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LabTech |
|---|---|
| Model | GPC1000 |
| Origin | Beijing, China |
| Equipment Type | Automated Gel Purification System |
| Pump Configuration | Dual-piston series solvent delivery pump |
| Detection | Variable-wavelength UV detector (standard) |
| Autosampler | 3D robotic arm with immersion-style needle wash (external & internal) |
| Fraction Collector | Independent 3D positioning collector |
| Column Design | Quick-connect stainless-steel GPC columns with automatic column lock valve |
| Sample Handling | Sealed-loop loading and sealed fraction collection |
| System Architecture | Modular, field-upgradable platform |
| Compliance Ready | Designed for GLP-compliant workflows with audit-trail-capable software logging |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | GPC600 mini |
| Flow Rate | Not specified by manufacturer |
| Maximum Operating Pressure | Not specified by manufacturer |
| Flow Stability | Not specified by manufacturer |
| Auto-Sample Injection Volume | Not specified by manufacturer |
| Auto-Sample Capacity | Not specified by manufacturer |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum-Assisted Parallel Nitrogen Concentrator |
| Temperature Range | 15–35 °C (ambient operating range) |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Vial Capacity | 0.5 mL and 1 mL (optical endpoint detection) |
| Max Channel Count | 64 |
| Heating Method | PTC-heated water bath with internal circulation |
| Display | 8-inch HD touch screen (800×480 resolution) |
| Power Supply | 220 V / 110 V, 50 Hz |
| Rated Power | 2200 W |
| Nitrogen Input Pressure Range | 7–145 psi |
| Output Pressure Range | 0–72.5 psi |
| Gas Flow Control | Electromagnetically actuated per-channel valves with calibrated needle valves and real-time pressure display |
| Sensor Technology | Fiber-optic level detection for automatic endpoint termination at 0.5 mL or 1 mL |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Leichi UPW |
| Pricing | Available Upon Request |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count & Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | UPW-B-N30 |
| Price Range | USD 1,400 – 2,100 (FOB Shanghai) |
| Purified Water Grade | ASTM Type I Reagent Water |
| Resistivity | ≥18.2 MΩ·cm at 25 °C |
| Production Rate | 30 L/h |
| Feed Water Conductivity | <400 µS/cm |
| Feed Temperature | 5–40 °C |
| Feed Pressure | 0.1–0.4 MPa |
| RO Salt Rejection | >95% |
| Bacterial Reduction | >99% |
| TOC | ≤30 ppb |
| Particulate Count | <1 particle/mL @ ≥0.22 µm |
| Microbial Limit | ≤1 CFU/mL |
| Flow Rate (Ultrapure) | 1–1.5 L/min |
| Display | LCD with real-time resistivity, temperature-compensated conductivity, system status, and tank level indicators |
| Brand | LeiCi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UPW |
| Price Range | USD 700–1,400 |
| Purified Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm at 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MD Deammonification Technology |
| Pricing | Available Upon Request |
| Application | Ammonia-Nitrogen Removal from Wastewater |
| Brand | Michem |
|---|---|
| Model | MW-D10 |
| Origin | Beijing, China |
| Product Category | Domestic |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 10–18.25 MΩ·cm |
| Total Organic Carbon (TOC) | ≤10 ppb |
| Particles (>0.1 µm) | ≤1 particle/mL |
| Power Supply | Standard AC outlet |
| Feed Water Requirement | Municipal tap water, conductivity ≤550 µS/cm |
| Filtration Stages | 6-stage integrated purification |
| UV Wavelength | 185/254 nm dual-lamp system |
| Output Options | Dual independent streams — purified water & ultra-pure water |
| Compliance | ASTM D1193, CLSI (formerly NCCLS) Grade I, CAP Laboratory Standards, NSF/ANSI 58 & 61 certified components (Dow Filmtec™ & Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane Systems/Koch Membrane...... (truncated for brevity |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Micro-Tac |
| Sample Processing | Wastewater Treatment |
| Core Technology | Integrated Fenton-based Advanced Oxidation Process (AOP) with Microwave Acceleration and Rare-Earth Metal Catalyst |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-I |
| Distillation Temperature Range | 0–400 °C |
| Receiver Bath Temperature Control | 0–60 °C (±0.1 °C) |
| Cold Bath Temperature Control | 0–60 °C (±0.1 °C) |
| Heating Power | 0–1200 W (continuously adjustable) |
| Total Power Consumption | 2000 W |
| Input Voltage | 220 V ±10%, 50 Hz ±1 Hz |
| Display | 10.4″ integrated LCD touch screen |
| Interface Ports | USB, RS-232, Ethernet |
| Volume Measurement Points | 99 programmable recovery points |
| Refrigeration Method | Semiconductor cooling |
| Compliance | GB/T 6536–2010, ISO 3405, ASTM D86, IP 123, SY/T 5648 |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Model | SYP-7534B |
| Origin | Shanghai, China |
| Construction | Quartz-glass distillation apparatus |
| Cold Bath Temperature Control Range | −10 °C to +70 °C |
| Condensate Cylinder Temperature Control Range | −10 °C to +60 °C |
| Volume Detection Range | 0–100 mL (0.01 mL resolution) |
| Volume Measurement Accuracy | < 0.1 mL |
| Distillation Rate | 4–5 mL/min |
| Heating Power | Up to 1200 W (programmable ramp control) |
| Refrigeration | Imported German compressor |
| Temperature Sensor | Pt100 glass probe (IEC 60751 Class A) |
| Liquid Level Detection | Infrared photoelectric system |
| Display | 12.1″ embedded color touch screen |
| Data Storage | 100 test records |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 1500 W |
| Operating Ambient | 10–40 °C |
| Storage Ambient | 0–50 °C |
| Atmospheric Pressure Compensation | Integrated barometric sensor with real-time correction |
| Safety Features | Flame detector with automatic fire suppression |
| Compliance Standards | GB/T 7534, GB/T 615, GB 338–2011, GB/T 6536 |
| Brand | Miura |
|---|---|
| Origin | Japan |
| Model | GO-2EHT |
| Certification | EN 61010-1, UL 61010-1:2012, CAN/CSA C22.2 No. 61010-1-12:2012, EN 55011:2009+A1:2010, EN 61000-6-2:2005, RoHS Directive 2011/65/EU, IEC 62321, BS EN IEC 63000:2018 |
| Solvent Consumption per Sample | <100 mL (90 mL n-hexane + 5 mL toluene) |
| Final Fraction Volume | 1–2 mL |
| Brand | Miura |
|---|---|
| Origin | Japan |
| Model | GO-4EHT |
| Certification | EN 61010-1, UL 61010-1:2012, CAN/CSA C22.2 No. 61010-1-12:2012, EN 55011:2009+A1:2010, EN 61000-6-2:2005, RoHS Directive (EU) 2015/863, IEC 62321, BS EN IEC 63000:2018 |
| Purification Principle | Thermally Enhanced Solid-Phase Extraction (SPE) with Chemically Modified Silica |
| Solvent Consumption per Sample | ≤90 mL n-Hexane + 5 mL Toluene |
| Final Fraction Volume | 1–2 mL |
| Flow Path Architecture | Valve-Free, Disposable Cartridge-Based |
| Channel Configuration | Independent or Simultaneous Operation of 4 Channels |
| Method Flexibility | User-Defined Method Editing Supported |
| Compliance Context | Designed for GLP-compliant dioxin analysis workflows aligned with EPA Method 1613B, EN 1948, and ISO 18073 |
| Brand | Muira/MIURA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GO-6EHT |
| Pricing | Upon Request |
| Brand | New Biolink |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MVR Evaporator Technology |
| Pricing | Upon Request |
| Sample Processing | Industrial Wastewater Treatment |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | N4R-1.0-50 |
| Price Range | USD 4,200–7,000 (FOB) |
| Water Flow Rate | 100–1000 L/h |
| Controllable Resistivity Range | 0.15–1.7 MΩ·cm |
| Control Accuracy | ±0.03 MΩ·cm |
| Max. Inlet Water Pressure | 0.5 MPa |
| Pressure Drop | 0.06 MPa at 3000 L/h |
| Connection Ports | 3/4″ female screw |
| Power Supply | AC 100–130 V / 220–240 V, 50/60 Hz, single-phase, 1 A |
| Enclosure Type | Rack or Cabinet |
| H₂O₂-Compatible Sterilization | Yes (3% hydrogen peroxide) |