Radiation Measurement Instruments
Filter
Showing 61–90 of 106 results
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | FD216 |
| Sampling Method | Active Pump-Driven Sampling |
| Measurement Range (Air Radon) | 3–100,000 Bq/m³ |
| Minimum Detectable Activity | 3 Bq/m³ |
| Response Time (Air) | 30 min |
| Detector | ZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT) |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| Stability | ≤10% drift over 8 h |
| Power Supply | Rechargeable Li-ion Battery (30 h continuous operation) or AC Adapter |
| Operating Temperature | −10 to +40 °C |
| Relative Humidity | ≤90% at +40 °C |
| Data Storage Capacity | 2000 records |
| Display | LCD |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Brand | SENBE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | SEN-ABR50 |
| Instrument Type | Portable |
| Measurement Target | Solid Surfaces |
| Detector Technology | Plastic Scintillation Detector (Alpha/Beta/Gamma Discriminative) |
| Energy Response | Alpha (≥3 MeV), Beta (≥150 keV), Gamma (≥50 keV) |
| Display | Backlit LCD |
| Alarm | Adjustable Threshold with Real-Time Background Compensation |
| Power Supply | Rechargeable Li-ion Battery (≥12 h continuous operation) |
| Compliance | Meets IEC 60846-1:2014 and GB/T 10257–2022 for portable radiation contamination monitors |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | NHT-310 |
| Pricing | Upon Request |
| Frequency Range | DC – 40 GHz |
| Display | Monochrome backlit LCD (128 × 64 pixels, 7 cm diagonal) |
| Refresh Rate | 200 ms |
| Measurement Units | mW/cm², W/m², V/m, A/m, Tesla |
| Result Modes | Actual, MAX, AVG, Median, X/Y/Z instantaneous |
| Data Storage | 21,504 samples (21,000 typical) |
| Logging Duration | >24 h at 5 s interval |
| Battery Life | ~72 h (backlight off) |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +70 °C |
| Humidity | 5–95% RH (non-condensing) |
| Dimensions (host) | 160 × 98 × 30 mm |
| Weight (host) | 500 g |
| Housing | Magnesium-aluminum alloy |
| Integrated Sensors | Temperature, GPS (optional) |
| Analog Outputs | X/Y/Z SMA female connectors |
| Digital Interface | Full-duplex serial fiber optic port |
| Probe Interface | Plug-and-play LEMO™ with automatic recognition |
| Software | MicroLink (Windows XP/7/Vista/8) |
| Calibration Interval | 24 months |
| Probe Options | PROBE 01E (100 kHz – 6.5 GHz), PROBE 11E (5 Hz – 400 kHz), PROBE 10B (5 Hz – 400 kHz) |
| Brand | Starwood |
|---|---|
| Model | SMP620 |
| Category | Electromagnetic Field Strength Analyzer |
| Frequency Range | DC to 300 GHz (probe-dependent) |
| Electric Field Measurement Range | Up to 100 kV/m (with appropriate probe) |
| Magnetic Field Measurement Range | Up to 10 T (with appropriate probe) |
| Accuracy | ±1.5% (typical, probe- and frequency-dependent) |
| Data Storage | 4 GB internal (expandable) |
| Sampling Interval | 0.5 s to 100 h (1 s step) |
| Display Units | V/m, kV/m, µW/cm², mW/cm², W/m², nT, µT, mT, T, A/m, mG, % of exposure limit |
| Compliance Support | ICNIRP, IEEE C95.1, GB 8702–2014, EN 50492, EN 62233 |
| Brand | TaiKun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TK-GEM50P4-83-RB-SMP |
| Instrument Type | Laboratory Gamma Spectrometer |
| Detector Type | P-type Coaxial High-Purity Germanium (HPGe) |
| Measurement Mode | Gamma-ray Spectrometry |
| Sample Form | Solid |
| Energy Range | 30 keV – 10 MeV |
| Relative Efficiency | ≥50% @ 1.33 MeV |
| Energy Resolution (FWHM) | ≤0.85 keV @ 122 keV, ≤1.8 keV @ 1.33 MeV |
| Peak-to-Compton Ratio | ≥53 |
| Peak Shape (FW.02M/FWHM) | ≤3.0 |
| Cooling Method | Electromechanical Cryocooler (Pulse Tube) with 25 L LN₂ Dewar |
| Shielding | Dual-layer low-background lead chamber (15 cm Pb + Cu/Sn lining) |
| Software Compliance | Supports FDA 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD MK2 |
| Instrument Category | Dose/Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation Types | X-ray, γ-ray, and β-particle radiation |
| Detector Type | Multi-stage solid-state detector |
| Measurement Quantities | Ambient dose equivalent H*(10), personal dose equivalent Hp(10) (deep/body), and Hp(0.07) (shallow/skin) |
| Compliance Standards | IEC 61283, IEC 61526, ANSI N13.11, ANSI N13.27, ANSI N42.20 |
| Data Retention | 10 years without battery power |
| Power Supply | Two AA 1.5 V alkaline batteries (8 weeks continuous operation) or one 3.6 V lithium battery (5 months continuous operation) |
| Communication Interface | High-speed infrared (IR) port |
| Alarm Capability | Configurable dose and dose rate thresholds with audible alert |
| Memory Security | Password-protected dose log storage |
| Certification Status | Only electronic personal dosimeter to pass all IAEA 2007 performance tests |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | EPD-N2 |
| Instrument Category | Dose Rate Meter / Personal Dosimeter |
| Form Factor | Portable |
| Radiation Types Measured | Gamma and Neutron |
| Detector Technology | Multi-stage Solid-State Detector |
| Energy Range | 25 keV – 10 MeV (photons), Thermal neutrons – 15 MeV (neutrons) |
| Dose Quantity Displayed | Ambient and Personal Dose Equivalent Hp(10) |
| Compliance | IEC 61526 Ed. 4.0 (2018), ANSI N42.20, ISO 15265:2022 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FH 40 G NBR |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Type | X-ray and Gamma (γ) |
| Detector Architecture | Dual-detector (NaI(Tl) scintillator + plastic scintillator) with NBR (Natural Background Reduction) patented technology |
| Measurement Range | 1 nSv/h – 100 µSv/h |
| Sensitivity | 2000 s⁻¹/µSv/h |
| Energy Response Range (Probe FHZ 672E-10) | 48 keV – 6 MeV |
| Detection Limit | <20% of typical natural background dose rate |
| Host Unit (FH 40 GL-10) | Energy Range: 30 keV – 4.4 MeV |
| Host Measurement Range | 10 nSv/h – 100 mSv/h |
| Host Sensitivity | 2 s⁻¹/µSv/h |
| Host Weight (excl. batteries) | 410 g |
| Battery Life | >250 h (standalone), >30 h (with FHZ 672E-10 connected) |
| Data Handling | Onboard storage, USB interface, PC configuration & data download capability |
| Signal Processing | ADF (Advanced Digital Filtering) adaptive algorithm |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate and Integrated Dose Meter |
| Detector Compatibility | Interchangeable (NaI(Tl), He-3 neutron, GM, scintillation, or proportional detectors) |
| Measurement Range Extension | Up to 4 m via modular fiberglass telescopic pole |
| Weight | 2.6 kg |
| Compliance | Meets IEC 60846-1:2014, IEC 61526:2010, and EURATOM Basic Safety Standards Directive 2013/59 |
| Software Interface | USB and Bluetooth connectivity for real-time data logging and remote monitoring via Thermo Fisher RadEye Suite |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | FHT 1377 PackEye |
| Instrument Category | Dose Rate Meter |
| Portability | Portable |
| Measured Radiation Types | Gamma and Neutron |
| Detector Configuration | Dual Plastic Scintillator + Two He-3 Proportional Counters |
| Dose Rate Range | 50 nSv/h – 2 mSv/h |
| Sensitivity | 50 nSv/h |
| Power Consumption | 350 mW |
| Battery Life | ~70 h (7.2 V, 3600 mAh rechargeable Li-ion) |
| Dimensions | 58 cm (H) × 30 cm (W) × 18 cm (D) |
| Weight | 6 kg |
| Data Update Interval | 100 ms |
| LED Indication | 10-level gamma / 10-level neutron |
| Communication | Bluetooth + GPS interface |
| Compliance | IAEA-recommended system for orphan source search |
| Key Technology | Patented Natural Background Rejection (NBR), Digital Filtering, Low-Power Embedded Electronics |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Dose Rate Meter |
| Model | FHT 40NBR |
| Detector Configuration | Dual-detector (NaI(Tl) scintillation crystal + plastic scintillator) |
| Measurement Principle | Gamma photon energy discrimination via pulse-height analysis and NBR (Natural Background Rejection) algorithm |
| Compliance | Designed for field-deployable radiological survey per IEC 60846-1:2014, ANSI N42.33, and EURATOM Directive 2013/59/Euratom |
| Data Interface | USB and Bluetooth® 4.0 |
| Storage Capacity | Up to 10,000 timestamped dose rate records |
| Operating Temperature | –10 °C to +50 °C |
| IP Rating | IP67 |
| Battery Life | >100 hours (alkaline) or >200 hours (rechargeable Li-ion) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Harshaw TLD 4500 |
| Instrument Category | Radiation Dosimetry System |
| Instrument Form Factor | Benchtop (Not Portable — Corrected per Technical Specification) |
| Measured Radiation Types | Photons (>1 keV), Neutrons (thermal to 100 MeV), Electrons (>70 keV) |
| Dynamic Range | 7 decades |
| Readout Time | <35 s (2-element card), <60 s (4-element card) |
| Linearity | ±1% deviation |
| Reference Light Stability | <1% variation over 10 consecutive reads |
| Glow Curve Heating Profile | Preheat 0–100 s, Ramp Rate 1–30 °C/s, Max Temp 300 °C (Teflon), 400 °C (Kapton), 600 °C (metal disk) |
| Dose Range (metal-disk heating) | 10 µGy–1 Gy (linear), 1–20 Gy (supralinear) |
| Reusability | 500 cycles (TLD-100 chips), 50 cycles (extremity rings) |
| Operating Temperature | 0–40 °C |
| Dimensions | 370 H × 460 W × 500 D mm |
| Weight | 35 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Laboratory-Based TLD Reader |
| Model | Harshaw TLD 5500 |
| Detector Type | Cooled Photomultiplier Tube (PMT) |
| Sample Capacity | Up to 50 TLD chips per cycle |
| Heating Method | Gas-Heated Linear Ramp (TTP) |
| Max Temperature | 600 °C |
| Linearity | ±1% deviation |
| Dynamic Range | 7 decades |
| Preheat Time | 30 min |
| High Voltage Range | 500–1200 V |
| HV Stability | ±0.005% |
| Dose Units | nC, µGy, mGy, Gy, mrad, mrem, µSv, mSv, Sv |
| Dark Current Equivalent | <50 mGy (Cs-137) |
| MTBF | >10,000 hours |
| Operating Temp | 0–40 °C |
| Storage Temp | −10–60 °C |
| Compliance | Designed for ISO/IEC 17025-accredited dosimetry laboratories |
| Software | Harshaw TLD Analysis Suite with audit trail and 21 CFR Part 11 readiness |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Thermoluminescent Dosimeter (TLD) Reader |
| Model | Harshaw TLD 6600 |
| Detector Type | TLD Reader |
| Radiation Types Measured | Photons (X-rays, γ-rays), Neutrons |
| Measurement Scope | Personal Dose, Environmental Dose |
| Linear Dose Range | Up to 20 Sv |
| Compliance | IEC 61066, ISO 14146, ANSI N13.32 |
| Operating Mode | Benchtop (not portable — corrected per technical specification) |
| Calibration | Automated, Traceable to NIST Standards |
| Quality Control | Built-in QC routines with pass/fail reporting |
| Light Sensitivity | Immune to ambient light interference (non-OSL design) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM11 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Type | Portable |
| Measurement Target | Human Hands and Feet |
| Detector Type | High-Performance Scintillation-Based Hand/Foot Probe Array |
| Measurement Mode | Surface Radioactive Contamination Screening |
| Sensitivity | High (optimized for low-level β/γ emitters, e.g., ⁹⁰Sr/⁹⁰Y, ¹³⁷Cs, ⁶⁰Co) |
| Compliance | IEC 61098:2017 (Radiation Protection Instrumentation — Hand and Foot Contamination Monitors) |
| Display | Large-area capacitive touchscreen LCD |
| Power Consumption | Low (<5 W standby, <12 W operational) |
| Data Storage | Internal non-volatile memory (≥10,000 measurement records with timestamp, operator ID, and location tag) |
| Calibration | Automated self-calibration routine with reference source verification |
| Optional Configuration | Integrated whole-body contamination probe module (for supplementary torso/leg screening) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | LFM-3 |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Form Factor | Portable |
| Measurement Target | Radioactive Sources and Nuclear Materials |
| Detector Type | Dual NaI(Tl) Scintillation Detectors |
| Energy Channels | Low-, Medium-, and High-Energy Discrimination Channels |
| Detector Housing | Lead-Shielded Enclosure |
| Dimensions | 144 × 455 × 178 mm |
| Weight | 6.7 kg |
| Compliance | Designed for compliance with ANSI N42.33, IEC 60846-1, and applicable ISO 2889 radiation monitoring requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | MDS |
| Instrument Type | Portable Dose Rate Meter |
| Measurement Principle | Scintillation Detection & Neutron Proportional Counting |
| Detector Types | 5-L Plastic Scintillator (Primary), Optional He-3 Neutron Detector |
| Measurement Range | 1 nSv/h – 20 µSv/h |
| Sensitivity | 20,000 cps/µSv/h (for Cs-137) |
| Energy Response | 50 keV – 3 MeV |
| Background Count Rate | ~500 cps |
| Minimum Detectable Increase | ≥2 nSv/h above background |
| GPS | 6-Channel Satellite Receiver with Real-Time Georeferencing |
| Operating Temperature | −20 °C to +55 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| Power Supply | 12 V DC |
| Internal Battery | 8 h continuous operation |
| Enclosure | Zargus MIL-STD-810G Certified Transport Case |
| Weight | 15 kg |
| Dimensions (Detector Unit) | 40 × 60 × 35 cm |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Mini 900 Series |
| Instrument Category | Dose Rate Meter / Radiation Survey Meter |
| Form Factor | Portable / Benchtop Configurable |
| Radiation Types Detected | X-ray and Gamma (γ) Radiation |
| Detector Options | Geiger-Müller (GM) Tube or Scintillation Detector |
| Measurement Principle | Pulse Counting / Analog Voltage Output Integration |
| Display Format | Logarithmic Scale with Simultaneous Background and Net Count Rate Readout |
| Alarm Function | User-Adjustable Threshold with Proportional Audio Feedback |
| Variants | R-Type (General Purpose), G-Type (Gamma-Optimized), D-Type (Dose Rate Calibrated), X-Type (X-Ray Enhanced) |
| Dimensions | 180 mm (W) × 110 mm (D) × 165 mm (H) |
| Weight | 1.0 kg |
| Power Supply | 6 × AA Alkaline or Rechargeable Batteries (Typical Runtime: ~300 hours at 4 hrs/day usage) |
| GM Tube Bias Voltage Range | 300–700 V DC |
| External Power Input | 12–18 V DC |
| High-Voltage Generator Output | 600–1500 V DC |
| Sensitivity | –100 mV negative polarity analog voltage input (for external detector interfacing) |
| Energy Response | Detector-dependent |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye AB100 |
| Instrument Category | Dose Rate / Contamination Meter |
| Form Factor | Portable |
| Detector Type | Zinc-Loaded Plastic Scintillator |
| Active Detection Area | 69 mm × 145 mm (10,005 mm²) |
| Effective Sensitivity Area | 2500 px² (≈ 100 cm² equivalent in operational context) |
| Window Thickness | 0.87 mg/cm² aluminum-coated polymer foil |
| Alpha Efficiency (²⁴¹Am) | 36% |
| Beta Efficiency (⁶⁰Co) | 25% |
| Beta Efficiency (⁹⁰Sr/⁹⁰Y) | 49% |
| Gamma Response (¹³⁷Cs) | ~40 cps per µSv/h |
| Battery Life | Up to 1000 hours on NiMH rechargeable pack |
| Compliance | Meets ANSI N42.33, IEC 60846-1, and ISO 7503-1 for surface contamination monitoring |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RadEye B20 |
| Instrument Type | Portable Radiation Survey Meter |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Detector Type | Thin-window Geiger-Müller (GM) Tube with 44 mm Active Diameter and Adjustable Window Thickness (1.8–20 mg/cm²) |
| Dose Rate Range (γ) | 0–2 mSv/h (RadEye B20) |
| Count Rate Range (Contamination) | 0–10 kcps (B20) |
| Energy Response (with γ energy window) | 17 keV – 3 MeV |
| 2π Detection Efficiency | ²⁴¹Am: 28%, ⁶⁰Co: 25%, ⁹⁰Sr/⁹⁰Y: 36%, ¹⁴C: 19% |
| Calibration Source | 9 g Lutetium Oxide (Lu₂O₃) reference source, activity density 50 Bq/g (1.4 nCi/g) |
| Alarm Modes | Audible, Visual (LED), and Vibratory |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye G-10 |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Measured | X-ray and Gamma (γ) |
| Detector Type | Energy-Compensated Geiger-Müller (GM) Tube |
| Measurement Range | 0.5 µSv/h to 100 mSv/h |
| Energy Response Range | 50 keV to 3 MeV |
| Sensitivity (¹³⁷Cs) | 1.7 cps per µSv/h |
| Compliance | ANSI N42.33-2021, NATO AEP-117 Ed.3 |
| Battery Life | Up to 600 hours on two AAA alkaline cells |
| Environmental Robustness | Vibration-resistant housing, IP65-rated enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye G-EX |
| Instrument Category | Dose Rate Meter |
| Form Factor | Portable |
| Radiation Types Detected | Alpha, Beta, Gamma, Neutron |
| Measurement Range | 0.5 μSv/h – 100 mSv/h |
| Sensitivity (Cs-137, 662 keV) | ~1.7 cps/μSv/h |
| Ingress Protection | IP65 |
| ATEX Certification | II 2G Ex ia IIB T4, IBExU 10ATEX 1096 |
| Weight | 160 g |
| Display | Backlit High-Contrast LCD |
| Alarm Modes | Dual Adjustable Thresholds (Dose & Dose Rate) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Survey Meter |
| Instrument Category | Gamma and Neutron Dose Rate Meter |
| Model | RadEye GN |
| Detection Principle | Dual-channel scintillation detection (CsI:Tl for gamma, LiI(Eu) for thermal neutrons) |
| Gamma Energy Range | 30 keV–1.3 MeV |
| Neutron Sensitivity | Cf-252 source, 4.3 cps per 20,000 n/s |
| Gamma Dose Rate Range (H*(10), energy-compensated) | 0.01 μSv/h–250 μSv/h |
| Gamma Dose Rate Energy Compensation Range | 45 keV–1.3 MeV |
| Neutron Counting Rate | 0.1–1000 cps |
| Dimensions | 96 mm × 61 mm × 31 mm |
| Weight | 160 g |
| Gamma Efficiency | Am-241: 900 cps/(μSv/h), Cs-137: 130 cps/(μSv/h), Co-60: 60 cps/(μSv/h) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye HEC |
| Instrument Category | Dose Rate / Activity Meter |
| Form Factor | Portable |
| Measured Radiation Types | Alpha and Beta Emitters |
| Detector Type | Scintillation Detector (Lu₂O₃-based) |
| Counting Range | Alpha: 1–10,000 cps |
| Beta | 1–100,000 cps |
| Background | Alpha <2 cpm, Beta <70 cpm (under 0.25 µSv/h gamma background) |
| Detector Diameter | 5 cm |
| Detection Efficiency (2π geometry, 50 mm source) | Pu-239 >85%, Am-241 >75%, Tc-99 >45%, Sr/Y-90 >70%, C-14 >20% |
| Sample Chamber Dimensions | 51.6 mm × 9.6 mm |
| Adjustable Sample Height | 3.2–7.9 mm |
| Data Storage | 250 system events (alarms/errors/parameter changes), 4500 full sample records |
| Calibration & Decay Correction | Built-in automated routines |
| Interface | Serial and USB |
| Regulatory Compliance | CE Marked |
| Internal Check Source | 9 g lutetium oxide (¹⁷⁶Lu) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | RadEye NBR |
| Instrument Category | Radiation Survey Meter / Dose Rate Meter |
| Form Factor | Portable |
| Detection Target | Trace Artificial Gamma Emitters |
| Detector Type | Multi-Function NBR Probe (FHZ 674) |
| Measurement Range | 0.01 µSv/h – 100 µSv/h |
| Sensitivity | >1500 cps per µSv/h (at 30 keV) |
| Operating Temperature | −20 °C to +50 °C |
| Dimensions (RadEye SX) | 110 mm × 67 mm × 62 mm |
| Weight (RadEye SX only) | ~160 g (with 2×AA batteries and rubber boot) |
| Weight (FHZ 674 probe + SX) | ~2.8 kg (excluding shoulder strap) |
| Battery Life | ~150 h (with FHZ 674 probe, part #4250693) |
| Data Storage | 1500 measurement records + 250 operation logs |
| Alarm | Dual configurable thresholds (count rate / dose rate), audible alarm ≥80 dB at 30 cm |
| Probe Cable | RG58, up to 1.5 m, MHV connector |
| High Voltage Output | 100–1400 V, 2 MΩ load |
| Compatible Probes | 16 selectable probe types (configurable via HV, calibration factor, dead-time correction, overload threshold, and range) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RadEye NL |
| Instrument Category | Neutron Dose Rate Meter |
| Form Factor | Portable |
| Detector Type | Pressurized He-3 Proportional Counter (2.5 bar) |
| Measurement Range | <0.2 cps (in presence of 10 mSv/h Cs-137 gamma field) |
| Neutron Sensitivity | −0.15 cps per μSv/h (calibrated to Cf-252 neutron source) |
| Background Count Rate | 0.0025 cps (at 300 m elevation) |
| Gamma Rejection Ratio | <0.2 cps for 10 mSv/h Cs-137 |
| Units Displayed | Counts per second (cps) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Personal Radiation Detector (PRD) |
| Detector Type | NaI(Tl) Scintillation Crystal |
| Measurement Principle | Gamma Photon Detection via Scintillation & Pulse Height Analysis |
| Dose Rate Range | 0.01 µSv/h – 250 µSv/h (PRD mode) |
| Extended Range (PRD-ER) | 0.01 µSv/h – 100 mSv/h |
| Energy Response Range | 60 keV – 1.3 MeV |
| Sensitivity | 150 cps/(µSv/h) for ¹³⁷Cs |
| Data Storage Capacity | 1600 dose rate readings with timestamps |
| Ingress Protection Rating | IP65 |
| Operating Temperature | –10 °C to +50 °C |
| Battery Life | Up to 1,000 hours (typical alkaline battery operation) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Survey Meter / Dose Rate Meter |
| Detector Type | NaI(Tl), GM Tube, ZnS(Ag)-Plastic Scintillator, He-3 Proportional Counter |
| Radiation Types Detected | Alpha (α), Beta (β), Gamma (γ), X-ray, Neutron |
| Measurement Modes | Dose rate (μSv/h, mR/h), Count rate (cps), Surface contamination (Bq, Bq/cm², dpm), Spectral identification (RadEye GN+/NBR) |
| Dose Rate Range (RadEye PRD) | 0.01 μSv/h – 250 μSv/h |
| Sensitivity (Cs-137, RadEye PRD) | 150 cps per 1 μSv/h |
| Energy Response | 30 keV – 4 MeV (model-dependent) |
| Compliance | IEC 62533, IEC 62401, ANSI N42.32, ATEX II 2G Ex ia IIB T4 (G-10-Ex) |
| Operating Environment | Field-deployable, battery-powered, ruggedized for industrial, emergency response, and regulatory use |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Radiation Spectrometer |
| Model | RIIDEye |
| Detector Types | NaI(Tl), LaBr₃(Ce), LiI(Eu), CLYC (Cs₂LiYCl₆:Ce) |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 10 nSv/h – 0.1 Sv/h |
| Total Dose Range | 100 nSv – 1 Sv |
| Sensitivity | 3000 cps/μSv/h |
| ADC Resolution | 14-bit fast baseline restoration |
| Spectral Stabilization | K-40-based automatic temperature-compensated stabilization |
| Nuclide Library | ANSI N42.34-compliant library of 88 isotopes (expandable to 125), including ITRAP/IAEA, medical, industrial, SNM, and user-defined nuclides |
| Identification Algorithms | QCC™ Quantitative Composite Comparison and Hysteresis™ pattern-matching technologies |
| Display | 3.5″ color LCD (320×240, 32k colors) |
| Interface | 7-key single-finger keypad, Ethernet or RS-232 |
| Data Storage | ≥10,000 spectra with timestamp, GPS (optional), and full metadata |
| Power | Rechargeable battery or AA cells |
| Environmental Rating | IP67-rated ruggedized enclosure (RIIDEyeX) |
| Compliance | ANSI N42.34, IEC 62327, IEEE 309, MIL-STD-810G |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SAM12 |
| Instrument Category | Dose Rate / Contamination Meter |
| Instrument Form Factor | Portable |
| Detection Target | Gamma-emitting Radionuclides |
| Detector Technology | Co-60–Optimized Scintillation Detection with NBR (Natural Background Rejection) Algorithm |
| Measurement Scope | Discrimination of Artificial vs. Natural Gamma Radioactivity |
| Performance Context | High-reliability detection under elevated natural background radiation conditions |
| Sensitivity | Enhanced for low-level gamma contamination screening |