| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1027 |
| Sampling Method | Active (Pump-Driven) |
| Measurement Range | 0.1–999 pCi/L (3.7–37,000 Bq/m³) |
| Minimum Detectable Concentration | 0.1 pCi/L |
| Sensitivity | 2.5 counts per hour per pCi/L (cph/pCi/L) |
| Accuracy | ±25% or ±1 pCi/L (whichever is greater) |
| Display | 3-digit LCD |
| Power Supply | 220 VAC / 9 VDC adapter |
| Dimensions | 200 × 120 × 65 mm |
| Weight | 0.9 kg |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | JC-RAD-14 |
| Sampling Method | Active Pump-aspiration |
| Measurement Range | Air Radon: 3–150,000 Bq/m³ |
| Soil Radon | 300–400,000 Bq/m³ |
| Radon Exhalation Rate | 0.001–10.000 Bq/(m²·s) |
| Water Radon | 0.003–100 Bq/L |
| Detection Repeatability | ≤5% (at 1800 Bq/m³, 65% RH, 25°C) |
| 8-h Drift | ≤10% |
| Power | Rechargeable Li-ion battery (≥30 h continuous operation) or AC adapter |
| Operating Temperature | −10°C to +40°C |
| Relative Humidity | ≤98% RH |
| Display | Backlit dot-matrix LCD |
| Data Storage | >200,000 records |
| Flow Rate | Up to 3 L/min (peak) |
| Communication Interfaces | USB, RS232, RS485, TCP/IP, Industrial Wireless |
| Inlet/Outlet Fittings | Anodized Aluminum |
| Self-background Count Rate | ≤0.3 cpm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RAD7 |
| Sampling Method | Active Sampling |
| Detection Range | 3.7–74,000 Bq/m³ (0.1–20,000 pCi/L) |
| Minimum Detectable Concentration | 3.7 Bq/m³ (0.1 pCi/L) |
| Sensitivity | 12.8 counts/min per Bq/m³ (air monitoring mode) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD125 |
| Price Range | USD 7,000–14,000 (FOB) |
| Sampling Method | Passive Collection |
| Measurement Range | 0–10 Bq/m³ |
| Minimum Detectable Concentration | 0.01 Bq/m³ |
| Response Time | 300 s |
| Detector Background | ≤100 counts/s |
| Sensitivity Accuracy | ±10% |
| Operating Temperature | 0–45 °C |
| Relative Humidity Limit | ≤95% RH |
| Power Supply | +9–10 V DC for amplifier |
| Weight | 16 kg (excluding scaler unit) |
| Brand | SARAD |
|---|---|
| Origin | Germany |
| Model | RTM 1688-2 |
| Sampling Method | Active sampling |
| Measurement Range | 0–10 MBq/m³ |
| Detection Limit | Not specified (contextually implied as sub-10 Bq/m³ in slow mode) |
| Response Time | 95% in 12 min (fast mode) |
| Flow Rate | 0.30 L/min |
| Detector Type | Integrated semiconductor alpha spectrometer with electrostatic collection chamber |
| Sensitivity | 3 cpm/(Bq/m³) (fast mode) / 7 cpm/(Bq/m³) (slow mode) |
| Chamber Volume | ~250 mL |
| Humidity Independence | Yes, no desiccant required |
| Data Storage | 2047 measurement records |
| Compliance | Designed for ISO 11665 series, ICRP recommendations, and EPA/WHO radon assessment protocols |
| Brand | SARAD |
|---|---|
| Origin | Germany |
| Model | RTM2200 |
| Sampling Method | Active |
| Measurement Range | 0–10,000,000 Bq/m³ |
| Minimum Detectable Concentration | 1 Bq/m³ |
| Response Time | 12 min (Po-214 excluded) / 120 min (Po-214 included) |
| Detector Type | Silicon semiconductor alpha spectrometer with deep ion implantation |
| Sensitivity | 3.2 cpm/(kBq/m³) (Po-214 excluded) / 7 cpm/(kBq/m³) (Po-214 included) |
| Chamber Volume | ~135 mL |
| Built-in Pump Flow Rate | 300–800 mL/min |
| Operating Interface | 240 × 128 pixel graphical touchscreen |
| Data Storage | SD card with GPS tagging (optional) |
| Communication Interfaces | USB, RS232 (supports GSM modem, ZigBee, or Wi-Fi adapter upgrade) |
| Dimensions | 235 × 140 × 255 mm |
| Environmental Sensors (standard) | Air temperature, relative humidity, flow rate, barometric pressure, battery status |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | FD216 |
| Sampling Method | Active Pump-Driven Sampling |
| Measurement Range (Air Radon) | 3–100,000 Bq/m³ |
| Minimum Detectable Activity | 3 Bq/m³ |
| Response Time (Air) | 30 min |
| Detector | ZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT) |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| Stability | ≤10% drift over 8 h |
| Power Supply | Rechargeable Li-ion Battery (30 h continuous operation) or AC Adapter |
| Operating Temperature | −10 to +40 °C |
| Relative Humidity | ≤90% at +40 °C |
| Data Storage Capacity | 2000 records |
| Display | LCD |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Brand | YUFENGRUILIN |
|---|---|
| Model | YFR-105 |
| Measurement Principle | Diffusion-type scintillation cell |
| Detection Range | 5–100,000 Bq/m³ |
| Minimum Detectable Concentration | 5 Bq/m³ |
| Uncertainty | ±15% (k=2) |
| Response Time | ≤30 min (typical), down to 10 min under optimized conditions |
| Power Supply | Rechargeable 5000 mAh Li-ion battery (48 h continuous operation) + AC adapter |
| Operating Environment | −10 °C to +40 °C, ≤90% RH |
| Dimensions | 140 × 170 × 60 mm |
| Weight | 0.8 kg |
| Data Storage | 19,999 measurement records |
| Communication Options | Optional RS-485 interface (customizable for continuous online monitoring), optional Bluetooth printer support |