Rheometer/Viscometer
Filter
Showing 181–207 of 207 results
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable |
| Measurement Principle | Falling-Pin Viscometry |
| Viscosity Range | 5–10⁶ cP |
| Sample Volume | 4.5 mL |
| Accuracy | ±3% (PDV-100) |
| Repeatability | ±3% |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D7483, ISO 12058-1 (for falling-body viscometry), GLP-ready workflow support |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Model | NXS-11B |
| Viscosity Range | 2.8–1.78×10⁷ mPa·s |
| Shear Stress Range | 27.67–21,970 Pa |
| Shear Rate Range | 1.23–996 s⁻¹ |
| Speed Range | 5.6–360 rpm |
| Repeatability | ±1% FS (Newtonian fluids) |
| Construction | Stainless steel coaxial cylinder system |
| Instrument Type | Coaxial Cylinder Rotational Viscometer |
| Portability | Benchtop and handheld operation capable |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary Flow (Ubbelohde & Ostwald-type) |
| Time Range | 0.01–9999.99 s (resolution: 0.01 s) |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (positive pressure mode) / 0.35–5000 mm²/s (vacuum mode) |
| Timer Accuracy | ±0.01% |
| Temperature Equilibration Time Setting | 0–20 min (in 1-min increments) |
| Replicate Runs | 1–10 per sample |
| Interface | RS-232C |
| Power Supply | 115/230 VAC, 50/60 Hz, 30 W |
| Housing | Anodized aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVS370 |
| Measurement Principle | Capillary efflux time (kinematic viscosity) via photometric and thermal-conductivity detection |
| Pressure Modes | Positive pressure & vacuum aspiration |
| Timer Resolution | 0.01 s |
| Time Range | 0.01–9999.99 s |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under positive pressure |
| Timer Accuracy | ±0.01% |
| Pump Control | Microprocessor-regulated ViscoPump II (up to 4 units per chassis) |
| Temperature Equilibration Delay | 0–20 min (user-configurable) |
| Replicates per Sample | 1–10 |
| Interface | RS-232C |
| Power | 115/230 VAC, 50/60 Hz, 30 W |
| Enclosure | Powder-coated aluminum |
| Dimensions (W×H×D) | 225 × 205 × 320 mm |
| Weight | 5.4 kg |
| Compatible Viscometers | DIN Ubbelohde, ASTM Ubbelohde, DIN Micro Ubbelohde, Micro Ostwald, Cannon-Fenske Routine, TC-Ubbelohde, TC-Micro Ubbelohde |
| Brand | SCHOTT |
|---|---|
| Origin | Germany |
| Model | AVSPro |
| Measurement Principle | Capillary Flow (ASTM D445, ISO 3104, IP 71) |
| Kinematic Viscosity Range | 0.35–1200 mm²/s at ambient temperature |
| Accuracy | ±0.01% of reading + ±1 digit |
| Replicate Runs | 1–99 per sample |
| Temperature Equilibration Time | 0–99 min |
| Detection Methods | Dual-mode — Opto-electronic (for transparent/clear liquids) and Thermal Conductivity (TC) sensing (for opaque, dark, or highly viscous samples) |
| Sample Handling | Fully automated liquid handling with programmable injection sequence |
| Interface | RS-232/USB for PC integration |
| Compliance | Designed to meet ASTM D445, ISO 3104, ISO 17025 requirements for accredited viscosity testing laboratories |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CFT-EX Series |
| Instrument Type | Capillary Rheometer |
| Temperature Range | 20–400 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Displacement Range | 15 mm |
| Displacement Resolution | 0.01 mm |
| Sample Volume | Up to 1.5 cm³ |
| Viscosity Measurement Range | 1×10¹–1×10⁶ Pa·s (CFT-500EX) |
| Heating Method | Resistive Wire Heating |
| Loading Method | Dead-Weight Piston Drive |
| Test Modes | Isothermal and Temperature-Ramp (Rheological Softening Point) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Model | SMV-301 / SMV-301RT |
| Compliance Standards | JIS K6300, ISO 289, ASTM D1646, BS 1673 |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Rotational Speed Range (SMV-301RT) | 0.5–5 rpm |
| Mooney Viscosity Range | 0–200 M (optional 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Rotor Type | L-shaped |
| Curing Point Setting Range | 0–99.9 M (up to 10 points) |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points) |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | RSX-CC |
| Pricing | Available Upon Request |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Model | NDJ-1 / NDJ-4 |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Rotational Viscometer |
| Model | SNB-3 / SNB-4 (Color Touchscreen) |
| Viscosity Range | 1–2,000,000 mPa·s |
| Control System | MCS-51 Microcontroller-Based Stepper Motor Drive |
| Display | Full-Color TFT Touchscreen Interface |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | SNB-E Portable Digital Rotational Viscometer |
| Pricing | Available Upon Request |
| Display | Large Backlit LCD (Dual-Language: English/Chinese) |
| Temperature Range | –50 °C to 99 °C (with optional semiconductor temperature probe) |
| Viscosity Range | 0.1–6×10⁶ mPa·s (with standard and optional “0” spindle) |
| Interface | RS232 serial port |
| Power Supply | External AC adapter |
| Compliance | GLP/GMP-ready with real-time clock and audit-trail-capable data logging |
| Brand | Techne |
|---|---|
| Origin | United Kingdom |
| Model | GT-5 / GT-6 |
| Category | Rheometer/Viscometer Peripheral Service Offering |
| Compliance | ASTM D4287, ISO 1133-2 (gelation timing reference), USP <724> (for hydrogel formation kinetics) |
| Service Scope | Calibration, Repair, Legacy Unit Support |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Model | HAAKE Falling Ball |
| Instrument Type | Falling Ball Viscometer |
| Viscosity Range | 0.5 – 100,000 mPa·s |
| Temperature Range | −1 °C to +26 °C |
| Repeatability | < 0.5 % |
| Reproducibility | < 1 % |
| Measurement Tube Material | Borosilicate Glass (Tubes 1, 2, G) |
| Ball Materials | Nickel–Iron Alloy (Balls 3, 4, 5, 6) |
| Compliance | DIN 53015, ISO 120587 |
| Optional Accessories | Digital Stopwatch, Ball G (for gas viscosity), PT100 Temperature Sensor for HAAKE D50 Circulator |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Rotational Viscometer |
| Model | VT C / VT D / VT E |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Accuracy | ±1 % FSD |
| Repeatability | 0.2 % FSD |
| Speed Range | 0.01 – 200 rpm |
| Compliance | ISO 2555, ASTM D1084/D2196/D2556/D2983/D3232, BS 6075/5350 |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Viscometer |
| Model | HAAKE Viscotester D |
| Viscosity Range | 15 – 40,000,000 mPa·s |
| Compliance | ISO 2555 |
| Rotor Geometry | Standard Spindle (e.g., LV, RV, HA, HB series) |
| Shear Rate Range | Dependent on spindle geometry and rotational speed (typically 0.1–1000 s⁻¹) |
| Accuracy | ±1% of full scale (per ISO 2555 calibration requirements) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Origin Category | Imported |
| Model | VT550 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 2 – 10⁷ mPa·s |
| Speed Range | 0.5 – 800 rpm |
| Torque Range | 0.1 – 50 mN·m (up to 400 rpm), 0.1 – 20 mN·m (up to 800 rpm) |
| Temperature Range | −40 °C to +350 °C (dependent on optional temperature control unit) |
| Compliance Standards | ISO 2555, ISO 3219, DIN 53018, DIN 53019 |
| Control Mode | Preset Programs (10 built-in), Controlled Deformation (CD) mode for yield stress determination |
| Software Integration | RheoWin (HAAKE proprietary software) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | MARS iQ |
| Instrument Category | Rotational Rheometer |
| Bearing Type | Mechanical Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Frequency Range | 0.01–20 Hz |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 2.0 µN·m |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer Coupling Module |
| Model | Rheonaut |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1 × 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| ATR Crystal Material | Diamond (Single-Reflection) |
| Temperature Control Options | Peltier (0–120 °C) or Electric Heating (RT–400 °C) |
| Detector | DTGS |
| Polarization Options | Manual/Automatic Dual-Axis Polarizers |
| Compliance | ASTM D3835, ISO 6721-10, USP <1043>, GLP/GMP-ready data audit trail support |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | Tokisangyo Co., Ltd. |
| Type | Fixed-Mount Viscometer |
| Operating Environment | Ambient Temperature |
| Compatible Rotors | TH Series (for TVB-10HW/10RW/10UW/15H/15R/15U/25H/35H), TM Series (for TVB-10MW/15M/25/35L) |
| Sample Adapters | THM (low-volume, for TM-series rotors), THH (low-volume, for TH-series rotors), Low-Viscosity Adapter (for TM-series rotors) |
| Standard Axis Stand | TS-20 (compatible with TVB-10/15/25/35 models) |
| Measuring Range | 15–67.4 mPa·s |
| Maximum Torque | 15 μN·m |
| Instrument Category | Specialty Rotational Viscometer |
| Compliance | Designed per JIS Z 8803 and ISO 2555 for solution viscosity measurement |
| Brand | TQC |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sheen Efflux Cup |
| Pricing | Upon Request |
| Brand | Xiatech |
|---|---|
| Origin | Shaanxi, China |
| Model | VM4300 |
| Viscosity Range | ≤200 µPa·s |
| Temperature Range | 14–300 K |
| Pressure Range | 0.1–4 MPa |
| Accuracy | ±3% |
| Measurement Principle | Vibrating Wire Method |
| Interface | USB |
| Operating System | Windows |
| Power Supply | 220 V, 50 Hz |
| Brand | Zhonghang Shidai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Torque Rheometer |
| Model | TR-200A |
| Motor Power | 3.0 kW (Panasonic servo motor & drive) |
| Speed Range | 0.1–120 rpm (max mechanical speed: 2000 rpm) |
| Torque Range | 0–200 N·m (rated: 300 N·m) |
| Torque Resolution | < 100 nN·m |
| Torque Accuracy | ±0.3% F.S. |
| Temperature Control Range | Ambient to 350 °C (5-zone heating) |
| Temp. Control Accuracy | ±0.5 °C |
| Pressure Measurement Range | 0.1–100 MPa (optional, configurable) |
| Pressure Accuracy | ±0.3% F.S. |
| Data Acquisition Rate | 50 Hz |
| Heating Method | Electric (cartridge heaters) |
| Rotor Types | Roller (standard), Banbury/Cam/Delta (optional) |
| Mixer Volume | 60 mL (standard), 200 mL (optional) |
| Extruder | Single-screw, L/D = 25:1, Ø20 mm, 5-zone heating, max temp 350 °C |
| Compliance | Designed for ASTM D3835, ISO 6721-10, and USP <911> rheological simulation workflows |
| Software | Integrated Mixer, Plastic, and WinNian modules with GLP-compliant audit trail, curve overlay, real-time derivative analysis, and capillary rheometry correction algorithms |
| Brand | ZVISCO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | IV6600 |
| Instrument Type | Capillary Viscometer |
| Viscosity Range | 0.3–5000 mm²/s |
| Temperature Control Range | 15–65 °C |
| Temperature Uniformity & Stability | ≤ ±0.01 °C |
| Timing Resolution | 0.0001 s |
| Measuring Time Range | 0.01–9999.99 s |
| Cleaning/Drying Fluid Consumption per Cycle | < 13 mL |
| Compatible Capillaries | Ubbelohde, Micro-Ubbelohde, Dilution-type Ubbelohde (compliant with ISO 3105, GB/T 1632–1993, ASTM D 446, DIN 51562) |
| Software Platform | Windows XP/7/8/10 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 1.9 kW |
| Dimensions (L×W×H) | 1300 × 600 × 600 mm |