| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSX-CC |
| Pricing | Available Upon Request |
| Brand | Cannon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TE-BBR |
| Instrument Type | Bending Beam Rheometer |
| Bearing Type | Air-bearing |
| Minimum Oscillation Frequency | 0.1 Hz |
| Frequency Range | 0.1–100 Hz |
| Maximum Oscillation Frequency | 100 Hz |
| Maximum Applied Load | 45 g (0.441 N) |
| Load Resolution | 0.015 g (0.147 mN) |
| Displacement Resolution | 0.155 µm |
| Temperature Control Stability | ±0.03 °C |
| Minimum Operating Temperature | –36 °C |
| Cooling Method | Thermoelectric (Peltier) with Air/Water Heat Exchange |
| Interface | RS-232 Serial |
| Software Platform | Windows 95/NT (v3.51 or later) |
| System Requirements | IBM-compatible PC, SVGA monitor, 16 MB RAM, 20 MB free HDD space, 1.44 MB floppy drive |
| Brand | Formulaction (Microtrac) |
|---|---|
| Origin | France |
| Model | Rheolaser Master |
| Instrument Type | Optical Microrheometer |
| Sample State | Liquid |
| Measurement Principle | Multi-Speckle Diffusing Wave Spectroscopy (MS-DWS) |
| Temperature Range | +5°C above ambient to 90°C (optional up to 150°C) |
| Frequency Range | 10⁻⁴ Hz to 10² Hz |
| RMS Particle Displacement Range | 0.1 nm – 100 nm |
| Minimum Detectable Particle Size | 50 nm |
| Maximum Solid Volume Concentration | 90% v/v |
| Torque Specifications | Not applicable (non-mechanical, optical measurement) |
| Data Acquisition | High-resolution CMOS camera-based speckle image analysis |
| Sample Holder | 20 mL borosilicate glass cuvette with 6-position sample carousel |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | CaBER 1 |
| Motor Type | Linear Motor |
| Hencky Strain (ε₀) | 10 |
| Applied Strain Rate Range | 0.01–300 s⁻¹ |
| Fluid Strain Rate Range | 10⁻⁵–10 s⁻¹ |
| Shear Viscosity Range | 10–10⁶ mPa·s |
| Plate Diameter | 4–8 mm (standard: 6 mm) |
| Temperature Range | 0–80 °C |
| Filament Diameter Resolution | 10 µm |
| System Response Time | 10 ms |
| Dimensions | 40 × 34 × 60 cm |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | Mars 40 |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air-bearing (2 radial + 1 axial) |
| Minimum Rotational Speed | 1×10⁻⁷ rpm |
| Maximum Rotational Speed | 4500 rpm |
| Frequency Range | 1×10⁻⁶ – 100 rad/s |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Motor Inertia | 1×10⁻⁵ kg·m² |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | MARS III |
| Minimum Torque | 0.003 µN·m |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 10 µN·m·s² |
| Minimum Rotational Speed | 1.0×10⁻⁸ rpm |
| Maximum Rotational Speed | 1500 rpm (4500 rpm optional) |
| Minimum Oscillation Frequency | 1.0×10⁻⁶ Hz |
| Maximum Oscillation Frequency | 100 Hz |
| Normal Force Range | 0.01–50 N |
| Normal Force Resolution | 0.001 N |
| Temperature Control Range (Peltier) | −60 to 200 °C |
| Temperature Control Range (Electric Heater) | 30 to 300 °C |
| Temperature Control Range (Liquid Circulator) | −40 to 180 °C |
| Temperature Control Range (CTC Radiation/Convection Furnace) | −150 to 600 °C |
| Bidirectional Normal Force Measurement | Yes |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | MiniLab II |
| Instrument Type | Torque Rheometer |
| Screw Configuration | Co-rotating and Counter-rotating Conical Twin-Screw |
| Minimum Speed | 1 rpm |
| Maximum Speed | 360 rpm |
| Frequency Range | 0.1–37.7 rad/s |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Motor Power | 400 W |
| Barrel Volume | 7 cm³ (≈5 g PE) |
| Max Temperature | 350 °C (optional 420 °C) |
| Max Pressure | 200 bar |
| Barrel Material | Stainless Steel (HRC55) |
| Screw Material | Stainless Steel 1.4122 |
| Cooling | Air/Water (350 °C version), Air-only (420 °C version) |
| Flow Path | Integrated Recirculation Channel with Automated Bypass Valve |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Laboratory-Scale Co-Rotating Twin-Screw Extruder |
| Screw Diameter | 11 mm |
| L/D Ratio | 40:1 |
| Drive Power | 1.25 kW |
| Speed Range | 10–1000 rpm (infinitely variable) |
| Max Operating Pressure | 100 bar (with integrated safety monitoring) |
| Temperature Range | Ambient to 350 °C (optional up to 450 °C) |
| Barrel Zones | 8 (1 cooling feed zone + 7 independently heated zones) |
| Footprint | 82 × 48 × 34 cm (L × W × H) |
| Throughput | Up to 2.5 kg/h |
| Minimum Sample Requirement | ~20 g |
| Screw Design | Modular, segmentable for customizable configuration |
| Barrel Configuration | Horizontally split, top barrel section removable |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Benchtop Controlled-Stress/Controlled-Rate Rotational Rheometer |
| Model | RS 1 |
| Drive System | Air-bearing motor |
| Minimum Rotational Speed | 1.0 × 10⁻³ rpm |
| Maximum Rotational Speed | 1200 rpm |
| Angular Frequency Range (Oscillatory Mode) | 1.0 × 10⁻⁴ – 100 rad/s |
| Maximum Torque | 100 mN·m |
| Torque Resolution | 5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Motor Inertia | 11 µN·m·s² |
| Normal Force Range | Not specified |
| Normal Force Resolution | Not specified |
| Temperature Control Options | Peltier (–40 to +180 °C), Electric Heating (+20 to +200 °C), Liquid Circulator (–40 to +180 °C) |
| Optional Accessories | Star Geometry, SHRP Asphalt Testing System, Anti-Slip System |
| Brand | HAAKE |
|---|---|
| Origin | Germany |
| Model | RS6000 |
| Motor Technology | 4th-generation vector-controlled motor |
| Torque Range | 0.005 µN·m (min) to 200 mN·m (max) |
| Torque Resolution | 0.5 nN·m |
| Angular Displacement Resolution | 0.012 µrad |
| Rotational Speed Range | 1.0×10⁻⁷ – 1500 rpm (up to 4500 rpm optional) |
| Oscillation Frequency Range | 1.0×10⁻⁵ – 100 Hz |
| Normal Force Range | ±0.01–50 N |
| Normal Force Resolution | 0.001 N |
| Temperature Control | Peltier (−60 to 200 °C), Electric Heater (30 to 300 °C), Liquid Circulator (−40 to 180 °C) |
| Data Acquisition Rate | 2.5 ms per point |
| Compliance | ASTM D4402, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11-ready software architecture |
| Origin | USA |
|---|---|
| Manufacturer | Kaltec (USA) |
| Instrument Type | Rotational Rheometer |
| Max Shear Rate | 1–1.38×10⁵ s⁻¹ (standard), up to 1.85×10⁵ s⁻¹ (upgraded) |
| Torque Range | 1.0×10⁴–1.8×10⁷ dyn·cm |
| Shear Stress Range | 80–6.0×10⁵ dyn/cm² |
| Recommended Viscosity Range | 1–4.5×10³ cP (10⁻² P) |
| Weight | 62 kg |
| Dimensions (H×W×D) | 81×64×46 cm |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | DWS RheoLab |
| Temperature Range | 5°C–100°C |
| Frequency Range | 0.1 Hz–10 MHz |
| Minimum Measurable Frequency | 0.1 Hz |
| Maximum Measurable Frequency | 10⁷ Hz |
| Sample Volume Requirement | ≥150 µL |
| Sample State | Liquid |
| Measurement Principle | Diffusing Wave Spectroscopy (DWS) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | LS Instruments RheoSoft v5.x |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 325 rad/s |
| Frequency Range | 1 µHz – 100 Hz |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Rate/Stress Control) | 0.01 µNm – 200 mNm |
| Torque Range (Strain/Stress Control) | 0.05 µNm – 200 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR-III |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 200 rad/s |
| Frequency Range | 1 µHz – 100 Hz |
| Maximum Torque | 150 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.01 N – 20 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 20 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Rate/Stress Control) | 0.1 µNm – 150 mNm |
| Torque Range (Strain/Stress Control) | 0.1 µNm – 150 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR+ |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Minimum Angular Velocity | 1 nrad/s |
| Maximum Angular Velocity | 500 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 225 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Control Modes | Rate, Stress, Strain |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus lab+ |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 325 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | 10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Steady-State) | 0.01 µNm – 200 mNm |
| Torque Range (Oscillatory) | 0.005 µNm – 200 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Prime Ultra+ |
| Instrument Type | Rotational Rheometer |
| Frequency Range | 1 µHz to 150 Hz |
| Temperature Control | Modular EasySwap™ Environmental Units |
| Normal Force Control | High-Sensitivity Electromagnetic Sensor |
| Vertical Travel & Gap Control | Precision Motorized Actuation |
| Compliance | ASTM D3835, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11 (Software Mode), GLP/GMP Audit Trail Capable |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus pro+ |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 1 nrad/s |
| Maximum Angular Velocity | 500 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 225 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Steady-State) | 0.005 µNm – 225 mNm |
| Torque Range (Oscillatory) | 0.001 µNm – 225 mNm |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Rosand RH10 |
| Instrument Type | Capillary Rheometer |
| Sample State | Liquid |
| Minimum Extrusion Speed | 5 µm/min |
| Maximum Extrusion Speed | 1200 mm/min |
| Maximum Load | 100 kN |
| Die Diameter Range | 0.5–3 mm |
| Barrel Diameter (Standard) | 15 mm (Optional: 9.5, 12, 19, 24 mm) |
| Barrel Material | Nitrided Steel (Optional: Stainless Steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Speed Dynamic Range | 240,000:1 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Rosand RH2000 |
| Instrument Type | Capillary Rheometer |
| Sample State | Liquid |
| Minimum Piston Speed | 10 µm/min |
| Maximum Piston Speed | 1200 mm/min |
| Maximum Load | 20 kN |
| Die Diameter Range | 0.5–3 mm |
| Barrel Diameter | 15 mm (standard), optional 9.5 / 12 / 19 / 24 mm |
| Barrel Material | Nitrided Steel (optional stainless steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Speed Dynamic Range | 240,000:1 |
| Compliance | ASTM D3835, ISO 11443, ISO 6721-6, USP <911> |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | Kinexus Rosand RH7 |
| Instrument Type | Capillary Rheometer |
| Minimum Extrusion Speed | 2.5 µm/min |
| Maximum Extrusion Speed | 600 mm/min |
| Maximum Load Capacity | 50 kN |
| Speed Dynamic Range | 240,000:1 |
| Standard Barrel Diameter | 15 mm (optional: 9.5, 12, 19, 24 mm) |
| Barrel Material | Nitrided Steel (optional: Stainless Steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Die Diameter Range | 0.5–3 mm |
| Optional Accessories | Nitrogen Purge System, Melt Strength Tester, Melt Draw-Down Fixture, Laser-Based Die Swell Measurement, Slit Dies, PVT Measurement Dies, Melt Cut-Off Knife |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CFT-EX Series |
| Instrument Type | Capillary Rheometer |
| Temperature Range | 20–400 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Displacement Range | 15 mm |
| Displacement Resolution | 0.01 mm |
| Sample Volume | Up to 1.5 cm³ |
| Viscosity Measurement Range | 1×10¹–1×10⁶ Pa·s (CFT-500EX) |
| Heating Method | Resistive Wire Heating |
| Loading Method | Dead-Weight Piston Drive |
| Test Modes | Isothermal and Temperature-Ramp (Rheological Softening Point) |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | RSX-CC |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1×10⁻⁸ rpm |
| Frequency Range | 1×10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Angular Displacement Resolution | 12 nrad |
| Normal Force Range | 0.01 – 50 N |
| Normal Force Resolution | 0.001 N |
| Vertical Travel | 240 mm |
| Gap Resolution | 0.5 µm |
| Minimum Vertical Speed | 0.02 µm/s |
| Maximum Vertical Speed | 20 mm/s |
| Temperature Range (with optional modules) | −150 °C to +600 °C |
| Dimensions (W×D×H) | 600 × 600 × 890 mm |
| Weight | 59 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Torque Rheometer |
| Model | PolyLab OS |
| Motor Bearing | Screw-driven |
| Minimum Speed | 1 rpm |
| Frequency Range | 0.1–115 rad/s |
| Maximum Speed | 250 rpm (up to 1100 rpm optional) |
| Maximum Torque | 120 mNm (dual-range: 120/400 Nm) |
| Torque Resolution | 0.01 / 0.1 Nm |
| Temperature Range | Up to 400 °C (optional 450–500 °C) |
| Heating/Cooling | Electric heating + compressed air cooling |
| Control Zones | 7–10 independent temperature zones |
| Pressure Capability | Up to 700 bar |
| Barrel Design | Modular, horizontally split |
| Screw Configurations | Single-screw (Ø19.05 mm), Conical counter-rotating twin-screw (Ø31.8/20 mm), Parallel co-rotating twin-screw (Ø16/24 mm), Banbury-type mixer (120/625 cm³ chamber volume) |
| Power Supply | 7 kW / 16 kW |
| L/D Ratios | 10:1, 25:1, 33:1 (single-screw) |
| 25 | 1 to 40:1 (twin-screw) |
| Extrusion Capacity | ~5 kg/h (polymer-dependent) |
| Compliance | DIN 1.4301 stainless steel (mixer), DIN 1.8550 nitrided steel (screws/barrels) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PolyLab QC |
| Instrument Category | Torque Rheometer |
| Drive Bearing | Single-screw configuration |
| Minimum Speed | 1 rpm |
| Frequency Range | 1–21 rad/s |
| Maximum Speed | 200 rpm |
| Maximum Torque | 300 N·m |
| Torque Resolution | 0.1 N·m |
| Torque Accuracy | ±0.15% of full scale |
| Temperature Range | Up to 450 °C (heating via electric cartridge heaters |
| Screw Material | Nitrided stainless steel (DIN 1.8550) |
| Chamber Material | Stainless steel (DIN 1.4301) |
| Mixer Chamber Volume | 120 cm³ or 625 cm³ |
| Screw Diameter | 19.05 mm (single-screw unit) / 31.8 mm & 20 mm (conical counter-rotating twin-screw unit) |
| Screw L/D Ratio | 25 |
| Screw Length | 300 mm |
| Gear Ratio | 3:2 |
| Maximum System Pressure | 700 bar |
| Power Rating | 4 kW |
| Control Interface | USB or optional Ethernet (LAN) |
| Software Platform | HAAKE PolySoft v7.x (Windows-based) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer |
| Motor Bearing | Air-bearing-free (direct-drive torque sensor) |
| Minimum Angular Velocity | 0.001 rad/s |
| Maximum Angular Velocity | 157 rad/s (≈1500 rpm) |
| Torque Range | 0.2–100 mN·m |
| Torque Resolution | 0.002 mN·m (0.2% of full scale) |
| Oscillation Frequency Range | 0.01–100 Hz (with optional oscillatory module) |
| Temperature Control | Peltier-based, -10 to +130 °C (with coaxial cylinder or cone/plate geometry) |
| Geometry Auto-Recognition | Yes |
| Interface | 7″ capacitive touchscreen + USB host/device + Ethernet |
| Software | HAAKE RheoApp (standalone on USB drive) and HAAKE RheoWin (PC-based, GLP-compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | MARS iQ |
| Instrument Category | Rotational Rheometer |
| Bearing Type | Mechanical Ball Bearing |
| Minimum Rotational Speed | 0.01 rpm |
| Maximum Rotational Speed | 2000 rpm |
| Frequency Range | 0.01–20 Hz |
| Maximum Torque | 125 mN·m |
| Torque Resolution | 2.0 µN·m |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Rotational Rheometer Coupling Module |
| Model | Rheonaut |
| Motor Bearing | Air Bearing |
| Minimum Rotational Speed | 1 × 10⁻⁸ rpm |
| Frequency Range | 10⁻⁶ – 100 Hz |
| Maximum Rotational Speed | 4500 rpm |
| Maximum Torque | 200 mN·m |
| Torque Resolution | 0.1 nN·m |
| ATR Crystal Material | Diamond (Single-Reflection) |
| Temperature Control Options | Peltier (0–120 °C) or Electric Heating (RT–400 °C) |
| Detector | DTGS |
| Polarization Options | Manual/Automatic Dual-Axis Polarizers |
| Compliance | ASTM D3835, ISO 6721-10, USP <1043>, GLP/GMP-ready data audit trail support |
| Brand | Zhonghang Shidai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Torque Rheometer |
| Model | TR-200A |
| Motor Power | 3.0 kW (Panasonic servo motor & drive) |
| Speed Range | 0.1–120 rpm (max mechanical speed: 2000 rpm) |
| Torque Range | 0–200 N·m (rated: 300 N·m) |
| Torque Resolution | < 100 nN·m |
| Torque Accuracy | ±0.3% F.S. |
| Temperature Control Range | Ambient to 350 °C (5-zone heating) |
| Temp. Control Accuracy | ±0.5 °C |
| Pressure Measurement Range | 0.1–100 MPa (optional, configurable) |
| Pressure Accuracy | ±0.3% F.S. |
| Data Acquisition Rate | 50 Hz |
| Heating Method | Electric (cartridge heaters) |
| Rotor Types | Roller (standard), Banbury/Cam/Delta (optional) |
| Mixer Volume | 60 mL (standard), 200 mL (optional) |
| Extruder | Single-screw, L/D = 25:1, Ø20 mm, 5-zone heating, max temp 350 °C |
| Compliance | Designed for ASTM D3835, ISO 6721-10, and USP <911> rheological simulation workflows |
| Software | Integrated Mixer, Plastic, and WinNian modules with GLP-compliant audit trail, curve overlay, real-time derivative analysis, and capillary rheometry correction algorithms |