Rubber & Plastic Industry Specialized Instruments
Filter
Showing 1–30 of 171 results
| Brand | Aboni |
|---|---|
| Origin | Germany |
| Model | HT3 |
| Measurement Principle | Calcium Hydride Reaction (Hydrogen Gas Evolution) |
| Sample Capacity | 0.01–50 g (up to 100 g depending on density & moisture content) |
| Sample Volume | ~50 mL |
| Detection Range | 0.2–30 mg H₂O |
| Resolution | ±0.1 mg H₂O (at 1 mg) to ±0.3 mg H₂O (at 20 mg) |
| Heating Temperature Range | 50–210 °C (1 °C increments) |
| Reagent | Calcium Hydride (CaH₂) powder, ~0.1 g per test |
| Environmental Monitoring | Temperature (±0.1 °C), Relative Humidity (0–100 % RH, ±0.1 %), Atmospheric Pressure (700–1100 mbar, ±0.1 mbar) |
| Power Supply | 230 VAC, 1.6 A |
| Dimensions | 285 (H) × 170 (W) × 250 (D) mm |
| Weight | 4.6 kg |
| Interface | RS232 or USB |
| Compliance | ISO 15512 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CTI-3 |
| Voltage Range | 100–600 V (25 V steps) |
| Electrode Material | Tungsten (99% purity) / Copper electrode holder |
| Electrode Dimensions | (2.0 ± 0.1) mm × (5.0 ± 0.1) mm × (40 ± 5) mm |
| Platinum Electrode Tip | 12 mm, 30° ± 2° bevel |
| Electrode Spacing | 4.00 ± 0.01 mm, 60° ± 5° included angle |
| Electrode Force | 1.00 ± 0.01 N |
| Test Solution Resistivity | Solution A: 3.95 ± 0.05 Ω·m (0.1% NH₄Cl) |
| Solution B | 1.98 ± 0.05 Ω·m |
| Drop Height | 35 ± 5 mm (adjustable) |
| Drop Interval | 30.00 ± 0.01 s (pre-settable) |
| Drops per cm³ | 44–55 |
| Total Drops Programmable | 1–9999 |
| Airflow Velocity | 0.2 m/s |
| Short-Circuit Current | 1.000 ± 0.001 A (voltage drop ≤ 8% at 1.0 A) |
| Tracking Threshold | 0.50 ± 0.05 A for ≥ 2.0 ± 0.2 s |
| Chamber Volume | > 0.5 m³ |
| Ambient Conditions | 0–40 °C, RH ≤ 80%, non-corrosive, vibration-free environment |
| Power Supply | 220 V AC, 0.6 kVA, 50–60 Hz |
| Dimensions (W×D×H) | 1160 × 600 × 1310 mm |
| Weight | Approx. 125 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | GB/T 1692 Resistivity Tester |
| Compliance | GB/T 1692–2008, GB/T 1410, ASTM D257, IEC 60093 |
| Measurement Range | 1 × 10⁶ Ω to 1 × 10¹⁶ Ω |
| Test Voltages | 100 V, 250 V, 500 V, 1000 V (DC) |
| Electrode Configuration | Three-electrode system (main electrode Ø50 mm, guard ring ≥10 mm wide, grounded outer electrode) |
| Accuracy | ±20% of reading |
| Environmental Control Support | Compatible with standard climatic chambers (23 ± 2 °C / 50 ± 5 %RH) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | HDT-VST-300E |
| Temperature Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Heating Medium | Methyl Silicone Oil (up to 300 °C) or Transformer Oil (up to 200 °C) |
| Standard Config | 3 Test Stations |
| Load Application | Mechanical Deadweight via Precision Calibration Weights |
| Temperature Sensing | PT100 Platinum Resistance Thermometer |
| Deformation Sensing | High-Resolution Digital Micrometer Sensor (0–10 mm range, 0.001 mm resolution) |
| Control System | 32-bit ARM Embedded Processor with Real-Time Isothermal Ramp Algorithm |
| Compliance | ISO 75-1:1993, ISO 306:1994, GB/T 1633–2000, GB/T 1634–2001 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | LDQ-5 |
| Voltage Range | 50–600 V AC/DC (±1% step accuracy) |
| Electrolyte | NH₄Cl solution (0.1–1.0 wt%), flow rate 0.5–2.0 mL/min (programmable) |
| Electrode Material | Pt-Rh alloy |
| Electrode Angle | 60° ± 5° |
| Electrode Force | 1.0 N ± 0.05 N |
| Trip Current Threshold | 0.5 A ± 10%, arc duration ≥ 2 s |
| Temperature Sensor Accuracy | ±1 °C |
| Humidity Range | 20–80 %RH |
| Data Acquisition | 16-bit resolution, current resolution 0.1 mA |
| Compliance | IEC 60112:2020, ASTM D3638-21, UL 746A, GB/T 4207-2022, VDE 0303-11, IEC 60695-2-2 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VFTA-2 |
| Price Range | USD 3,600 – 7,200 |
| Dimensions (W×D×H) | 1160 × 600 × 1250 mm |
| Combustion Chamber Volume | >0.5 m³ |
| Background | Matte Black, Illuminance ≤20 lux |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Rated Power | 150 W |
| Fuel Gas | Industrial propane, butane, or propane-butane mixture |
| Ignition Timer Range | 0–999.9 s |
| Burn Time Measurement Range | 0–999.9 s |
| Timing Resolution | 0.1 s |
| Flame Positioner Distances | 17 ±1 mm and 20 ±1 mm |
| Flame Height Calibration | 40 ±2 mm (vertical), 25 ±2 mm (horizontal) |
| Combustion Chamber Internal Dimensions | 900 × 600 × 1000 mm |
| Approx. Weight | 80 kg |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-121 |
| Measurement Principle | Four-Terminal (Kelvin) Method with Guarded Electrode System |
| Voltage Range | 10 V – 1000 V (selectable in discrete steps) |
| Resistance Range | 10³ Ω·cm to 10¹⁸ Ω·cm |
| Current Resolution | 0.1 fA |
| Compliance Standards | ASTM D257, IEC 60093, GB/T 1410 |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <80% RH (non-condensing) |
| Interface | RS485, USB |
| Safety Features | Overload protection, short-circuit protection, galvanic isolation, shielded enclosure (<5 µV residual noise) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ZST-121 |
| Price Range | USD 2,100 – 7,000 |
| Resistance Range | 10 Ω to 2×10¹⁷ Ω |
| Resistance Accuracy | ±1% |
| Voltage Settings | 100 V, 250 V, 500 V, 1000 V |
| Voltage Accuracy | ±2% |
| Current Measurement Range | — |
| Display | 3½-digit LCD with backlight |
| Built-in Timer | 1–7 min auto-hold |
| Power Supply | 8×AA batteries (DC 8.5–12.5 V) or external regulated DC source |
| Dimensions (L×W×H) | 280 × 240 × 105 mm |
| Weight | 3 kg |
| Operating Environment | 0–40 °C, RH < 80% |
| Compliance | GB/T 1410–2006, GB/T 31838.1–2019, GB/T 2439–2001, GB/T 1692–2008, GB/T 10064–2006, GB/T 3048.5–2007 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZST-212 High-Resistance Meter |
| Price Range | USD 2,800 – 7,000 |
| Standards Compliance | IEC 60093, ASTM D257, GB/T 31838.2–2019, IEC 62631-3-1, GB/T 1410–2006, GB/T 1692–2008 |
| Display | 4.3-inch HD TFT |
| Voltage Range | ±10 V to ±1500 V DC (continuously adjustable) |
| Resistance Measurement Range | 10⁶ Ω to 10¹⁸ Ω (standard configuration) |
| Minimum Detectable Current | 10 fA |
| Input Impedance | >10¹⁶ Ω |
| Leakage Compensation | Dual-channel active current-voltage feedback network |
| Interface Options | USB 2.0, RS-232C, Handler (TTL/PLC-compatible) |
| Safety Features | ATEX-compliant explosion-proof variant available |
| Environmental Operating Range | −20 °C to +55 °C (industrial grade), relative humidity ≤75% RH (non-condensing) |
| Warm-up Time | ≥30 min required for metrological validity |
| Measurement Modes | Automatic & manual |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 |
| Measurement Range | 10⁶ Ω to 10¹⁸ Ω |
| Test Voltages | 10 V, 100 V, 250 V, 500 V, 1000 V DC |
| Input Impedance | >10¹⁴ Ω |
| Current Measurement Sensitivity | down to 1 fA |
| Compliance | IEC 60093, IEC 62631-3-1, ASTM D257, GB/T 1410 |
| Electrode Configuration | Tri-electrode system with guard ring |
| Environmental Operating Conditions | 23 ± 2 °C, 50 ± 5 % RH |
| Data Output | Digital LCD display with real-time current/resistance readout |
| Power Supply | AC mains with internal voltage regulation and EMI filtering |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-212 Volume & Surface Resistivity Tester |
| Test Voltage Range | 10 V – 1000 V DC (7 precision-adjustable steps, ±1% accuracy) |
| Volume Resistivity Range | 1×10⁴ Ω·cm to 1×10¹⁸ Ω·cm (15 auto-ranging decades, ±5% accuracy at 23°C ±2°C, 50% RH ±5%, 100 V) |
| Surface Resistivity Range | 1×10³ Ω to 1×10¹⁷ Ω (14 auto-ranging decades, ±6% accuracy under same conditions) |
| Minimum Detectable Current | 1×10⁻¹⁴ A |
| Input Impedance | >1×10¹⁴ Ω |
| Electrode System | Tri-electrode configuration (guard, measuring, high-voltage electrodes) |
| Compliance | GB/T 1410–2006, GB/T 31338–2015, ASTM D257–14, IEC 60093:2016, JJG 690–2015 (Class II) |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | ZST-530 |
| Volume Resistivity Range | 1.0×10⁴ to 1.0×10¹⁸ Ω·cm |
| Surface Resistivity Range | 1.0×10⁴ to 1.0×10¹⁷ Ω |
| Resolution (Volume) | 1.0×10³ Ω·cm |
| Resolution (Surface) | 1.0×10³ Ω |
| Accuracy | ±10% at 100 V |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Sample Thickness (Volume) | 0.01–30 mm |
| Sample Dimension (Surface) | ≥50 mm diameter or side length |
| Compliance | GB/T 1410-2006, ASTM D257-14 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BC-50KV |
| Output Voltage Range | AC/DC 0–50 kV |
| Rated Capacity | 5 kVA |
| Voltage Accuracy | ≤1% |
| Rise Rate Adjustment | 0.1–5.0 kV/s (continuously variable) |
| Test Modes | AC/DC stepwise ramp, constant-rate ramp, and hold-at-level withstand testing |
| Short-Circuit Response Time | ≤0.05 s |
| Leakage Current Measurement Range | 0–200 mA (real-time, mA-resolution) |
| Electrode Set per GB/T 1408.1–2006 | Two Φ25 mm × 25 mm |
| Test Mediums | Air or insulating oil |
| Compliance Standards | IEC 60243-1, ASTM D149, GB/T 1408.1–2006, UL 508, CSA C22.2 No. 0.3 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Volume Resistivity Range | 1.0×10³ Ω·m to 2.0×10¹² Ω·m |
| Surface Resistivity Range | 1.0×10⁴ Ω/□ to 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ Ω to 0.1×10¹² Ω (adjustable across 1–2 decades) |
| Power Supply | AC 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 mm × 90 mm × 275 mm |
| Net Weight | ≤3.0 kg |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Key | Brand: All Precision Instrument |
|---|---|
| Model | BQS-19 |
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Min Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7″ color touchscreen (256 colors), GUI in English/Chinese |
| Operating Environment | 0–50 °C, 10–80% RH |
| Data Storage | 32 GB internal (≥1 million test records) |
| Communication Interface | RS232/USB/Ethernet (with PC software for remote control & audit trail) |
| Compliance | Designed to support GMP, FDA 21 CFR Part 11, and ISO 13408-2 requirements |
| Test Modes | Bubble Point, Diffusion Flow, Water Intrusion |
| Typical Test Duration | Bubble Point (2 ± 2 min), Diffusion Flow (7 ± 2 min), Water Intrusion (7 ± 2 min), System Leak Check (3 ± 1 min) |
| Printing | Integrated thermal printer (bilingual report with test parameters, results, and real-time curve) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BRXZZ |
| Price | USD 3,500 (FOB Beijing) |
| Temperature Range | Ambient to 400 °C |
| Temperature Stability | ±0.1 °C |
| Temp. Recovery Time | < 4 min |
| Cut Count | 1–99 |
| Cut Interval | 10–600 s |
| Continuous Operation | >10,000 h |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Die Diameter | Φ2.095 ±0.005 mm |
| Die Length | 8.000 ±0.025 mm |
| Barrel ID | Φ9.550 ±0.025 mm |
| Barrel Length | 152.0 ±0.1 mm |
| Piston Head Diameter | 9.475 ±0.015 mm |
| Piston Head Length | 6.350 ±0.100 mm |
| Standard Loads (8 levels) | 0.325 kg (3.187 N) to 21.600 kg (211.82 N) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WYZ-240 |
| Price | USD 2,800 (FOB Beijing) |
| Max Cutting Width | 300 mm |
| Max Cutting Thickness | 15 mm |
| Max Milling Length (Flat/Dumbbell) | 300 mm |
| Cutting Wheel Dimensions | 200 × 32 × 2 mm |
| Notch Milling Tool Length | 50 mm |
| Dumbbell/Flat Milling Tool Dimensions | 30 × 12 × 30 mm |
| Overall Dimensions | 1130 × 720 × 950 mm |
| Spindle Speeds | Cutting Section: 1400–2800 rpm |
| Notch Milling Section | 400 rpm |
| Dumbbell/Flat Milling Section | Low-Speed: 470 / 940 rpm |
| High-Speed | 715 / 1430 rpm |
| Motor Power | Notch Milling Motor: 550 W |
| Dumbbell/Flat Milling Motor | 0.8–1.3 kW |
| Cutting Motor | 0.8 kW |
| Cooling Oil Pump Motor | 60 W |
| Auto-Feed Motor (Flat/Dumbbell) | 60 W |
| Brand | Alpha |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | disperGRADER |
| Price | Upon Request |
| Power Supply | 80–250 VAC, 47–63 Hz, 2 A |
| Dimensions (H×W×D) | 279.4 × 165.1 × 540 mm |
| Weight | 10.21 kg |
| Monitor | External (not included) |
| Computer Interface | Parallel port, IBM PC-compatible with Windows OS, min. display resolution 800×600 |
| Field of View (100×) | 4 mm × 3.5 mm |
| Field of View (30×) | 9 mm × 5 mm |
| Minimum Sample Size (100×) | 4.5 mm × 4 mm |
| Minimum Sample Size (30×) | 10 mm × 8 mm |
| Optional Accessories | External flatbed scanner, uncured sample cutter, uncured sample compression press |
| Brand | Alpha |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Premier MV |
| Pricing | Available Upon Request |
| Brand | Alpha |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Premier RPA |
| Pricing | Upon Request |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | D2020 |
| Measurement Principle | Hydrostatic Weighing (Air/Water Dual-Weight Method) |
| Density Range | 1.05–2.00 g/cm³ |
| Compliance | ISO 2781 |
| Temperature Compensation | Yes (liquid density correction vs. bath temperature) |
| Sample Throughput | 20-position automated carousel |
| Software Integration | Eclipse Daisy v5.x and Enterprise LIMS (barcode-enabled, specification limits, auto-reporting, audit-trail capable) |
| Pre-wetted carrier protocol | Yes |
| Readout Speed | <3 sec per sample post-stabilization |
| Regulatory Context | Supports GLP/GMP workflows with 21 CFR Part 11–compliant electronic records (when deployed with validated LIMS configuration) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | densiTECH+ |
| Measurement Principle | Hydrostatic Weighing (ASTM D297, ISO 2781, ASTM D792) |
| Sample Throughput | Up to 4 specimens/min |
| Density Accuracy | ±0.025% of reading |
| Mass Resolution | 0.0001 g |
| Applicable Materials | Cured rubber compounds, thermoplastic elastomers, carbon-black-filled polymers, vulcanizates |
| Compliance | ASTM D297–23, ISO 2781:2015, ISO 1183–1:2019, USP <841> (Density of Solids) |
| Brand | ALPHA (USA) |
|---|---|
| Origin | USA |
| Model | Premier MDR |
| Compliance | ASTM D5289, ISO 6520, DIN 53529 |
| Oscillation Frequency | 100 CPM (1.677 Hz) |
| Oscillation Amplitude | ±0.2°, ±0.5°, ±1.0°, ±3.0° (standard ±0.5°) |
| Temperature Range | 40–230 °C (100–446 °F) |
| Torque Range | 0.01–225 dN·m |
| Cavity Volume | ~1.43 cm³ (87.5 mm³ nominal |
| recommended sample volume | 1.84 cm³ / 112.5 mm³) |
| Pressure Channel | 0–8300 kPa (0–1200 psi) |
| Power Supply | 100–130 VAC ±10%, 60 ±3 Hz, 10 A or 200–260 VAC ±10%, 50 ±3 Hz, 5 A |
| Automation Options | 5-position manual test station or 16–144-position automated sample handling system |
| Software | Ultima Enterprise Pathfinder (Eclipse optional) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ALPHA CS-DFT Series |
| Price Range | USD 14,000 – 28,000 |
| Temperature Range | 23–120 °C |
| Frequency Range | 10–30 Hz |
| Static Load Capacity | 0–50 kg (0–110 lb) |
| Dynamic Stroke Range | 0–7.5 mm peak-to-peak |
| Specimen Dimensions | Ø17.8 mm × 25.4 mm (cylindrical) |
| Dimensions (H×W×D) | 122 cm × 76 cm × 61 cm |
| Weight | 250 kg (550 lb) |
| Power Supply | 110 VAC/60 Hz or 220 VAC/50 Hz, 20 A |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | tensiTech III |
| Compliance | ASTM D412, ASTM D575, ASTM D624 |
| Software | tensiDATA (data acquisition, control, analysis) |
| Actuation | Pneumatic grips |
| Extensometer | High-elongation digital extensometer |
| Programmability | Fully user-defined crosshead motion profiles and test sequences |
| Sample capacity | Up to 5 specimens per test run |
| Output units | Time, force, stress, strain (configurable) |
| Grip options | O-ring, wire wedge, curved jaw |
| Accessories | Digital thickness gauge, compression platens |
| Enclosure | Service-optimized chassis design |
| Application scope | Tensile, compression, tear, modulus measurement on elastomers and textiles |
| Target materials | Natural rubber, synthetic rubber, silicone rubber, thermoplastic elastomers (TPEs) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | tensiTech+ |
| Price Range | USD 14,000 – 28,000 |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Measurement Principle | Automated Titration-Based Oil Absorption (OAN) |
| Construction | Stainless Steel Housing |
| Software | Integrated PC-Based Control with Audit Trail & Data Export |
| Sample Handling | Dedicated Mixing Discs for Carbon Black & Silica |
| Viscosity Range | Up to 1,000,000 mPa·s |
| Solvent Compatibility | NMP, Paraffin Oil, and Other Standard Oils |
| Automation Level | Fully Automated Titration, Dosing, Mixing, Endpoint Detection |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | AbsorptoMeter |
| Standards Compliance | ASTM D2414, ASTM D3493, ASTM D6854 |
| Construction | Stainless steel housing |
| Automation | Software-controlled titration system |
| Titration Range | Adjustable dosing rate, suitable for viscosities up to 1,000,000 mPa·s |
| Solvent Compatibility | Compatible with aggressive solvents (e.g., NMP) |
| Data Management | Real-time result comparison, scheduled measurements, CSV/Excel export |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction under Vacuum |
| Compliance | DIN EN ISO 15512:2019 |
| Resolution | 0.0001% H₂O (w/w) |
| Application Scope | Polymer Residual Moisture Analysis & MFR Sample Conditioning |
| Software | Aquatrac Control Software with Audit Trail, LIMS/ERP Integration Capability |
| Regulatory Alignment | Supports GLP/GMP workflows and FDA 21 CFR Part 11–compliant data integrity requirements |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | TSSR |
| Application | Isothermal and Non-isothermal Stress Relaxation Testing (TSSR/AISR Method) |
| Compliance Context | ASTM D624, ISO 37, ISO 6982, DIN 53515 |
| Software | Automated real-time data acquisition, spectral evaluation, and GLP-compliant storage |
| Measurement Principle | Torque-based viscoelastic stress decay under constrained strain in rotational rheometric configuration |