Rubber & Plastic Industry Specialized Instruments
Filter
Showing 91–120 of 171 results
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HC3500 |
| Price | USD 3,650 (FOB Jiangsu) |
| Temperature Range | Ambient to 1000 °C |
| Display | 7-inch TFT LCD Touchscreen |
| Sample Capacity | 4 parallel positions |
| Heating Zone Length | 260 mm |
| Furnace Tube Dimensions | Ø45 mm × 600 mm |
| Chamber Dimensions | Ø45 mm × 350 mm |
| Heating Element | High-Temperature Alloy Resistance Wire |
| Temperature Control | PID with Multi-Stage Programmable Ramp/Soak Profiles |
| Temperature Uniformity | ±5 °C across working zone |
| Sensor Resolution | 0.1 °C |
| Gas Control | Dual Mass Flow-Controlled Inlets (N₂ only), Auto-Switching per Program Step |
| Cooling Method | Lid-Open Forced-Air Rapid Cool-down |
| Power Supply | AC 220 V / 50 Hz, 600 W |
| Overall Dimensions | 416 × 325 × 289 mm |
| Compliance | GB/T 3515–2005, GB/T 13021–1991, GB/T 2951.41–2008, ISO 6964:2015, IEC 60811-4-1:2012, ASTM D1606 (referenced), JTG E50 T1165–2006 |
| Brand | aboni |
|---|---|
| Origin | Germany |
| Model | HT3 |
| Measurement Principle | Calcium Hydride Reaction (Direct Absolute Moisture Quantification) |
| Resolution | 0.01 mg / 1 ppm / 0.0001 % H₂O |
| Sample Type Compatibility | Plastic pellets, granules, powders, and molded polymer components |
| Interface | USB-connected to Windows PC |
| Output | Auto-generated PDF report with timestamp, sample ID, moisture content, and operator metadata |
| Calibration | Calibration-free across polymer types |
| Vacuum Requirement | None |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DH-G1001B |
| Price Range | USD 9,800 – 13,900 |
| Temperature Range | Ambient to 999.9°C |
| Heating Zone Length | 300 mm |
| Combustion Tube Dimensions | Ø32 mm × 450 mm |
| Heating Element | Resistance Wire |
| Display | 7-inch Capacitive Touchscreen |
| Gas Flow Control | Dual-channel Float-type Flowmeter (Optional Mass Flow Controller) |
| Flow Ranges | 3 L/min (0.1 L/min resolution, for wire & cable) or 250 mL/min (12.5 mL/min resolution, for pipe & fitting) |
| Temperature Control | PID Programmable Controller with Auto-segment Memory |
| Crucible Options | (1) Wire/Cable: 93 mm total length (70 × 16 × 11 mm cavity) |
| (2) Pipe/Fitting | 72 mm total length (55 × 7 × 9 mm cavity) |
| Calculation Engine | Automatic black content, ash content, and filler content computation from user-input mass values |
| Data Output | Integrated thermal printer |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 1.5 kW |
| Dimensions (W × D × H) | 30 × 49 × 50 cm |
| Thermal Insulation | Nano-fiber Blanket for Uniform Furnace Temperature Distribution |
| Compliance | GB/T 13021–2023 (ISO 6964), GB/T 2951.41–2008 (IEC 60811-4-1), JB/T 4278.17–2011, JTG E50–2006 (T1165) |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DH900B |
| Pricing | Available Upon Request |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | RS-900B |
| Display | 7-inch capacitive touchscreen |
| Temperature Range | Ambient to 1000 °C |
| Control Method | PID programmable temperature controller with auto-segment memory |
| Furnace Tube Dimensions | Ø42 mm × 800 mm |
| Rated Power | 4 kW |
| Heating Element | Resistance wire |
| Power Supply | AC 220 V, 50/60 Hz |
| Compliance | GB/T 17650.1–2–1998, IEC 60754-1/2:1994, EN 50305, BS 6853 Annex B |
| Dual-function mode | Halogen gas evolution testing & carbon black content analysis |
| Optional accessory | Rapid cooling unit |
| Insulation material | Nano-ceramic fiber blanket |
| Integrated auxiliary modules | pH meter, conductivity meter, magnetic stirrer |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JH-6020B |
| Temperature Range | Ambient to 300 °C |
| Heating Rate Options | 120 °C/h or 50 °C/h |
| Temperature Control Accuracy | ±1 °C (VST), ±2 °C/6 min (HDT) |
| Temperature Measurement Accuracy | ±0.5 °C |
| Deflection Measurement Resolution | 0.001 mm |
| Max Deflection Error | ±0.005 mm |
| Vicat Penetration Depth | 1.00 mm ±0.01 mm |
| Standard Test Loads | 10 N, 50 N (VST) |
| Bending Stresses | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) (HDT) |
| Sample Supports | 3 independent test frames with selectable spans (64 mm for flatwise placement |
| Heating Medium | Methyl silicone oil (kinematic viscosity ≤200 cSt |
| Max Heating Power | 3 kW |
| Cooling Method | Natural convection |
| Power Supply | 220 V ±10%, 50 Hz, 15 A |
| Compliant Standards | GB/T 1633–2000 (ISO 306:1994), GB/T 1634.1–2004 (ISO 75-2:2003), GB/T 1634.2–2004, GB/T 1634.3–2004, GB/T 8802–2001 (ISO 2507:1995), ASTM D1525, ASTM D648 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-50T |
| Price Range | USD 4,200 – 7,000 |
| Total Force | 500 kN (50 metric tons) |
| Working Pressure | 16 MPa |
| Platen Size | 400 × 400 mm |
| Unit Platen Pressure | 3.125 MPa |
| Number of Heating Zones | 2 |
| Platen Spacing | 125 mm |
| Piston Stroke | 250 mm |
| Piston Rising Speed | 12 mm/s |
| Heating Power per Platen | 3 kW |
| Max Operating Temperature | 300 °C |
| Net Weight | ~1,200 kg |
| Gross Weight | ~1,600 kg |
| Motor Specifications | High-Pressure Pump — 1.5 kW, 1400 rpm |
| Overall Dimensions | 1295 × 450 × 1686 mm |
| Brand | Labtech Engineering |
|---|---|
| Roll Diameter | 150 mm |
| Configuration | Horizontal Open Two-Roll Mill |
| Drive Type | Variable-Frequency AC Motor with Precision Speed Control |
| Roll Surface | Chrome-Plated Steel |
| Roll Gap Adjustment | Manual Micrometer with Digital Readout |
| Safety Compliance | CE Marked, EN ISO 13857 & EN 61800-5-1 Compliant |
| Construction | Heavy-Duty Cast Iron Frame with Reinforced Bearing Housings |
| Temperature Control Option | Optional Water-Cooled or Electrically Heated Rolls (±1 °C Stability) |
| Power Supply | 380–415 V, 3-Phase, 50/60 Hz |
| Dimensions (L×W×H) | 1850 × 920 × 1280 mm |
| Weight | Approx. 1,450 kg |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Instrument |
| Model | 895 Professional |
| Pricing | Upon Request |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | M-VS 3000 |
| Cutting Die Diameter | 45 mm |
| Max. Sample Thickness | ≤ 20 mm |
| Volume Reproducibility | ±0.1 % |
| Nominal Sample Volume | ~15 cm³ |
| Adjustable Cutting Cycle Time | 1–15 s |
| Dimensions (H×W×D) | 600 × 430 × 380 mm |
| Net Weight | ~50 kg |
| Minimum Operating Air Pressure | 5.0 bar |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | MDR 3000 |
| Standard Compliance | ISO 6502, ASTM D5289, DIN 53529 |
| Cavity Type | Sealed Dual-Conical |
| Drive System | Direct-Drive DC Servo Motor |
| Oscillation Frequency | 1.667 Hz |
| Amplitude Range | Software-Controlled ±0.01° to 5° (mechanical fixed option: 0.5°) |
| Temperature Range | Ambient to 232 °C |
| Measured Parameters | Torque (dN·m), Temperature (°C), Frequency (Hz), Strain (%), Derived Moduli (S′, S″, S*, tan δ) |
| Cavity Material | Hardened & Polished Stainless Steel |
| Enclosure | Anodized Aluminum Alloy Housing |
| Control Interface | Dedicated PC with MonControl v5.x (32-bit Windows-based Analysis Suite) |
| Data Output | Real-time torque/temperature curves, modulus profiles, cure kinetics (ts1, tc50, tc90), hysteresis analysis |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | MV 3000 |
| Standards Compliance | ISO 289:2005, ASTM D1646, DIN 53523, BS 903 Part A58, JIS K6300, GOST 10722–76 |
| Rotor Options | Large rotor (38.10 mm), Small rotor (30.48 mm) |
| Rotational Speed | 2 rpm ± 0.02 rpm |
| Temperature Range | Ambient to 232 °C |
| Temperature Accuracy | ±0.03 °C |
| Measurement Units | Mooney Units (MU), °C / °F, min:min or min:sec |
| Test Modes | Mooney Viscosity, Mooney Scorch, Stress Relaxation, Mold Release Performance, Delta Mooney |
| Sealing | Long-life elastomeric seal assembly |
| Control System | Digital microprocessor-based PID temperature and torque control |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | PO 3000 Plastometer Aging Oven |
| Construction | Stainless Steel Enclosure |
| Heating Chambers | 4 Independent PID-Controlled Zones |
| Temperature Range | Ambient to 200 °C (Standard Operating Point: 140 ± 0.2 °C) |
| Temperature Recovery Time | ≤ 1 min after Sample Insertion |
| Max. Sample Capacity | 48 specimens (12 per Tray × 4 Trays) |
| Air Exchange Rate | 0–120 air changes/hour (adjustable) |
| Chamber Dimensions (W × H × D) | 500 × 120 × 280 mm |
| Max. Power Consumption | 2.5 kW |
| Compliance | ASTM D3194, BS 903-A59 |
| Safety Features | Overheat Protection, Stability Monitoring, Timeout Alert |
| Brand | MonTech |
|---|---|
| Origin | Germany |
| Model | V-MV 3000 |
| Standards Compliance | ISO 289:2005, ASTM D1646, DIN 53523, DIN 53525 Parts 1–3, BS 903 Part A58, AFNOR T43-00/005, JIS K6300, GOST 10722–76 |
| Rotor Options | Large rotor (38.10 mm), Small rotor (30.48 mm) |
| Rotational Speed Range | 0–50 rpm, adjustable in 0.01 rpm increments |
| Temperature Range | Ambient to 232 °C, control accuracy ±0.03 °C |
| Measurement Units | Mooney Units (MU), °C / °F, time (min:min or min:sec) |
| Test Modes | Mooney viscosity, Mooney scorch, stress relaxation, mold release evaluation, Delta Mooney, variable Mooney, stepwise stress relaxation, programmable multi-step test sequences |
| Sealing | Long-life precision sealing system |
| Application Scope | QC, R&D, and production fast-check for raw rubber, compounded elastomers, and thermoplastic elastomers (TPEs) |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8005 |
| Pricing | Upon Request |
| Brand | KJ GROUP (Shenyang Kejing) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MSK-ESC-R2R |
| Pricing | Upon Request |
| Electrode Configuration | Linear 5-needle spinneret |
| Coating Width | 160 mm |
| Substrate Travel Speed | 2.2–117.2 mm/s |
| Heating Platform Max Temp | 100 °C |
| Temperature Control Accuracy | ±1 °C (PID) |
| High-Voltage Output | 0–50 kV, max 1 mA |
| Needle OD | 0.9 mm |
| Needle ID | 0.6 mm |
| Needle Length | 12 mm |
| Needle Spacing | 25 mm |
| Needle-to-Heater Distance Range | 70–235 mm |
| Syringe Pump Flow Rate | 0.1–45 mm/min (linear displacement) |
| Syringe Volume | 250 mL |
| System Footprint | 805 × 435 × 565 mm (L×W×H) |
| Brand | EUROTECH |
|---|---|
| Origin | Italy |
| Model | Multilayer Blown Film |
| Configuration Options | 3-, 5-, 7-, and 9-layer coextrusion capability |
| Human-Machine Interface | 7-inch industrial touchscreen HMI |
| Connectivity | Ethernet (LAN) interface |
| Data Export | USB port for raw process data logging |
| Commercial Status | Imported equipment distributed via authorized channel |
| Brand | North Guang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8102 |
| Quotation | Upon Request |
| Stroke Range | 0–100 mm |
| Worktable Dimensions | 245 mm × 245 mm |
| Overall Dimensions | 420 mm × 360 mm × 580 mm |
| Operating Air Pressure | 0.4 MPa |
| Brand | North Guang Precision Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Accuracy | ±1% (10⁴–10⁹ Ω), ±5% + 2 digits (10¹⁰–10¹¹ Ω), ±5% + 5 digits (10¹²–10¹³ Ω), ±10–15% + 5 digits (>10¹⁴ Ω) |
| Compliance | GB 4386-84, GB 6650-86, GB 1410, GB 10580 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | B121 |
| Price | USD 1,200 (FOB Beijing) |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Measurement Principle | Guarded Three-Electrode Ring Method |
| Resistance Range | 1.0×10³ – 2.0×10¹² Ω |
| Resistivity Range | 1.0×10³ – 2.0×10¹² Ω·m |
| Sheet Resistance Range | 1.0×10⁴ – 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ – 0.1×10¹² Ω (auto-ranging) |
| Power Supply | 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 × 90 × 275 mm |
| Net Weight | ≤3.0 kg |
| Standard Electrode | Triple-ring coaxial electrode (center cylinder Ø50 mm × 40 mm h |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWR |
| Power Supply | AC 220 V ±10%, 50 Hz, 30 A |
| Heating Power | 2.5 kW |
| Heating Medium | Methyl Silicone Oil (flash point ≥300 °C, kinematic viscosity 200 cSt, 20 L required) |
| Sample Stands | Three independent test stations per bath |
| Deformation Measurement | Linear encoder-based dial indicator (resolution 0.001 mm, accuracy ±0.01 mm) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Heating Rates | 120 ±5 °C/h (12 ±1 °C/6 min) or 50 ±3 °C/h (5 ±0.5 °C/6 min) |
| Deformation Range | −0.1 to 5.0 mm |
| Cooling Method | Natural convection above 150 °C |
| Maximum Settable Temperature | 300 °C with over-temperature cut-off |
| Load Rod + Indenter Mass | 88 g |
| Standard Loads | Vicat GA = 10.0 N ±0.2 N (1000 g), GB = 50.0 N ±1.0 N (5000 g) |
| HDT fiber stress options | 0.45 MPa (Method B), 1.80 MPa (Method A), 8.00 MPa (Method C) |
| Compliance | ASTM D1525, ASTM D648, ISO 306:2004, ISO 75-1:2013, GB/T 1633–2000, GB/T 1634.1–2004, GB 8802 |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | 10012006 |
| Operating Temperature Range | −80 °C to +100 °C |
| Sample Capacity | 5 specimens (ASTM D1329) or 10 specimens (ISO R 974) |
| Cooling Options | Dual-coil test bath with compatibility for liquid nitrogen, external cryogenic chiller, or dry-ice-based regulation |
| Bath Volume | 25 L |
| Integrated Dual-Stage Compressor System | Yes (−80 °C capability) |
| Compliance Standards | ASTM D1329, ISO R 974, TR-Test method |
| Safety Features | Automatic pendulum release mechanism, guarded sample positioning, mechanical interlock for operator protection |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Model | HDT/VICAT |
| Maximum Temperature | 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ≤0.2 °C |
| Temperature Stability (Oil Bath Fluctuation) | ±0.2 °C |
| Heating Rates | 50 °C/hr, 120 °C/hr, or Custom |
| Displacement Resolution | 0.001 mm |
| Displacement Accuracy | <0.01 mm |
| Sample Immersion Depth | ≥35 mm |
| Span Between Supports (HDT) | 100 mm (optional 64 mm) |
| Sample Length (HDT) | Up to 102 mm |
| Test Stations | 6 independent positions |
| Weight Load Range | 1–2048 g (binary HDT weights), plus 10 N and 50 N VICAT needles |
| Cooling System | Integrated stainless-steel water-jacketed oil bath with external 18 °C coolant |
| Safety Features | Nitrogen purge interface, physical barrier (mesh screen) between heating/stirring components and sample zone, dual stirrers and heater isolated from test chamber |
| Compliance | ASTM D648, ASTM D1525, ISO 75-1/2/3, ISO 306, GB/T 1634, GB/T 1633, DIN 53461 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HY-760BX |
| Pricing | Upon Request |
| Control System | PLC-based Touchscreen Interface |
| Test Stations | 12 independent channels |
| Max. Sample Capacity | 12 specimens (standard configuration) |
| Specimen Type | Dumbbell-shaped or square cross-section rubber/plastic strips |
| Clamping Method | Four-sided mechanical clamping |
| Stroke Adjustment Range | 0–100 mm (continuously adjustable) |
| Test Speed | 60–300 rpm ±10 rpm |
| Drive Mechanism | Motor-driven eccentric cam + precision linkage system with linear guide columns |
| Failure Detection | Real-time individual channel break detection with autonomous counter halt |
| Safety Features | Interlocked transparent safety guard enclosure |
| Compliance Standards | GB/T 1688–2021, ISO 6943:1985, ASTM D430–18, DIN 53509-1:2006 |
| Brand | OMICRON |
|---|---|
| Origin | Austria |
| Model | CMC 256plus |
| Input Voltage Range | 85–264 VAC, 45–65 Hz |
| Operating Temperature | 0–50 °C |
| Weight | 16.0 kg |
| Dimensions | 450 × 145 × 390 mm |
| Compliance | IEC 61000-4 (EMC), IEC 61010-1 (Safety), ISO 9001 |
| Output Accuracy Class | Up to 0.2 |
| Synchronization | GPS / IRIG-B (<1 µs typical timing error) |
| Communication Protocols | IEC 61850 (GOOSE, SV, MMS), IEEE C37.118-1/2 |
| Software Platform | OMICRON Control, Test Universe |
| Brand | Pinzhichuangsi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | XR-14 |
| Price | USD 2,600 (FOB Beijing) |
| Stirring Speed | 14,000 rpm ± 200 rpm |
| Speed Range | 2,000–24,000 rpm (adjustable) |
| Speed Resolution | 1 rpm |
| Speed Accuracy | ≤ 0.1% FS |
| Sample Container | Cylindrical borosilicate glass vessel (ID 58 mm, OD 63 mm, H > 100 mm) |
| Stirrer Discs | Two interchangeable discs — natural rubber latex disc (Ø 20.83 ± 0.03 mm, t 1.57 ± 0.05 mm) |
| Stirrer Shaft Tip Diameter | 6.3 mm |
| Operating Ambient | 10–40 °C, < 85% RH |
| Power Supply | 220 V ±10%, 50 Hz, 1500 W |
| Dimensions (W×D×H) | 400 × 350 × 720 mm |
| Cooling System | Integrated recirculating coolant pump |
| Display | LED digital readout via frequency converter interface |
| Compliance | GB/T 8301–2008, SH/T 1151–1998 |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-QC |
| Operating Temperature Range | 140–160 °C |
| Analysis Time per Sample (incl. dissolution) | ≤30 min |
| Detection | IR5 Selective Infrared Detector (C–H stretch, 3.42 µm) |
| Concentration Sensitivity | 0.125 mg/mL (S/N ≥60) |
| Optional Detectors | Dual Capillary Viscometer (IV), IR4 |
| Column Configuration | Pre-packed High-Throughput GPC Columns (macroporous crosslinked polystyrene/divinylbenzene, calibrated for polyolefins) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data handling |
| Sample Throughput | Up to 24 samples unattended |
| Dimensions | Benchtop (W × D × H: 750 × 600 × 550 mm) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PREP mc2 |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | TREF |
| Sample Capacity | 5 positions |
| Analysis Time per Sample | ~6 hours (standard conditions) |
| Detection | IR4 Infrared Detector (standard), optional Multi-Angle Light Scattering (MALS) and Capillary Viscometer |
| Minimum Operating Temperature | –20 °C |
| Software-Controlled Automation | Full remote operation and diagnostic capability |
| Solvent Handling | Closed-loop, minimal solvent consumption, no manual solvent contact required |
| Upgrade Path | Compatible with CRYSTAF-TREF hyphenated configuration |
| Compliance | Designed for GLP-compliant laboratories |