Rubber & Plastic Industry Specialized Instruments
Filter
Showing 121–150 of 171 results
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rheoline MDR |
| Price | Upon Request |
| Standard Compliance | ISO 6502, ASTM D5289 |
| Oscillation Frequency | 1.67 Hz |
| Oscillation Amplitude Options | 0.5° (standard), 1.0° or 3.0° (optional) |
| Temperature Range | 35–250 °C |
| Temperature Control | Digital PID |
| Torque Units | in·lb, dN·m |
| Temperature Units | °C, °F |
| Pressure Units (optional) | psi, kg/cm² |
| Time Format | min/sec, min/decimal, sec |
| Output Parameters | Elastic Modulus (G′), Viscous Modulus (G″), Tan δ, Curing Rate, Cavity Pressure (optional) |
| Data Storage | Microsoft Access or SQL database |
| Optional Accessories | Programmable multi-zone heating, Eccentric oscillating die, Cavity pressure transducer, Automated sample loader, Volumetric sample cutter |
| Software | Windows-based proprietary test platform with SPC module (optional), GLP/GMP-compliant audit trail support |
| Key Parameters | Brand: Pinzhichuangsi |
|---|---|
| Origin | Beijing, China |
| Model | XR-14-2 |
| Speed Range | 2000–20,000 rpm |
| Nominal Test Speed | 14,000 ± 200 rpm |
| Speed Accuracy | ≤0.1% |
| Resolution | 1 rpm |
| Display | LED |
| Power Supply | 220 VAC, 50 Hz, 2000 VA |
| Dimensions (W×D×H) | 400 × 350 × 740 mm |
| Net Weight | ~30 kg |
| Operating Environment | 10–40 °C, <85% RH |
| Continuous Operation | ≥60 min |
| Stirring Disk (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Sample Container | Height 130 ± 2 mm, ID 58 ± 2 mm |
| Compliance | ISO 35 |
| Brand | Qigao Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HSY-8146H |
| Temperature Range | Ambient to 162 °C |
| Temperature Resolution | 0.1 °C |
| Brand | Ray-Ran |
|---|---|
| Origin | United Kingdom |
| Model | MFR200 |
| Load Cell Resolution | 0.1 g |
| Temperature Range | Ambient to 450 °C (±0.2 °C stability) |
| Standard Orifice | 2.095 mm diameter × 8.00 mm length |
| Piston Travel | 30 mm |
| Cut-Off Timing Accuracy | ±0.1 s |
| Weight Loading Options | Manual or Pneumatic (up to 11 bar, equivalent to ~21.6 kg force) |
| Compliance | ASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682 |
| Brand | Ray-Ran |
|---|---|
| Origin | Netherlands |
| Model | MFR300 |
| Temperature Range | 0–450 °C (500 °C optional) |
| Temperature Accuracy | ±0.10 °C |
| Temperature Resolution | 0.10 °C |
| Piston Displacement Resolution | ±0.02 mm |
| Heating Zones | Dual-zone |
| Power Supply | 110 V/60 Hz or 220 V/50 Hz, 10 A fuse |
| Connectivity | Wi-Fi, USB, Ethernet |
| Compliance | ISO 1133, ASTM D1238, GB/T 3682 |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Model | HRWK-300 |
| Temperature Range | Ambient to 300 °C |
| Heating Rates | 50 °C/h and 120 °C/h |
| Deformation Measurement Range | −1.000 mm to +10.000 mm |
| Vicat Needle Tip Area | 1.00 ± 0.015 mm² |
| Sample Holder Thermal Expansion Coefficient | < 0.005 mm/100 °C |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 306, ISO 75, ISO 2507, ASTM D 1525, ASTM D 648 |
| Brand | Saicheng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RSY-R2 |
| Pricing | Upon Request |
| Brand | Shanda |
|---|---|
| Model | SD-FSX |
| Origin | Shandong, China |
| Category | Rubber & Plastic Industry–Specific Instrument |
| Compliance | GB/T 6030–2006 |
| Imaging Sensor | 5 MP CMOS |
| Resolution Options | 640×480, 1024×768, 1280×1024, 2592×1944 |
| Interface | USB 2.0 |
| Calibration | Integrated micrometer scale with pixel-to-µm mapping |
| Output Formats | PDF, PNG/JPEG, Excel (.xlsx) |
| Software Compatibility | Windows XP/7/10 (32/64-bit) |
| Image Segmentation Modes | Automated thresholding + manual ROI selection |
| Standard Reference Libraries | ISO-aligned carbon black dispersion image library + user-customizable library |
| Data Export | Particle count, equivalent circular diameter (µm), projected area (µm²), grayscale histogram, particle size distribution curve, dispersion rating (0–10 scale per GB/T 6030) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SMV-300/300RT |
| Mooney Viscosity Range | 0–200 M (extendable to 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotor Speed (SMV-300RT only) | 0.5–5 rpm |
| Rotor Type | L-shaped |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Heating Method | Thin-film heater with optimized PID control |
| Compression Method | Pneumatic cylinder actuation |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points programmable) |
| Scorch Point Setting Range | 0–99.9 M (up to 10 points programmable) |
| Data Logging & Statistical Analysis | Built-in |
| Brand | EUROTECH |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T50 |
| Pricing | Upon Request |
| Brand | SYSTESTER |
|---|---|
| Origin | Shandong, China |
| Model | GTR-704R |
| Test Range | 10–15,000 s/100 mL (standard) |
| Resolution | 0.1 s/100 mL |
| Specimen Count | 1 |
| Pressure Range | 20 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area | 1.0 in² (0.25 in² / 0.1 in² optional) |
| Max Specimen Thickness | ≤5 mm |
| Test Gas | Clean Compressed Air (user-supplied) |
| Air Supply Pressure | 0.3–1.0 MPa |
| Interface | Ø6 mm pneumatic fitting |
| Dimensions (L×D×H) | 370 × 320 × 220 mm |
| Power | AC 220 V, 50 Hz |
| Net Weight | 20 kg |
| Standards Compliance | ISO 5636-5, ASTM D726, TAPPI T460, GB/T 36363–2018 |
| Brand | TA Instruments |
|---|---|
| Origin | Germany |
| Model | MV one |
| Motor Speed Range | 0.1–10 rpm (standard test at 2 rpm) |
| Rotor Options | 38.10 mm (large) and 30.48 mm (small) diameter |
| Compliance | ASTM D1646, ISO 289, DIN 53523 |
| Temperature Control | High-precision, PID-regulated, ±0.1 °C stability |
| Torque Measurement | Auto-calibrating, high-resolution digital torque sensor |
| Frame | Ultra-rigid monolithic steel construction |
| Drive System | Direct-drive brushless motor with <0.01 rpm speed resolution |
| Software | Scarabaeus v5.x (multi-language, GLP-compliant audit trail, FDA 21 CFR Part 11 ready) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Eurolab 16 |
| Screw Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 1.25 kW or 2.5 kW |
| Speed Range | 50–1000 rpm |
| Max Operating Pressure | 200 bar |
| Barrel Temperature Zones | 6–10 |
| Max Barrel Temperature | 350 °C (optional 450 °C) |
| Throughput | 0.5–5 kg/h |
| Drive System | PLC-controlled servo motor with real-time torque & temperature monitoring |
| Control Interface | Color LCD touchscreen with embedded HAAKE PolyLab software |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | MiniJet Pro |
| Maximum Injection Pressure | 1200 bar |
| Compressed Air Supply Pressure (Max) | 10 bar |
| Barrel Temperature Range | Up to 400 °C |
| Mold Temperature Range | Up to 250 °C |
| Sample Mass Capacity | 3–5 g per shot |
| Control Interface | Digital LCD Controller with Parameter Storage |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | Process 11 |
| Drive Motor Power | 1.5 kW |
| Screw Diameter | 11 mm |
| L/D Ratio | 40 |
| Speed Range | 10–1000 rpm |
| Barrel Material | Nitrided Steel 1.7365 (EN 40B) |
| Max Operating Temperature | 350 °C (optional 450 °C) |
| Max System Pressure | 100 bar (with pressure monitoring) |
| Heating Zones | 7 × 5D electric heating (optional water cooling) |
| Dimensions (L×W×H) | 820 × 480 × 410 mm |
| Weight | 55 kg |
| Sample Requirement | ~20 g |
| Throughput | up to 2.5 kg/h |
| Barrel Opening | Horizontal split, two-piece design |
| Control Interface | Integrated color touchscreen |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | TSE 24 |
| Price | Upon Request |
| Screw Diameter | 24 mm |
| L/D Ratio | up to 40:1 |
| Motor Power | 5.5–11 kW |
| Max Speed | 500–1000 rpm |
| Max Temperature | 400 °C |
| Max Pressure | 100 bar |
| Temperature Zones | 7–10 independently controlled |
| Throughput | 2–30 kg/h |
| Drive Type | DC or AC servo motor |
| Barrel Construction | Horizontal split, hinged modular segments |
| Screw Design | Intermeshing co-rotating, fully configurable |
| Control Interface | 10.4" color touchscreen with HAAKE PolyLab OS software |
| Data Export | Real-time CSV/Excel export via Ethernet/USB |
| Compliance | CE, ISO 9001, compliant with GLP/GMP documentation requirements for process development |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory-Scale Twin-Screw Extruder |
| Model | Pharma 11 |
| Minimum Throughput | 20 g/h |
| Maximum Throughput (GMP Mode) | 2.5 kg/h |
| Application Scope | Preclinical Formulation Development, Clinical Trial Material (CTM) Manufacturing, Scale-Up Studies |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pharma 16 |
| Price | Upon Request |
| Screw Diameter | 15.6 mm |
| Barrel Diameter | 16 mm |
| L/D Ratio | 25:1 to 40:1 (modular) |
| Motor Power | 2.5 kW |
| Max Screw Speed | 1000 rpm |
| Free Volume | 6–109 cm³ |
| Voltage/Phase/Current | 400 V / 3-phase / 20 A |
| Throughput | 1–5 kg/h |
| Barrel Material | Pharmaceutical-grade stainless steel (e.g., AISI 316L) |
| Drive | Brushless AC inverter motor |
| Control System | Touchscreen HMI with PLC-based data acquisition |
| Compliance | Designed per EU GMP Annex 1 & ICH Q5A/Q5C principles |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Pharma 24 |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | Pharma Mini |
| Motor Power | 400 W |
| Speed Range | 10–360 rpm |
| Screw Configuration | Conical Co-rotating or Counter-rotating |
| Max Operating Temperature | 280 °C |
| Heating Time (22–170 °C) | < 10 min |
| Free Volume | 3 g (4 mL) |
| Screw Material | Medical-Grade Stainless Steel 1.4112 (AISI 440B) |
| Barrel Material | High-Performance Pharmaceutical-Grade Stainless Steel M340 |
| IP Rating | IP54 |
| Production Capacity | Up to 100 g/h |
| Controller | Touchscreen with User-Level Access Control and Password Protection |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Model | TY-FSX |
| Detection Range | 1 µm – 10 mm |
| Imaging Resolution | 2592 × 1944 (5 MP CMOS camera) |
| Optical Magnification | 100× |
| Image Size Options | 640×480, 1024×768, 2048×1536, 2592×1944 |
| Power Supply | 220 V / 2 A / 50 Hz |
| Compliance | GB/T 6030–2006 |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-7003 |
| Screw Diameter | 20 mm |
| Clamping Force | 5 T (adjustable up to 5 T via dual-toggle mechanism) |
| Maximum Shot Volume | 25 cm³ |
| Barrel Temperature Range | Up to 360 °C (3-zone heating) |
| Temperature Control Accuracy | ±0.5 °C (steady-state) |
| Power Supply | Single-phase AC 220 V ±10%, 50 Hz, 2.2 kW |
| Overall Dimensions | 1700 × 500 × 950 mm (L×W×H) |
| Length-to-Diameter Ratio | 20:1 |
| Injection Pressure | Up to 57 MPa (113 MPa with force-multiplying system) |
| Mold Opening Stroke | 70 mm (excluding mold thickness) |
| Hopper Capacity | 0.2 L |
| Injection Stroke Range | 0–80 mm |
| Injection Resolution | 0.1 mm |
| Feed Speed | 0.1–60 rpm (max 100 rpm, torque reduced beyond 60 rpm) |
| Safety | Dual mechanical & electronic interlock with acrylic safety guard |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TY-7006B Single-Speed |
| Roller Diameter | Ø120 mm |
| Roll Working Length | 320 mm |
| Roll Gap Adjustment Range | 0–3 mm |
| Roll Speed Ratio | 1:1.35 |
| Rear Roll Speed | 9.80 m/min |
| Front Roll Speed | 8.03 m/min |
| Batch Capacity | 0.5–1 kg |
| Motor Power | 2.2 kW (BWO220-23 Gearmotor) |
| Overall Dimensions (L×W×H) | 1350 × 770 × 1350 mm |
| Net Weight | ~400 kg |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | TY-7007A |
| Price Range | USD 9,800 – 13,900 |
| Temperature Range | Ambient to 300 °C |
| Control System | PLC-based color touchscreen HMI |
| Heating Method | Electric heating |
| Temperature Accuracy | ±3 °C |
| Roll Dimensions | Ø120 mm × 350 mm (L) |
| Roll Gap Adjustment | 0–10 mm (motorized, micrometer-graduated) |
| Roll Material | Hard-chrome-plated alloy steel |
| Surface Hardness | HRC 58–62 |
| Surface Finish | Mirror-polished chrome |
| Roll Speed | 0–60 rpm (dual servo-driven, independently adjustable) |
| Speed Ratio Control | Continuously variable (1:1 to 1:3.5) |
| Total Power Consumption | 4 kW |
| Safety Systems | Mechanical pull-bar emergency stop, foot-activated reverse function, dual-hand safety interlock |
| Overall Dimensions (W×D×H) | 1030 × 520 × 1410 mm |
| Electrical Supply | AC 380 V, 3-phase, 5-wire |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-7008 |
| Screw Diameter | 20 mm |
| Length-to-Diameter Ratio | 1:25 |
| Overall Dimensions | 390 mm × 1500 mm × 1100 mm |
| Drive Power | 2.2 kW |
| Heating Zones | 5 (4 barrel + 1 die) |
| Screw Speed Range | 0–80 rpm (variable-frequency control) |
| Screw Material | 38CrMoAlA alloy steel, nitrided surface hardness HRC 55–60, surface roughness Ra < 0.4 µm, nitrided layer depth > 0.6 mm |
| Barrel Material | 38CrMoAlA alloy steel, same surface treatment as screw |
| Melt Pressure Range | 0–35 MPa |
| Filtration Mesh | 5–40 µm |
| Cooling System | 4-channel forced-air cooling with multi-wing fans |
| Gearbox | Hardened gear reducer, reduction ratio 18:1 |
| Motor | Panasonic servo motor |
| Gearbox Supplier | LIMIN (Taiwan) |
| Weight | 380 kg |
| Electrical Supply | AC 380 V, 50 Hz, 3-phase 5-wire |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TP 691 |
| Pricing | Upon Request |
| Measurement Principle | Microscopic Filtration & Manual Particle Counting |
| Detection Threshold | ≥5 µm (maximum dimension) |
| Microscope Magnification | 100× with Integrated Illumination |
| Contamination Rating Range | NAS 1638 Classes 4–12 |
| Dimensions | 410 mm × 310 mm × 230 mm |
| Weight | 6.4 kg |
| Compliance Standards | DL/T 432, GB/T 20082, ISO 4406, NAS 1638, GB/T 18854, ISO 11171, GJB 420B, GJB 380.4A |
| Brand | Tinius Olsen |
|---|---|
| Origin | USA |
| Model | 603HDTV, 303HDTV |
| Compliance Standards | ISO 75-1/2, ISO 306, ASTM D648, ASTM D1525 |
| Maximum Simultaneous Test Positions | 6 (603HDTV), 3 (303HDTV) |
| Oil Bath Stations | 6 (603HDTV), 3 (303HDTV) |
| Load Application | Pneumatic vertical loading with air-bearing guide ring |
| Displacement Resolution | 0.001 mm |
| Load Accuracy | Certified for 0.45 MPa (ISO 75) and 1.0 MPa / 5.0 MPa (ISO 306) |
| Cooling System | Integrated heat exchanger (603HDTV) |
| Software | Horizon HDV with SPC, audit trail, CFR 21 Part 11–ready configuration options |
| Data Export Formats | HTML, CSV, PDF |
| Password Protection | Dual-level authentication |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tracking Index |
| Voltage Range | Up to 600 V DC/AC |
| Dropping Interval | 30 s ± 1 s |
| Droplet Volume | 20 mm³ ± 2 mm³ |
| Droplet Height | 35 mm (adjustable within 30–40 mm) |
| Electrode Force | 1 N (spring-loaded, calibrated) |
| Electrode Material | Platinum-tipped stainless steel |
| Sample Chamber | High-dielectric-strength insulated enclosure with hinged acrylic lid |
| Safety Interlock | Automatic circuit disconnection upon lid opening |
| Meters | 600 V full-scale voltmeter, 1 A full-scale ammeter |
| Control Panel | Start/Stop switch, main power switch, integrated timer |
| Brand | TianYuan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TY-5006UA |
| Temperature Control Range | RT to 300 °C |
| Heating Rate Options | (120 ± 10) °C/h or (50 ± 5) °C/h |
| Temperature Resolution | 0.1 °C |
| Deformation Measurement Range | 0–1.5 mm |
| Deformation Accuracy | ±0.001 mm |
| Sample Support Span | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | < 0.005 mm/100 °C |
| Load Rod & Platter Mass | 68 g |
| Heating Power | 4 kW |
| Dimensions (W × D × H) | 540 × 520 × 970 mm |
| Cooling Method | Natural cooling above 150 °C |
| Bath Medium | Methyl silicone oil (kinematic viscosity ~200 cSt) or transformer oil |
| Test Stations | 3 independent stations |
| Standard Compliance | GB/T 1633, GB/T 1634.1–3, GB/T 8802, ISO 306:2013, ISO 75-1–3:2003, ASTM D1525, ASTM D648 |
| Brand | TYTESTER |
|---|---|
| Model | TYMP-II |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 1,400 – 2,100 |
| Wheel Linear Speed | 12 m/s |
| Coarse Wheel Specification | G260APRI 170×40×32 mm, 32-grit |
| Fine Wheel Specification | G260APRI 170×40×32 mm, 80-grit |
| Worktable Diameter | 160×44 mm |
| Center Height | 214 mm |
| Grinding Stroke | 20 mm |
| Sample Dimensions (L×W×H) | >260 mm × ≤36 mm × ≤8 mm |
| Overall Dimensions | 500×400×314 mm |
| Weight | 80 kg |