Rubber & Plastic Industry Specialized Instruments
Filter
Showing 151–171 of 171 results
| Brand | Wallace |
|---|---|
| Origin | United Kingdom |
| Model | P14 |
| Type | Rapid Plastometer for Uncured Natural Rubber |
| Compliance | GB/T 3517–2022, ASTM D926 (equivalent methodology), ISO 2007 (Plasticity of Raw Rubber) |
| Calibration | Semi-automatic 1 mm gap calibration, load calibration, temperature calibration |
| Data Output | Sample ID tagging, timestamped results, traceable test records |
| Operation Modes | Single-value, median, or mean reporting |
| Display | Real-time digital readout of deformation under standardized load and temperature |
| Key | Brand: Wickert |
|---|---|
| Origin | Germany |
| Model | WLP S Series |
| Compliance | GB/T 6038, ISO 2393, ASTM D3182 |
| Type | Laboratory-scale hydraulic平板 vulcanizer for rubber sample curing |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | DHS (Laboratory Version) |
| Application | Offline Lab Use |
| Test Methods | ASTM D1238, ISO 1133, GB/T 3682, GB/T 9643, JIS K7210 |
| Automation Level | Fully Automated Sample Loading, Weight Switching, Melt Extrusion, Gravimetric MFR Calculation, and Self-Cleaning Cycle |
| Compliance | GLP-ready architecture with audit-trail-capable software logging |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.105 |
| Compliance Standards | JIS K 6249, ASTM D 926, ISO 7323 |
| Measurement Principle | Parallel-plate compression under standardized load and dwell time |
| Output Unit | Plastometric value (dimensionless, ×100 amplification of thickness reduction) |
| Load Application | Fixed dead-weight loading system |
| Test Duration | Standardized dwell time per method (e.g., 15 s per JIS K 6249) |
| Plate Geometry | Precision-ground parallel stainless steel plates |
| Sample Thickness Range | Compatible with 10 mm × 10 mm × ~2 mm vulcanized rubber specimens |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.105-AUTO |
| Standards Compliance | JIS K 6249, ASTM D 926, ISO 7323 |
| Sample Geometry | Cylindrical specimen (Φ16 mm × 10 mm height, volume 2.00 ± 0.02 cm³) |
| Platen Dimensions | Upper and lower plates Φ148 mm × 12 mm thick |
| Applied Load Range | 24.5 N (2.5 kgf) to 49.0 ± 0.05 N (5.0 kgf) |
| Dial Indicator Resolution | 0.01 mm |
| Maximum Travel | 20 mm |
| Data Output | Real-time thickness-vs.-time curve on PC display |
| Software Platform | Dedicated Windows XP-compatible application |
| Power Supply | 220 V AC, single-phase, 3 A, 50/60 Hz |
| Dimensions (W×D×H) | ≈365 × 250 × 500 mm |
| Weight | ≈15 kg |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.145-D |
| Standard Compliance | JIS Z 0237 |
| Specimen Dimensions | 25 mm × 150 mm (or 12 ± 0.5 mm × 150 mm) |
| Test Plate | SUS304, 50 mm × 125 mm × ≥1.1 mm |
| Load Range | 200 gf to 1,000 gf (±5 g tolerance) |
| Fixture Type | Upper hook-type, Lower flat chuck (30 mm width) |
| Vertical Travel | Max. 45 mm, motorized auto-stop actuation |
| Temperature Capability | Up to 150 °C |
| Timer Functions | Preheating time setting, fall-time measurement, programmable test duration |
| Optional Accessories | Low-temperature chamber, constant temperature/humidity chamber, in-chamber lighting, 90° peel test kit |
| Power Supply & Dimensions | Configuration-dependent |
| Brand | Yasuda |
|---|---|
| Origin | Japan |
| Model | No.170-AUTO |
| Temperature Range | −60 °C to 100 °C (dry ice cooling) |
| Heating Rate | 2 °C/min |
| Specimen Dimensions | W 6.35 ± 0.03 mm × L 64 mm × T 0.8–1.5 mm |
| Gauge Length | 40 mm |
| Angular Range | 0–270° (1° resolution) |
| Torque Application | Pulley-type weight system (5 g, 10 g, 20 g, 50 g) |
| Encoder Type | Rotary encoder for torsional angle measurement |
| Power Supply | 220 V, single-phase, 10 A, 50/60 Hz |
| Host Dimensions/Weight | ~300 × 400 × 780 mm / ~40 kg |
| Control Box Dimensions/Weight | ~330 × 350 × 180 mm / ~10 kg |
| Standards Compliance | JIS K6734, K6745, K6773, K6924-2, ASTM D1043, ISO 458 |
| Brand | Yunfan |
|---|---|
| Origin | Tianjin, China |
| Model | NF-Lab Needleless Electrospinning System |
| Application | Laboratory-scale nanofiber fabrication for R&D in polymer science, biomaterials, and filtration media development |
| Design Type | Rotating drum–based needleless electrospinning platform |
| Key Advantage | Eliminates multi-needle clogging, improves fiber uniformity, suppresses “bead-on-string” and “lamp filament” artifacts |
| Brand | Yunfan |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | YF-01-R |
| Pricing | Available Upon Request |
| Fiber Diameter Range | 25.55–180 µm |
| Brand | Yunfan / YFSP |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YFSP-T |
| Pricing | Available Upon Request |
| Brand | Zehntner |
|---|---|
| Model | ZRM 6014 |
| Origin | Switzerland |
| Measurement Principle | CIE Standard Observer (V(λ))–weighted luminance ratio under defined geometry |
| Compliance | EN 1436, ASTM E1710, ASTM E2177, ASTM E2302 |
| Measurement Modes | RL (Retroreflection Coefficient) and QD (Diffuse Reflection Coefficient) |
| Illumination Angle Options | 1.24° (EN), 88.76° (ASTM E1710 RL), Diffuse (QD) |
| Observation Angles | 2.29° (EN 1436), 1.05° (ASTM E1710) |
| Measuring Aperture | 52 mm × 218 mm |
| Simulated Distance | 30 m |
| RL Range | 0–4,000 mcd·m⁻²·lx⁻¹ |
| QD Range | 0–400 mcd·m⁻²·lx⁻¹ |
| Display | 5.7″ high-resolution capacitive touchscreen |
| Data Storage | 1 GB internal flash memory |
| Power Supply | Rechargeable Li-ion Mn battery (14.8 V / 6.3 Ah) |
| Operating Temperature | −10 °C to +50 °C |
| Dimensions (L×W×H) | 658 × 190 × 408 mm |
| Weight | 7.5 kg |
| Integrated Sensors | GPS module, digital compass, electronic inclinometer, real-time ambient humidity & timestamp |
| Connectivity | Bluetooth 4.2, USB 2.0, CSV/Excel export support |
| Environmental Certification | RoHS-compliant, lead-free |
| Key | Brand: Zhonghang Dingli |
|---|---|
| Origin | Beijing, China |
| Model | ZHDL-200 Series |
| Motor Power | 3.0 kW (Panasonic) |
| Speed Range | 0.1–120 rpm |
| Torque Range | 0–200 N·m (rated 300 N·m) |
| Torque Accuracy | ±0.3% F.S. |
| Melt Pressure Range | 0.1–100 MPa |
| Pressure Accuracy | ±0.3% F.S. |
| Temp Control Range | Ambient to 350 °C (5-zone control, 6-point measurement) |
| Temp Accuracy | ±0.1 °C |
| Data Acquisition Rate | 50 Hz |
| Mixer Volume | 60 mL |
| Rotor Type | Roller (Banbury/Cam/Delta optional) |
| Heating Power | 2.1 kW (3×700 W) |
| Voltage | AC 380 V, 7.5 kW |
| Brand | Zhonghang Shidai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | ZLD-600V |
| Price Range | USD 2,100 – 5,600 |
| Brand | Zhonghangshidai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | MFI-400H |
| Test Method | Volumetric (Method B per ISO 1133) |
| Type | Standard-Function Melt Flow Indexer |
| Temperature Range | Ambient to 300 °C (extended range: 80–400 °C) |
| Temperature Accuracy | ±0.1 °C |
| Melt Flow Rate Range | 0.1–100 g/10 min |
| Load Selection | Motorized, Programmable via Dual-Thread Lead Screw |
| Displacement Measurement | High-Precision Optical Encoder (ISO 1133 Method B) |
| Compliance | GB/T 3682–2018, ISO 1133:2005, ASTM D1238 |
| Brand | Zhonghangshidai |
|---|---|
| Model | ZST-121 |
| Standard Compliance | GB/T 31838.2–2019, GB/T 31838.3–2019 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Accuracy | ±2% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~5 kg |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Key | Brand: Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | MFI-1221 |
| Test Method | Mass Flow Rate (MFR) & Volume Flow Rate (MVR) |
| Temperature Range | 100–450 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Recovery Time | ≤2 min after charge |
| Die Dimensions | 2.095 mm ±0.005 mm ID, 8.000 mm ±0.025 mm length |
| Barrel ID | 9.550 mm ±0.007 mm |
| Piston Displacement Resolution | 0.002 mm |
| Piston Accuracy | ±0.02 mm |
| Load Application | Manual |
| Display | 5-inch HD color TFT touchscreen (bilingual: EN/CN) |
| Power Supply | 220 VAC ±10%, 50 Hz, 0.5 kVA |
| Weight | ~25 kg (main unit), ~25 kg (accessories) |
| Compliance | GB/T 3682–2018, ASTM D1238, ISO 1133:2005, BS 2782 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XRW-300A3 |
| Temperature Range | 50–300 °C |
| Heating Rate Options | 120 °C/h and 50 °C/h |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Specimen Stations | 3 |
| Deflection Measurement | Digital micrometer with 0.001 mm resolution and 0–13 mm range |
| Support Span Options | 64 mm and 100 mm (ASTM-compliant adjustable) |
| Heating Medium | Methyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt) |
| Control Method | Fuzzy PID + PWM modulation |
| Data Acquisition | 7 samples/sec, 4–8 channels per sample |
| Human-Machine Interface | 7-inch capacitive color touchscreen with bilingual (EN/CN) OS |
| Compliance Standards | GB/T 1633, GB/T 1634.1–1634.3, GB/T 8802, ISO 2507, ISO 75, ISO 306, ASTM D1525, ASTM D648 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XRW-300A6 |
| Temperature Range | 50–300 °C |
| Heating Rates | 120 °C/h or 50 °C/h (user-selectable) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Deflection Measurement | Digital micrometer with 0.001 mm resolution, 0–13 mm range |
| Specimen Span | 64 mm or 100 mm (ASTM-compliant adjustable) |
| Sample Stations | 6 independent test positions |
| Heating Medium | Methyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt, supplied separately) |
| Control Algorithm | Fuzzy PID with PWM output |
| Data Acquisition Rate | 7 samples/second per channel (4–8 channels simultaneously) |
| Human-Machine Interface | 7-inch capacitive color touchscreen, bilingual (English/Chinese) OS |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | Zhonglu |
|---|---|
| Model | XRW-300B4 |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Application | Heat deflection temperature (HDT) and Vicat softening temperature (VST) testing of thermoplastics, thermosets, fiber-reinforced composites, laminates, and electrical insulating materials |
| Standards Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648 |
| Temperature Control Range | Ambient to 300 °C |
| Max. Temp. Deviation | ±0.5 °C |
| Heating Rates | 50 °C/h or 120 °C/h (adjustable between 50–120 °C/h) |
| No. of Test Stations | 4 |
| Deflection Measurement Range | 0–10 mm |
| Deflection Accuracy | ±0.005 mm |
| Resolution | 0.001 mm |
| Span Lengths | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | <0.005 /100 °C |
| Temperature Sensor Type | High-stability platinum RTD |
| Displacement Sensor | Optical-grating digital micrometer |
| Control Method | PC-based software with real-time curve display and automated reporting |
| Safety Protections | Dual hardware/software temperature limit switches (30 A Korean thermal cutoff), end-of-test auto-halt, administrator password lockout |
| Heating Power | 4000 W |
| Heat Transfer Medium | Methyl silicone oil or transformer oil |
| Cooling | Natural convection above 150 °C |
| Brand | Zhonglu |
|---|---|
| Model | XRW-300C6 |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Control Interface | 7-inch touchscreen + PC software |
| Test Frames | 6 |
| Temperature Range | Ambient to 300 °C |
| Max Temp Error | ±0.5 °C |
| Heating Rates | 50 °C/h, 120 °C/h, or user-defined between 50–120 °C/h |
| Deformation Range | 0–10 mm |
| Deformation Accuracy | ±0.005 mm |
| Resolution | 0.001 mm |
| Span Lengths | 64 mm and 100 mm |
| Thermal Medium | Methyl silicone oil or transformer oil (user-supplied) |
| Cooling | Natural cooling above 150 °C |
| Safety Protections | Dual hardware/software temperature limit switches, automatic test termination, administrator password lock |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648 |
| Brand | ZRTB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZB-603 |
| Price | USD 1,250 (FOB Jiangsu) |
