Sample Prep/Digestion Equipment
Filter
Showing 121–150 of 258 results
| Key | Brand: EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Nova HT1000 |
| Heating Plate Temperature Range | Up to 300 °C |
| Maximum Applied Force | 200 kN (20 tonf) |
| Max. Platen Size | 300 × 300 mm |
| Positional Speed Control Resolution | 0.01 mm/s |
| Platen Material | SKD11/SKD61 Chromium-Molybdenum Alloy with Mirror-Finish Chrome Plating |
| Cooling System | Pressure-Controlled Automatic Water-Cooling Circuit |
| Control Mode | Manual & Programmable Multi-Stage Velocity Profile |
| Brand | EWIN-TECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Nova HT200 |
| Pricing | Available Upon Request |
| Brand | EXAKT |
|---|---|
| Origin | Germany |
| Model | E311CL |
| Instrument Type | Precision Diamond Band Saw |
| Maximum Cutting Dimensions (L×W×H) | 380 × 175 × 160 mm |
| Minimum Slice Thickness | 0.5–1.0 mm |
| Worktable Size | 400 × 400 mm |
| Max. Sample Size | 380 × 380 × 175 mm |
| Blade Speed | 10–800 m/min |
| Cutting Force Range | 1.0–8.0 N |
| Positioning Accuracy | ±0.02 mm |
| Flatness Tolerance (Load-Induced Deflection) | ±0.05 mm |
| Diamond Band Thickness | 0.3 mm |
| Cooling | Recirculating Water System |
| Dimensions (W×D×H) | 1000 × 1350 × 850 mm |
| Weight | 150 kg |
| Power Supply | 220 V, 50/60 Hz |
| Optional Accessories | Point-Contact (CP) Cutting Module, T-Slot Worktable, Mechanical Sample Clamping Fixtures |
| Brand | Fischione |
|---|---|
| Origin | USA |
| Model | 1051 |
| Maximum Sample Diameter | 3 mm |
| Tilting Angle Range | −15° to +10° |
| Ion Beam Energy | 100 eV – 10 keV |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Digestor™ 2508 and Digestor™ 2520 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Temperature Range | Ambient to 440 °C |
| Temperature Stability | ±1 °C at 400 °C |
| Temperature Accuracy | ±1 °C across full range |
| Max. Tube Capacity | 8 (Digestor™ 2508) / 20 (Digestor™ 2520) tubes per batch |
| Tube Volumes Supported | 100 mL, 250 mL, 400 mL |
| Heating Time (20 °C → 400 °C) | ~35 min (2508), ~40 min (2520) |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 1100 W (2508), 2300 W (2520) |
| Dimensions (W×D×H) | 300×440×140 mm (2508), 300×600×140 mm (2520) |
| Net Weight | 10 kg (2508), 18 kg (2520) |
| Exhaust Flow Rate | 3–5 L/min (initial 5 min), then 1 L/min (2508) |
| Application Memory | Up to 254 methods (127 FOSS-standard + 127 user-defined) |
| Max. Steps per Method | 23 (including ramp, hold, cool-down, wash cycles) |
| Communication Interface | Bidirectional PC interface compliant with GLP traceability requirements |
| Optional Accessories | Integrated fume extraction duct, external scrubber unit, programmable peristaltic wash system |
| Brand | GP |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ED20 |
| Instrument Type | Electric Heating Acid Evaporation System |
| Heating Plate Compatibility | Designed for use atop standard laboratory electric hot plates |
| Sample Capacity | 20 positions |
| Well Diameter | 40 mm (custom diameters available) |
| Working Surface Dimensions | 280 × 300 mm |
| Heating Block Material Options | Anodized Aluminum or Graphite |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Type | Graphite Block Digestion System |
| Model | ED20G |
| Heating Method | Uniform Surrounding Graphite Heating |
| Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±1 °C (±0.2 °C with PID control loop) |
| Max Power | 3.6 kW |
| Number of Digestion Positions | 20 |
| Compliance | EPA Method-Compatible |
| Software Interface | RS-232/USB Digital Serial Port for PC Integration and LIMS Connectivity |
| Sample Uniformity | ±1.5 °C across all 20 positions (ambient–210 °C) |
| Brand | DingHong |
|---|---|
| Origin | Jiangsu, China |
| Model | GU-AI9000 |
| Ion Beam Energy | 0–10 keV |
| Tilting Range | 0–360° (continuous rotation) |
| Maximum Sample Dimensions | <25 × 25 × 20 mm |
| Beam Spot Size | ≥Φ500 nm (nominal thin area diameter) |
| Vacuum System | Integrated diaphragm pump + turbo-molecular pump |
| Cooling Options | Peltier-cooled stage (–30 °C) or optional liquid nitrogen cryo-stage |
| Brand | HACH |
|---|---|
| Origin | Shanghai, China |
| Model | HT200S |
| Digestion Positions | 12 × 20 mm |
| Temperature Range | 40–170 °C |
| Temperature Accuracy | ±1 °C |
| Heating Principle | Electric Resistance Heating |
| Cooling | Integrated Active Air-Cooling System |
| Programmable Methods | 3 Predefined (100 °C, 148 °C, HT) + 9 User-Defined |
| Display | Dual-Line LCD |
| Power Supply | 230 V ±5%/−15%, 50 Hz, 1300 VA |
| Safety Certifications | CE, GS, cTUVus |
| Dimensions (W×D×H) | 330 × 300 × 430 mm |
| Weight | 12 kg |
| Operating Environment | 10–45 °C, ≤90% RH |
| Compliance | EN ISO 6060 (COD), EPA Method 410.4, ASTM D1252 |
| Brand | Haiguang Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HGD Series |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automated |
| Digestion Positions | Configurable up to 48 samples (standard configuration) |
| Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Heating Principle | Uniform graphite block conduction with PID-controlled dual-zone heating |
| Reagent Dispensing Channels | Up to 6 independent corrosion-resistant reagent lines (HNO₃, HCl, HF, H₂O₂, etc.) |
| Brand | TOP (Tianjin) |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HF-2A |
| Instrument Type | Manual Pellet Press |
| Compatible Die Diameter | 13 mm |
| Maximum Pressure Capacity | 15 metric tons |
| Required Accessory | HF-6 Tablet Holder Insert |
| Brand | Top Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HF-2D |
| Instrument Type | Manual Pellet Press |
| Maximum Pressure Capacity | 15 t |
| Die Cavity Diameter | Φ20 mm |
| Ejection Mechanism | Integrated Manual Demolding System |
| Pricing | USD 198 (FOB Tianjin) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C-MAG HP 10 |
| Heating Power | 1500 W |
| Max. Heating Temperature | 500 °C |
| Temperature Uniformity | Compatible with ETS-D5 Contact Electronic Thermometer |
| Plate Dimensions | 260 × 260 mm |
| Display Type | LED |
| Temperature Control Accuracy | ±10 K |
| External Temperature Sensor Interface | ETS-D5 |
| Max. Vessel Capacity | 15 L |
| Heating Rate | 5 K/min |
| Work Surface Material | Ceramic |
| Housing Protection Rating | IP21 |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % |
| Voltage | 230 / 120 / 100 V |
| Frequency | 50/60 Hz |
| Net Weight | 6 kg |
| Overall Dimensions (W × H × D) | 300 × 105 × 415 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Model | C-MAG HP 4 |
| Heating Power | 250 W |
| Temperature Range | 50–500 °C |
| Temperature Uniformity | ±10 K |
| Heating Surface Dimensions | 100 × 100 mm |
| Display Type | LED |
| Protection Class | IP21 |
| Input Voltage | 230 V, 50/60 Hz |
| Weight | 3 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C-MAG HP 7 |
| Heating Power | 1000 W |
| Max. Heating Temperature | 50–500 °C |
| Plate Dimensions | 180 × 180 mm |
| Operating Ambient | 5–40 °C, ≤80 % RH |
| Input Voltage | 230 / 120 / 100 V, 50/60 Hz |
| Weight | 5 kg |
| Plate Material | Seamless Ceramic |
| Max. Vessel Capacity | 10 L |
| Heating Rate | 5 K/min |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C-MAG HP4 |
| Heating Power | 250 W |
| Temperature Range | 50–500 °C |
| Temperature Control Accuracy | ±10 K |
| Heating Plate Material | Ceramic |
| Plate Dimensions | 100 × 100 mm |
| Device Dimensions (W × D × H) | 150 × 105 × 260 mm |
| Weight | 3 kg |
| Protection Rating | IP21 |
| Voltage | 230 V, 50/60 Hz |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH (DIN EN 60529) |
| Brand | JIA XIN HAI |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JYP-24-D |
| Price | USD 820 (FOB Tianjin) |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Circular Split Die, 61–70 mm Diameter |
| Price | USD 700 (FOB Tianjin) |
| Brand | Jiaxinhai |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JPT-10 |
| Price | USD 850 (FOB Tianjin) |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PCD-40S |
| Instrument Type | Semi-Automatic Pellet Press |
| Force Capacity | 40 Ton (392 kN) |
| Drive Method | Electric Motor with Hydraulic Amplification |
| Control Mode | Digital Panel with Preset Pressure & Hold Time |
| Brand | Jing Tuo Instrument |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PP-20S |
| Instrument Type | Fully Automatic Pellet Press |
| Force Capacity | 20 Ton (196 kN) |
| Control System | Integrated Programmable Logic Controller (PLC) with Touchscreen HMI |
| Compression Mode | Hydraulic + Servo-Motor Assisted Dual-Drive |
| Maximum Die Cavity Diameter | 30 mm (standard) |
| Repeatability | ≤ ±0.5% of set pressure |
| Cycle Time | Adjustable from 15–60 s per pellet |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTRJ-4D |
| Temperature Control Accuracy | ±0.5°C |
| Operating Temperature Range | 30–45°C |
| Capacity | 4 sample positions |
| Power Supply | 220 V / 50 Hz |
| Heating Power | ≥2.0 kW |
| Circulating Pump Flow Rate | 15 L/min |
| Display | Digital LCD with time/temperature readout |
| Timer Range | 1–999 minutes |
| Safety Features | Low-water-level alarm, over-temperature cutoff, power-loss memory retention |
| Construction | Polyurethane-insulated chamber, stainless steel water bath, medical-grade impermeable barrier membrane |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTRJ-4D |
| Temperature Control Accuracy | ±0.5 °C |
| Operating Temperature Range | 30–45 °C |
| Sample Capacity | 4–12 positions |
| Power Supply | 220 V / 50 Hz |
| Heating Power | ≥2.0 kW |
| Circulating Pump Flow Rate | 15 L/min |
| Display | 7-inch touchscreen with real-time water temperature and remaining thaw time |
| Thawing Time | 10–20 min (for two 100–200 mL plasma bags, frozen at −20 °C) |
| Thawing Method | Dry-contact water-bath (membrane-isolated, non-immersive) |
| Agitation Mode | Programmable orbital oscillation |
| Compliance | Not classified as medical device per FDA/MDR |
| Brand | KaiGe |
|---|---|
| Origin | Germany |
| Model | MAK / MOK |
| Type | Manual/Electric Linear Notching Machine for Charpy/Izod Impact Test Specimens |
| Compliance | ASTM E23, ISO 148-1, ISO 180, DIN 53438, EN ISO 179-1 |
| Max Specimen Height | 30 mm |
| Tool Positioning Tolerance | < 0.01 mm |
| Feed Resolution | 0.001 mm (selectable) |
| MAK Cutting Speed | ~0.3 m/s |
| MOK Cutting Speed | up to 20 m/min |
| Power Supply | 230 V / 50 Hz |
| MOK Power Consumption | 0.4 kVA |
| Dimensions (W×H×D, mm) | MAK: 470 × 215 × 220 |
| MOK | 470 × 540 × 470 |
| Weight | MAK: 16 kg |
| MOK | 43 kg |
| Max Simultaneous Specimens | 7 |
| Safety | Integrated Polycarbonate Shield with Interlocked Safety Switch (MOK only) |
| Tool System | Interchangeable Carbide-Tipped Notching Cutters (V-notch: 45° ± 0.5°, root radius 0.25 mm ± 0.025 mm |
| U-notch | 1 mm ± 0.05 mm radius) |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AKM |
| Quotation | Upon Request |
| Blade Travel Speed | 0–800 mm/s |
| Stroke Length | 208 mm |
| Notch Type | V-Notch |
| Feed Rate (Notching) | 0.01–0.3 mm/rev |
| (Fine Adjustment) | 0.01–0.1 mm/rev |
| Saw Cutting Speed | 0.3–1 m/min |
| Saw Rotational Speed | 1000–2000 rpm |
| Notch Depth (Z-axis) | 0.01–0.25 mm |
| Machining Length | ~200 mm |
| Width | 1200 mm |
| Height | 700 mm |
| Depth | 540 mm |
| Weight | 150 kg |
| Power Consumption | ~1 kW |
| Supply Voltage/Frequency | 230 V / 110 V, 50/60 Hz |
| Brand | Karg |
|---|---|
| Origin | Germany |
| Model | MPS 75 / MPS 150 |
| Max Punching Force | 7,500 N (MPS 75) / 15,000 N (MPS 150) |
| Max Stroke | 40 mm |
| Table Dimensions | 250 × 150 mm |
| Weight | 50 kg |
| Footprint (W×D) | 250 × 240 mm (MPS 75) / 250 × 300 mm (MPS 150) |
| Operation | Lever-Actuated or Pneumatic Option Available |
| Compliance | Configurable for ISO 179, ISO 180, ASTM D6110, ASTM D5041, ISO 13802 Notch Geometries |
| Brand | Katanax |
|---|---|
| Origin | Canada |
| Model | X300 |
| Dimensions (L×W×D) | 51×48×63 cm |
| Temperature Control Accuracy | ±1°C |
| Operating Temperature Range | 50–1200°C |
| Sample Throughput | 7–20 samples/hour |
| Brand | Katanax |
|---|---|
| Origin | Canada |
| Model | X600 |
| Dimensions (L×W×D) | 56 × 105 × 69 cm |
| Temperature Control Accuracy | ±1°C |
| Operating Temperature Range | 20–1200°C |
| Sample Capacity | 6 samples per run |
| Brand | KB |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KYXQ-5000 |
| Instrument Type | Hot Mounting Press |
| Heating Power | 4 kW |
| Temperature Range | 0–200 °C (factory preset: 160 °C) |
| Pressure Holding Time | 0–99 min (factory preset: 1 min) |
| Cooling Duration | 0–99 min (factory preset: 0.5 min) |
| Power Supply | 220 V, 50 Hz |
| Total Power Consumption | 2.2 kW |
| Dimensions (W×D×H) | 760 × 580 × 550 mm |
| Weight | 95 kg |
| Standard Mold Diameter | φ30 mm (optional: φ22 mm, φ45 mm |
| Sample Capacity | 4 specimens per cycle (2 stations × 2 molds) |
| Process Memory | >100 user-defined mounting protocols |
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | HXQ-50 |
| Instrument Type | Hot Mounting Press |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1200 W |
| Temperature Range | 30–180 °C |
| Pressure Range | 10–2000 kPa |
| Holding Time | 1–900 min |
| Cooling Method | Water-cooled (auto-stop at ≤50 °C) |
| Mold Diameters | Ø25 / Ø30 / Ø40 / Ø50 mm |
| Max. Samples per Cycle | 2 |
| Dimensions (W×D×H) | 600 × 490 × 550 mm |
| Weight | 100 kg |
| Ambient Requirements | ≤1000 m altitude, 10–40 °C ambient, 45–65 %RH |
| Water Connection | Required (inlet & drain) |
| Ventilation | Mandatory |