Sample Preparation Workstation
Filter
Showing 31–55 of 55 results
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Model | EXPEC 550 |
| Extraction Vessel Capacity | 10–60 mL |
| Operating Pressure Range | Up to 20 MPa |
| Temperature Range | Ambient to 200 °C |
| Cycle Time per Sample | 15–30 min |
| Solvent Consumption | Reduced by ≥70% vs. Soxhlet |
| Safety Compliance | Integrated Leak Detection, Over-Pressure & Over-Temperature Interlocks, Method Validation Alert System |
| Heating Jacket Surface Temp | <50 °C |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 560 |
| Throughput | Up to 36 samples per batch |
| Drive Type | Brushless DC motor with variable-speed control |
| Homogenization Motion | Vertical reciprocating + rotational motion |
| Cleaning Modes | Aqueous rinse, organic solvent rinse, ultrasonic-assisted cleaning |
| Enclosure | Full-integrated transparent safety door with interlock |
| Safety Compliance | CE-marked per EN 61000-6-2/6-4 and EN 61000-3-2/3-3 |
| Software Interface | Touchscreen HMI with method storage, real-time status monitoring, and fault logging |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Model | EXPEC 570 |
| Configuration Options | 2-, 6-, 8-channel & PFA-dedicated variants |
| Origin | Zhejiang, China |
| System Architecture | Integrated touchscreen-controlled platform with internal waste segregation |
| Sample Throughput | Batch-mode processing for up to 8 samples simultaneously (model-dependent) |
| Flow Control | Precision syringe-pump-driven elution with column-seal plug design |
| Compatibility | Standard 1 mL–6 mL SPE cartridges (C18, HLB, Florisil, SAX, SCX, PFA-lined, etc.) |
| Optional Modules | Large-volume aqueous sample enrichment (>500 mL), custom cartridge adapters, GLP-compliant audit trail upgrade |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 750 |
| Flow Rate Range | 0.5–600 mL/min |
| Channel Capacity | 6 parallel channels |
| Operation Modes | Fully automated activation, sample loading, washing, and elution with programmable sequence editing |
| Sample Processing Time | 10–20 min per batch |
| Compatibility | Integrated interface for AFS, ICP-OES, and ICP-MS instrumentation |
| Column Type | Pressure-rated separation column with closed-loop fluidic control |
| Precision Feature | Automatic final volume adjustment (auto-dilution/evaporation compensation) |
| Regulatory Context | Designed to support GLP-compliant workflows and traceable sample preparation under ISO/IEC 17025 laboratory accreditation requirements |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 760 |
| Balance Options | 0.01 mg (10 µg) or 0.1 mg resolution |
| Anti-static Ionizer | Integrated dual-nozzle air ionization system |
| Robotic Arm | 4-axis articulated robot with ±0.05 mm repeatability |
| Vibration Isolation | Triple-stage passive damping platform |
| Weighing Enclosure Control | Motorized draft shield door actuation synchronized with weighing cycle |
| Sample Tube Handling | Barcode-scanned vial identification, automated cap removal/placement in dedicated sterile zone |
| Data Output | CSV/Excel export, audit-trail-enabled database logging compliant with GLP requirements |
| Compliance | Designed to support ISO/IEC 17025 workflows and FDA 21 CFR Part 11–ready data integrity architecture |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 780 |
| Heating Block Material | High-Purity Graphite |
| Automation Level | Full Unattended Operation |
| Acid Resistance | PTFE/PFA-Wetted Components Compatible with HNO₃, HCl, HF, and HClO₄ |
| Temperature Control | PID-Controlled Distributed Heating |
| Temperature Range | Ambient to 230 °C |
| Sample Capacity | Up to 48 Positions (Configurable) |
| Acid Addition | Six Independent Peristaltic Pumps + Precision Syringe Pump for Spiking |
| Lid Handling | Motorized Lid Sealing/Unsealing with Condensation-Optimized Design |
| Volume Accuracy | <1% RSD at 50 mL (Ultrasonic Level Sensing) |
| Volume Range | 5–50 mL |
| Mixing Method | Pneumatic Bubble Agitation |
| Sample Transfer | Integrated Robotic Arm to Autosampler Tray |
| Exhaust System | Dedicated Acid-Fume Extraction with Corrosion-Resistant Ducting |
| Compliance | Designed for GLP/GMP Environments |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 790F |
| Maximum Operating Temperature | 300 °C |
| Maximum Operating Pressure | 20 MPa |
| Safety Vessel Rating | 30 MPa |
| Digestion Cavity | Single-zone, uniform temperature/pressure |
| Sample Capacity | Up to 96 samples per batch (configurable rotor: 6/8/18/24 positions) |
| Acid Volume Range | 2–3 mL per sample |
| Final Volume Accuracy | <1% RSD at 50 mL (5–50 mL range) |
| Reagent Delivery | PTFE-lined peristaltic pumps & precision syringe pump |
| Filtration | Auto-replacement disposable filter cartridges |
| Interface | ICP-OES/ICP-MS direct coupling support |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EXPEC 790S |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pre 3900 |
| Pricing | Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pre 4000 |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pre 4100 |
| Pricing | Available Upon Request |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JT-GHX-DC |
| Light Source Compatibility | Mercury, Xenon, and Metal Halide Lamps (0–1000 W for Hg/Xe |
| Reaction Vessel Options | Quartz tubes (30 mL, 50 mL) or custom sizes |
| Sample Capacity | 8-position magnetic stirring (configurable to 6 or 12) |
| Cooling System | Dual-layer quartz cold finger with external recirculating chiller (cooling capacity >1000 W |
| temp range | −5 °C to 100 °C) |
| Safety | Overtemperature cutoff, radiation-shielded dark chamber with observation window, high-voltage lamp housing, integrated power sockets for lamps and stirrers |
| Brand | JTONE |
|---|---|
| Origin | Zhejiang, China |
| Model | JTZL-6C |
| Heating Method | 6-channel Far-Infrared Ceramic Heater (≤800 W per channel) |
| Distillation Capacity | 6 samples simultaneously |
| Distillation Rate | 12 mL/min |
| Temperature Range | Ambient to 320 °C |
| Endpoint Control | Dual-mode (gravimetric ±2 mL accuracy or timer 0–999 min) |
| Cooling System | Built-in air-cooled recirculating water unit |
| Display | 7-inch capacitive touch LCD |
| Single-Channel Temperature Control | Yes |
| Anti-Suck-Back | Electromagnetic vacuum valve |
| Power Supply | 220 V / 50 Hz |
| Flask Compatibility | Six 500 mL or 250 mL round-bottom flasks |
| Warm-up Time | 5–20 min |
| Brand | NAYO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | A96 |
| Pricing | Available Upon Request |
| Brand | Pribolab |
|---|---|
| Model | MP2000S |
| Origin | Shandong, China |
| Construction | Aluminum oxide sample tray, food-grade stainless steel homogenizing probe |
| Dimensions (H×W×D) | 550 × 360 × 630 mm |
| Weight | 33 kg |
| Standard Tray Capacity | 6-position (compatible with 100 mL and 300 mL sample bottles) |
| Optional Trays | 10-position and custom configurations |
| Probe Speed Range | 0–25,000 rpm (10-step BLDC motor control) |
| Positioning Accuracy | < 0.5 mm (mechanical arm), repeatability < 0.1 mm |
| Cleaning System | Multi-solvent rinse + ultrasonic cleaning + reverse-rotation probe cleaning |
| Control Interface | Touchscreen with editable, savable homogenization methods |
| Homogenization Motion | Vertical amplitude adjustment during operation |
| Enclosure | Powder-coated steel housing with ergonomic 3D panel design |
| Brand | SOTAX |
|---|---|
| Origin | Switzerland |
| Model | TPW |
| Application Scope | Solid Oral Dosage Forms, Granulation Intermediates, Semi-solids (e.g., Toothpaste, Lipstick) |
| Sample Throughput | 100–200 samples per run |
| Solvent Volume Range | 20–100 mL or 50–520 mL |
| Integrated Unit Functions | Automated Weighing, High-Shear Homogenization, Filtration, Dilution, Data Logging & Storage |
| Software | DoE-Enabled Method Development Suite with Cross-Site Transfer Capability |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Technobis |
|---|---|
| Origin | Netherlands |
| Model | Crystal16 |
| Reactor Volume | 0.5–1 mL per channel |
| Number of Channels | 16 |
| Temperature Control Zones | 4 independent modules |
| Stirring Modes | top-mounted overhead stirrer and bottom magnetic stirring |
| In-situ Turbidity Monitoring | non-invasive, channel-specific optical turbidity detection |
| Software | integrated control and analysis suite compliant with GLP data integrity principles |
| Regulatory Alignment | supports 21 CFR Part 11 audit trail requirements for electronic records |
| Brand | Technobis |
|---|---|
| Origin | Netherlands |
| Model | CrystalBreeder |
| Reaction Volume per Vial | 0.05–0.2 mL |
| Total Channels | 32 (8 modules × 4 vials) |
| Temperature Control | Programmable, ±0.1 °C accuracy |
| Stirring | Top-mounted paddle and bottom-mounted magnetic stirring (interchangeable) |
| In-situ Monitoring | Non-invasive turbidity detection per channel |
| Optional Modes | Vapor diffusion, evaporation crystallization |
| Compliance | Designed for GLP-compliant early-phase pharmaceutical development |
| Brand | Technobis |
|---|---|
| Origin | Netherlands |
| Model | Crystalline |
| Configuration Options | Crystalline SE (turbidity), Crystalline PV (in-situ particle size), Crystalline RR (in-situ Raman) |
| Reactor Count | 8 independent channels |
| Reaction Volume per Channel | 2.5–5 mL |
| Stirring | Top-mounted magnetic or mechanical stirring |
| Integration | Modular benchtop platform for process analytical technology (PAT)-enabled crystallization development |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ADP5 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | APLE-3500 |
| Extraction Pressure | Up to 20 MPa |
| Temperature Range | Ambient to 200 °C |
| Pump Flow Rate | 100 mL/min |
| Extraction Cell Volumes | 1, 5, 11, 22, 34, 66, and 100 mL |
| Cycle Time per Sample | <20 min |
| Solvent Consumption (typical) | ≥1.5 mL per 1 g sample |
| Compliance | EPA Method 3545, HJ 782–2016, HJ 783–2016 |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | APLE-5000 |
| Extraction Mode | Parallel & Sequential Dual-Channel |
| Sample Capacity | 24 positions (unattended) |
| Solvent Compatibility | Common organic solvents (e.g., acetone, dichloromethane, hexane, methanol, ethyl acetate) |
| Operating Pressure | Up to 20 MPa |
| Temperature Range | Ambient to 200 °C |
| Extraction Cell Options | 1, 5, 10, 22, 34, 66, and 100 mL |
| Collection Precision | ±0.1 mL |
| Control Interface | Windows-based software with Wi-Fi remote access |
| Data Integrity | Audit trail, user authentication, method versioning, and electronic signature support compliant with GLP/GMP requirements |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APNE-12 |
| Pricing | Available Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | FSI-12 |
| Pricing | Upon Request |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Model | FSI-12 |
| Application Standard | GBZ/T 192.4–2007 |
| Automation Level | Unattended Operation |
| Sample Throughput | 12-position high-throughput carousel |
| Reagent Handling | Automated pyrophosphoric acid dispensing |
| Digestion Control | Dual-sensor independent channel temperature regulation (±0.5 °C) |
| Stirring | Adjustable speed per channel |
| Filtration | Optimized funnel geometry with real-time liquid-level monitoring |
| Compliance | Designed for occupational hygiene laboratories requiring traceable, auditable sample preparation per Chinese national standards |