| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP 4500 System |
| Category | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Regulatory Status | Research-Use-Only (RUO), Not FDA-cleared or CE-IVD marked |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX 7500+ System |
| Instrument Type | Triple Quadrupole (Tandem Quadrupole, QqQ) |
| Application Scope | Universal LC-MS/MS Analysis |
| MRM Transition Rate | 800 transitions/sec |
| Vacuum System Compatibility | Dry Pump Compatible |
| Regulatory Alignment | Designed for GLP/GMP-compliant laboratories |
| Software Platform | SCIEX OS |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | QTRAP® 6500+ |
| Instrument Type | Hybrid Triple Quadrupole/Linear Ion Trap |
| Mass Range | Up to m/z 2,000 |
| Sensitivity | >10× improvement in detection sensitivity |
| Resolution | Unit mass resolution |
| Accurate Mass Capability | Not applicable (non-high-resolution platform) |
| Ionization Sources | IonDrive Turbo V, TurboIonSpray®, APCI, DuoSpray™, NanoSpray® III, SelexION®+ DMS, LDTD, LESA Clarity, Digital PicoView, NanoSource |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Triple Quad 6500+ |
| Instrument Type | Tandem Quadrupole (QqQ) LC-MS/MS System |
| Mass Range | 2000 m/z |
| Dynamic Range | 6 orders of magnitude |
| Polarity Switching Time | 5 ms |
| Scan Speed | 12,000 Da/sec |
| Ion Sources | IonDrive Turbo V, TurboIonSpray, APCI, DuoSpray, PhotoSpray, NanoSpray III, LDTD, LESA Clarity, Digital PicoView |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | P/ACE™ MDQ Plus |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis |
| Cooling Method | Liquid Cooling |
| Detectors | UV, Laser-Induced Fluorescence (LIF), Diode Array Detector (DAD) |
| Injection Mode | Electrokinetic |
| Pressure Range | 5–100 psi |
| Temperature Control | Liquid-Cooled Capillary Thermostat |
| Vendor Type | Authorized Distributor |
| Import Status | Imported |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX BioPhase™ 8800 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Channel Capacity | 8 parallel capillaries |
| Detection Modes | UV-Vis and Laser-Induced Fluorescence (LIF) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| Application Focus | Biopharmaceutical characterization (mAb, bispecifics, ADCs, gene therapy vectors) |
| Sensitivity | ≤1 µg/mL (CE-SDS), linear dynamic range >4 orders of magnitude (R² > 0.995) |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Triple Quad™ 5500+ System – QTRAP® Ready |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Mass Range | Not Specified |
| Sensitivity | Not Specified |
| Resolution | Not Specified |
| Mass Accuracy | Not Specified |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF® 6600 |
| Instrument Type | Quadrupole Time-of-Flight (QTOF) Mass Spectrometer |
| Ion Source | Turbo V™ Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Additional Technology | SelexION® Differential Ion Mobility Spectrometry (DIMS) |
| Data Acquisition Mode | SWATH® Acquisition (Data-Independent Acquisition, DIA) |
| LC Compatibility | Analytical-, Micro-, Nano-flow LC and Capillary Electrophoresis–Electrospray Ionization (CESI) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX ZenoTOF 8600 System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Universal (Small Molecules to Intact Proteins) |
| Ion Source | OptiFlow Pro Turbo Ionization Source |
| Mass Analysis Technology | Zeno™ Trap-Enhanced TOF with High-Frequency Pulsed Injection |
| Max MS/MS Scan Rate | 858 Hz (dependent on mass range and acquisition mode) |
| Quadrupole Scanning Speed | up to 4000 Da/s |
| Fragmentation Modes | CID, EAD (Electron-Activated Dissociation) up to 50 eV in both positive and negative ion modes |
| Vacuum System | Oil-Free Dry Pumping |
| Software Platform | SCIEX OS 4.0 with Real-Time Performance Monitoring, Health Diagnostics & Auto-Tuning |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | TripleTOF™ 6600+ System |
| Category | Hybrid Quadrupole-Time-of-Flight Mass Spectrometer (Q-TOF MS) |
| Configuration | LC-MS/MS Platform for High-Resolution Accurate-Mass (HRAM) Analysis |
| Intended Use | Discovery and Quantitative Proteomics, Metabolomics, Lipidomics, and Small-Molecule Applications |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX ZenoTOF® 7600 System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Universal |
| Mass Range | >40,000 Da |
| Sensitivity Enhancement | 5–20× vs. prior-generation Q-TOF |
| Resolution | >42,000 (FWHM at m/z 1,222) |
| Mass Accuracy | <1 ppm (external calibration) |
| Pressure Range | 0–1024 bar (HPLC/UHPLC compatible) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 5500+ System |
| Application Scope | General-Purpose Quantitative and Qualitative LC-MS/MS Analysis |
| Regulatory Status | Not Registered or Filed with NMPA for Clinical Diagnostics or Therapeutic Use |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500R QTOF System |
| Application Domain | General-purpose LC-MS/MS Analysis |
| Compliance | Not registered as medical device in China |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Intabio ZT System |
| Instrument Type | Capillary Isoelectric Focusing (cIEF) System |
| Application Focus | Charge Variant Analysis of Monoclonal Antibodies (mAbs) and Therapeutic Proteins |
| pI Resolution | ≤ 0.02 units |
| pI Range Options | 7.3–9.1 (standard ampholyte range) |
| Detection | UV-Vis (280 nm), coupled with offline or online MS integration capability |
| Data Output | Deconvoluted mass spectra aligned to individual cIEF peaks |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500R QTOF |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Configuration | LC-MS/MS Platform |
| Ion Source | Turbo V™ Ion Source (N-type ion path architecture) |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration, over 24 h) |
| Resolution | ≥ 35,000 FWHM (at m/z 622) |
| Mass Range | m/z 5–2,000 |
| Dynamic Range | > 5 orders of magnitude (linear) |
| Acquisition Modes | IDA, MRMHR, SWATH® Acquisition, MSᴱ, Full Scan + MS/MS |
| Software | SCIEX OS v2.4 or later |
| Compliance | Designed for GLP/GMP environments |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | PA 800 Plus |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic/Biopharmaceutical Analysis |
| Voltage Range | 1–30 kV |
| Detection Modes | UV, Laser-Induced Fluorescence (LIF), Diode Array Detection (DAD) |
| Injection Method | Electrokinetic |
| Pressure Range | –5 to 100 psi |
| Cooling System | Liquid-Cooled Thermostatic Control |
| Operating Principle | Capillary Zone Electrophoresis (CZE), Capillary Isoelectric Focusing (cIEF), Capillary Gel Electrophoresis (CGE), Micellar Electrokinetic Chromatography (MEKC) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | C100 HT |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis |
| Voltage Range | 1–25 kV |
| Detection Modes | UV and Laser-Induced Fluorescence (LIF) |
| Injection Method | Pressure-driven |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-based Temperature Control |
| Operating Mode | Constant Current |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Model | TripleTOF® 6600+ LC-MS/MS System |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Category | Liquid Chromatography Tandem Mass Spectrometry System |
| Compliance | Designed for GLP/GMP, FDA 21 CFR Part 11–ready workflows |
| Software Platform | Analyst® TF 1.8 with SWATH® Acquisition support |
| Ion Source Flexibility | OptiFlow® Pro Micro/Nano ESI and SelexION® Differential Mobility Separation (DMS) compatible |
| Data Acquisition Mode | Data-Independent Acquisition (DIA) via SWATH® technology |
| Architecture | High-stability TOF ion optics with segmented ion entrance lens and windowed ionization control |
| Brand | SCIEX |
|---|---|
| Origin | Singapore |
| Instrument Type | Tandem Quadrupole (Triple Quad™) or QTRAP® Mass Spectrometer |
| Flow Rate Range | 1–200 µL/min |
| Ion Source | OptiFlow™ Turbo V with Integrated Column Heater (up to 90 °C) |
| Spray Technology | SteadySpray™ Probe with Smart Probe Recognition |
| LC Platform | M5 Microflow LC featuring Microfluidic Flow Control™ |
| Column Compatibility | Phenomenex MicroFlow™ Columns |
| Software | SCIEX OS with MultiQuant™ MRMPilot™ and MasterView™ |
| Regulatory Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, ISO/IEC 17025-aligned workflows |
| Sample Introduction | Auto-sampler with vial-bottom sensing and jet-wash pump |
| Hardware Interface | Tool-free, hand-tight standard fittings with audible click confirmation |
| Gradient Delivery | Dual-pump architecture supporting direct injection and trap-elute modes |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | Echo™ MS+ System |
| Configuration Options | Integrated with SCIEX Triple Quad™ 6500+ System or ZenoTOF™ 7600 System |
| Sample Introduction Method | Contactless Acoustic Droplet Ejection (ADE) |
| Throughput | Up to 1 sample per second |
| Compatibility | Standard 384-well and 1536-well microplates |
| Interface | Orthogonal Probe Ionization (OPI) Source |
| Regulatory Alignment | Designed for GLP/GMP-compliant workflows |
| Software Platform | SCIEX OS v2.4 or later |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | X500B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Configuration | Liquid Chromatography-Mass Spectrometry (LC-MS) Platform |
| Intended Use | Biopharmaceutical Characterization and Peptide Mapping |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | 6500+ System |
| Application Field | Universal |
| Mass Range (m/z) | Up to 2000 |
| MRM Scan Speed | Up to 12,000 Da/s |
| Polarity Switching Time | 5 ms |
| Linear Dynamic Range | 6 orders of magnitude |
| Ion Source | IonDrive™ Turbo V |
| Optional Technology | SelexION™+ Differential Mobility Spectrometry |
| Detection Mode | Triple Quadrupole + Linear Ion Trap (QTRAP®) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | CESI 8000 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Type | Organic Analysis |
| Detector Options | UV and Laser-Induced Fluorescence (LIF) |
| Operating Mode | Current-Controlled |
| Injection Method | Electrokinetic |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-Cooled Temperature Control |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCIEX ZenoTOF 7600+ System |
| Instrument Type | Hybrid Quadrupole-Time-of-Flight (Q-TOF) Mass Spectrometer |
| Application Scope | Broad-spectrum Proteomics, Biomarker Discovery, Translational Research, Clinical Assay Development |
| Acquisition Mode | ZT Scan DIA (Data-Independent Acquisition with Quadrupole Dimensionality), DDA, Targeted MS/MS |
| Scan Speed | Up to 640 Hz |
| Fragmentation Technology | Electron-Activated Dissociation (EAD) |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration) |
| Mass Resolution | > 35,000 FWHM (at m/z 200) |
| Dynamic Range | > 4 orders of magnitude |