Sedimentation Particle Size Analyzer
Filter
Showing all 9 results
| Brand | Brookhaven Instruments |
|---|---|
| Origin | USA |
| Model | BI-DCP / BI-XDC |
| Measurement Principle | Centrifugal & Gravitational Sedimentation |
| Repeatability | 1% |
| Accuracy | ±2% |
| Particle Size Range (BI-DCP) | 0.01–45 µm |
| Particle Size Range (BI-XDC) | 0.01–100 µm |
| Detection Method | Visible Light (BI-DCP) / X-ray (BI-XDC) |
| Sample Introduction | Layered (LIST mode) or Homogeneous (HOST mode) |
| Rotational Speed Range | 500–15,000 rpm (BI-DCP) |
| Speed Stability | ±0.01% |
| Disk Material | Standard PMMA or Corrosion-Resistant Alternative |
| Data Storage | Built-in extinction curve database (BI-DCP) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | WFA-840D / WFA-860D / WFA-840E |
| Stirring Positions | 4 / 6 / 4 |
| Speed Range (rpm) | 10–300 / 10–300 / 0–200 |
| Speed Resolution | 1 / 1 / 1 rpm |
| Speed Accuracy | ±1 / ±1 / — rpm |
| Display | LED / LED / Scale + Knob |
| Backlight | Yes / Yes / Yes |
| Timer Range | 0–99 h or 0–999 min / OFF or 0–99 h or 0–999 min / 0–30 min or Continuous |
| Power Consumption | 11 W / 19 W / 6 W |
| Brand | Fastmicro |
|---|---|
| Origin | Netherlands |
| Model | FM-PS-PFS-V02 |
| Measurement Principle | Dark-field Mie scattering |
| Measurement Range | 0.5–150 µm |
| Repeatability | ≥90% |
| Measurement Interval | ≤10 s per scan |
| Field of View (FOV) | Ø25 mm (on 50 mm replaceable substrate) |
| Environmental Operation | Ambient pressure and vacuum-compatible |
| Compliance | ISO 14644-9, ISO 14644-17 |
| Output Formats | KLARF, Excel, PDF (ISO-compliant qualification reports) |
| Software | Integrated real-time analysis with annotated imaging and 3D signal profiling |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Partica CENTRIFUGE CN-300 |
| Measurement Principle | Centrifugal Sedimentation |
| Measured Range | 10 nm – 40 µm |
| Maximum Centrifugal Force | 30,000 × g |
| Temperature Control | Integrated Peltier Cooling for Sample Cell and Rotor |
| Measurement Modes | Density Gradient Mode & Homogeneous Mode |
| Sample Volume | As low as 2 µL (undiluted) or 10 µL (diluted) |
| Compliance | IEC 61010-1:2010 / IEC 61010-2-020:2016 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Floc-tester ET 730 / ET 740 / ET 750 |
| Stirring Positions | 4 (ET 730, ET 740) or 6 (ET 750) |
| Stirring Speed Range | 10–300 rpm |
| Timer Range | 0–999 min or 0–99 h (continuous) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Sample Vessel Compatibility | 1000–1500 mL beakers (ET 740/ET 750) |
| Illuminated Rear Panel | Yes |
| Application Environment | Laboratory (ET 740/ET 750) and Field-Deployable (ET 730) |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | SediGraph III Plus |
| Measurement Principle | X-ray sedimentation |
| Measurement Range | 0.1–300 µm |
| Repeatability | < 1% RSD |
| Accuracy | < 1% error vs. NIST-traceable standards |
| Analysis Time | 3–15 minutes per sample |
| Sample Volume | 50 mL dispersion |
| Compliance | ISO 13317-3, ASTM B761, ASTM C28 (Advanced Ceramics) |
| Automation | Unattended analysis of up to 18 samples |
| Optional Integration | MasterTech Auto-sampler for process monitoring and cloud data export |
| Brand | POWEREACH |
|---|---|
| Model | JCJ04 |
| Type | Gravitational Sedimentation Particle Size Analyzer |
| Origin | Shanghai, China |
| Measurement Principle | Gravitational sedimentation (Stokes’ law-based) |
| Particle Size Range | 1–60 µm |
| Maximum Sample Mass Capacity | 0–100 g (selectable) |
| Sensitivity | 0.1 mg |
| Data Acquisition Interval | 0.5 s |
| Sample Vessel | 500 mL calibrated glass cylinder |
| Calibration Weights | 0.5 g, 10 g, 50 g, 100 g |
| Data Output | Real-time sedimentation curve, D10/D50/D90, mean diameter, particle size distribution histogram, cumulative distribution, error estimation |
| Software Functions | Auto-zero, tare, self-calibration, alarm threshold setting, curve storage/retrieval, statistical analysis, report generation & printing |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Formulaction |
|---|---|
| Origin | France |
| Model | Turbiscan TMIX |
| Measurement Range | 0.05–1000 µm |
| Repeatability | ≤1% |
| Accuracy | ≤1% |
| Measurement Interval | 20 s |
| Spatial Resolution | 40 µm |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | SEDIMAT 4-12 |
| Standard Compliance | DIN ISO 11277, ASTM D422 (optional) |
| Sample Capacity | 12 samples per run |
| Fractionation Levels | 4 (F1–F4) or 2 (ASTM F1–F2) |
| Temperature Control | Precise 25 °C water bath |
| Automation | 4-axis robotic arm (X: 1290 mm, Y: 990 mm, Z1 stirring: 790 mm, Z2 pipetting: 490 mm) |
| Dimensions (L×W×H) | 2080 × 860 × 1940 mm |
| Weight | ~400 kg |
| Power Supply | CEE 16, 16 A, 3N/PE, AC 380 V / 50 Hz |
| Pipetting Accuracy | Depth- and time-synchronized sampling per ISO-defined intervals |