Separation/Extraction Equipment
Filter
Showing 301–330 of 365 results
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Minicen |
| Instrument Type | Palm-Sized Centrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 15,596 × g |
| Max Capacity | 12 × 2 mL |
| Rotor Configuration | Fixed-angle rotor (12-position, for 1.5–2.0 mL tubes) |
| Adapters Available | For 0.2–0.4 mL and 0.5–0.6 mL microtubes |
| Dimensions (W×D×H) | 260 × 230 × 130 mm |
| Net Weight | 4 kg |
| Power Supply | 230 V / 110 V, 50–60 Hz |
| Power Consumption | 180 W |
| Noise Level | <60 dB(A) |
| Timer Range | 30 s – 999 min (1 s resolution) |
| Acceleration/Deceleration Control | Programmable stepwise (100 rpm / 100 × g increments) |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Plasma 22 |
| Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 1288 × g |
| Capacity | 8 × 9/15 mL |
| Dimensions (W×D×H) | 270 × 400 × 270 mm |
| Net Weight | 19 kg |
| Power Supply | 220–230 V / 50–60 Hz (CE156) or 110–120 V / 50–60 Hz (CE165) |
| Power Consumption | 120 W |
| Noise Level | <60 dB(A) |
| Acceleration/Deceleration Ramps | 175 programmable profiles |
| Timer Range | 1–99 min ±5 s |
| Display | LCD showing rpm, rcf, time, acceleration/deceleration status |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Unicen 21 |
| Type | Benchtop Centrifuge |
| Max. Speed | 4200 rpm |
| Max. RCF | 2938 × g |
| Max. Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 410 × 520 × 320 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz (CE 126), 110–120 V / 50–60 Hz (CE 127) |
| Power Consumption | 280 W |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Vetcen |
| Type | Benchtop Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 12,716 × g |
| Max Capacity | 6 × 1.5 mL + 6 × capillary tubes (1.5 × 75 mm) |
| Dimensions (W×D×H) | 270 × 400 × 270 mm |
| Noise Level | <60 dB(A) |
| Acceleration/Deceleration | 3-step programmable (Fast, Soft, Free) |
| Timer Range | 1–99 min (1 min resolution) |
| Control | Microprocessor-based with LED display (RPM/RCF/time) |
| Safety | Automatic lid lock, imbalance detection, over-speed protection, stainless steel chamber, autoclavable rotors & adapters |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4632 |
| Price Range | USD 68,000 – 109,000 (estimated) |
| Maximum Operating Pressure | 10,000 psi (68.9 MPa) |
| Maximum Temperature | 200 °C |
| Extraction Vessel Volume | 2 L |
| Siphon Cup Volume | 450 mL |
| Solvent Flow Cycles | 15–22 cycles/hour |
| Total Extraction Duration | Up to 6 h |
| Compliance | ASTM D2307, ASTM D3455, IEC 60851-5, UL 1446 |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Parr Supercritical Fluid Extraction and Reaction System |
| Pricing | Available Upon Request |
| Brand | PAS |
|---|---|
| Origin | Germany |
| Model | CONCEPT 96 |
| Configuration | Imported Equipment |
| Distribution Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | QSight SP50 |
| Automation Level | Fully Automated |
| Channel Configuration | Multi-Channel |
| Extraction Format | Cartridge-Based SPE |
| Solvent Delivery Architecture | High-Pressure, Flow-Controlled Solvent Distribution |
| Brand | Polytech |
|---|---|
| Model | PPM32x |
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Configuration | 16-channel positive-pressure SPE system for PFAS enrichment |
| Compliance | Fully fluorine-free wetted path per HJ 1333–2023 and DB32/T 4004–2021 |
| Sample Throughput | 16 large-volume aqueous samples (e.g., 500–2000 mL) simultaneously, or 32 small-volume samples (e.g., <50 mL) in batch mode |
| Flow Control | Independent, programmable pneumatic pressure regulation per channel (0–100 psi, ±0.5 psi repeatability) |
| Column Compatibility | Standard 1 mL, 3 mL, 6 mL, and 12 mL SPE cartridges |
| Sample Vessel Support | Integrated rack for 16 × 50-mL centrifuge tubes or 16 × 125-mL glass/HDPE bottles |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 480 × 420 × 410 mm |
| Weight | 28 kg |
| Brand | PreeKem |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TOPEX+ |
| Price Range | USD 42,000 – 70,000 |
| Microwave Power | 3200 W |
| Microwave Frequency | 2450 MHz |
| Temperature Control Range | 0–500 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Cavity Material | 316L Stainless Steel |
| Cavity Construction | Laser-welded all-steel structure with 5-layer PFA coating |
| Microwave Output | Non-pulsed continuous mode |
| Cooling System | High-capacity corrosion-resistant variable-frequency centrifugal blower |
| Display | Dual-screen interface — capacitive touchscreen + real-time cavity imaging camera |
| Safety Features | Solvent leak detection sensor, auto-locking door mechanism, dual temperature/pressure monitoring, pressure ramp rate control, power calibration, IR temperature correction |
| Software Compliance | 21 CFR Part 11–enabled audit trail, role-based three-tier user management, slope heating mode, power modulation mode, pressure limit enforcement |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPE-40 |
| Automation Level | Fully Automatic |
| Number of Channels | 4 Parallel Channels |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control Range | 0.1–30 mL/min |
| Solvent Selection | Up to 5 Different Solvents |
| Sample Capacity | 4 Samples Simultaneously |
| Sample Loading Volume | 1–30 mL (Expandable up to 5000 mL) |
| Wetted Materials | Alumina Ceramic, PTFE, PEEK |
| Brand | Raykol |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SPEVA |
| Automation Level | Fully Automated |
| Number of Channels | 8 Parallel Channels |
| Extraction Format | Cartridge-Based SPE |
| Flow Rate Control | 0.1–100 mL/min |
| Solvent Selection | Up to 6 Independent Solvent Reservoirs |
| Sample Capacity | 80 Positions |
| Sample Loading Volume | 0.1 mL to Unlimited |
| Wetted Materials | PTFE, Polypropylene (PP), PEEK |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AT-AE06 |
| Price Range | USD 1,400 – 4,200 |
| Extraction Efficiency | 0–100% |
| Extraction Time | 0–999 s |
| Oscillation Method | Sealed, Clean Air Internal Circulation Agitation |
| Simultaneous Extraction Positions | 6 |
| Brand | Safe |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | AT-AE06-Z |
| Extraction Efficiency | 0–99% |
| Extraction Time | 0–999 s |
| Agitation Method | Closed-loop Clean Air Oscillation |
| Simultaneous Extraction Capacity | 6 positions |
| Reagent Dispensing Range | 0–50 mL |
| Dispensing Accuracy | ≥2% |
| Sample Vessel Options | 250 / 500 / 1000 / 2000 mL (standard: 1000 mL) |
| Power Rating | 400 W |
| Voltage | 220 V ± 10% |
| Control Interface | 7-inch Color TFT Touchscreen |
| Waste Handling | Integrated Activated Carbon Filtration for Liquid & Gaseous Effluents |
| Cleaning Mode | Wide-angle Pressurized Spray Rinse |
| Brand | Scienhome |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WSE |
| Automation Level | Semi-Automatic |
| Number of Channels | Multi-Channel (4 Parallel Sample Positions) |
| Extraction Mode | Dispersive SPE (dSPE) |
| Flow Rate Control | Up to 30 mL/min |
| Solvent Selection Ports | 5 Independent Solvent Lines |
| Maximum Sample Volume per Channel | 30 mL |
| Wetted Materials | Chemically Resistant PTFE, Borosilicate Glass, and SPE-Compatible Polymers |
| Compliance | Designed for GLP-compliant workflows in regulated laboratories |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | HSC-2015L |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated Centrifuge |
| Rotor Configuration | Horizontal (Swinging-Bucket) Rotor |
| Max. Capacity | 24 × 1.5/2.0 mL tubes, 4 × PCR 8-tube strips, 12 × 5 mL tubes |
| Max. Speed | 15,000 rpm |
| Max. RCF | 21,400 × g (at 15,000 rpm) |
| Temperature Range | –10 °C to +40 °C |
| Cooling Performance | Reaches 4 °C from ambient in <6 min |
| Acceleration Time (0→15,000 rpm) | ≤15 s (Soft Off mode), ≤45 s (Soft On mode) |
| Deceleration Time (15,000 rpm→0) | ≤15 s (Soft On mode), ≤45 s (Soft Off mode) |
| Speed Increment | 100 rpm steps (500–15,000 rpm) |
| Timer Range | 1 s – 99 min 59 s |
| Noise Level | <58 dB(A) |
| Dimensions (L×W×H) | 385 × 608 × 318 mm |
| Power Supply | 1000 W max / 500 W nominal |
| Rotor Lid | Metal, hermetically sealed |
| Chamber Finish | Corrosion-resistant electrostatically coated surface |
| Braking Mode | SOFT deceleration for sensitive sample integrity |
| Safety Features | Automatic rotor recognition (optional), lid interlock, overspeed/overtemperature/failure self-diagnosis, emergency door release under power loss |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-IIDM |
| Microwave Power | 1000 W (1–100% adjustable) |
| Microwave Frequency | 2450 MHz |
| Photochemical Power/Wavelength | 0–800 W / IR band |
| UV Power/Wavelength | 50 W / 365 nm |
| Ultrasonic Power/Frequency | 10–1000 W / 20–25 kHz |
| Ultrasonic Probe Diameter | Φ8 mm |
| Magnetic Stirring Speed | 50–300 rpm |
| Temperature Control Range | Ambient to 300 °C |
| Temperature Accuracy | ±1 °C |
| Programmable Steps | Up to 200 user-defined protocols |
| Max Sample Volume | 1000 mL |
| Cavity Volume | 25 L |
| Input Power | 220 V ±10% AC, 50 Hz, 3000 W |
| Safety Compliance | Meets GB 4706.21 (Microwave Leakage ≤5 mW/cm²), Dual-level Password Protection, Interlock Door Switch, Magnetron Overtemperature Protection, Real-time Video Monitoring |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | UTE-720 |
| Ultrasonic Power | 720 W (0–100% adjustable) |
| Temperature Range | Ambient to 80 °C |
| Tank Capacity | 22.5 L |
| Internal Tank Dimensions (L×W×H) | 500 × 300 × 150 mm |
| Timer Range | 1–999 min |
| Drain Valve | Yes |
| Construction | Stainless Steel Inner & Outer Chamber with Sound-Dampening Lid |
| Compliance | Designed in accordance with Chinese Pharmacopoeia (ChP) requirements for herbal extraction procedures |
| Brand | SFE / SFE PROCESS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SFE SAS/RESS |
| Price Range | USD 210,000 – 280,000 (FOB Le Havre) |
| Max Temperature | 150 °C |
| Channels | 1 |
| Extraction Volumes | 1 L & 500 mL |
| Max Pressure | 1000 bar |
| Max CO₂ Mass Flow Rate | 70 g/min |
| Primary Application | Nanoparticle Synthesis via Supercritical Anti-Solvent (SAS) and Rapid Expansion of Supercritical Solutions (RESS) Processes |
| Co-solvent Pump | Integrated |
| Solvent Recovery | Yes |
| CO₂ Recovery | Yes |
| Spray Nozzle Vessels | Dual (500 mL & 1 L) |
| Automatic Venting Valve Bank | Yes |
| Precision Mass Flow Control | Coriolis-based |
| Control Architecture | PLC with HMI, Recipe Management, Remote Monitoring Capability, Unattended Operation Support |
| Brand | SFE Process |
|---|---|
| Origin | France |
| Model | SFE LAB100 |
| Maximum Pressure | 1000 bar |
| Maximum Temperature | 150 °C |
| Extraction Vessel Volume | 100 mL |
| CO₂ Mass Flow Rate | 70 g/min |
| Number of Independent Extraction Channels | 2 |
| Co-solvent Pump | Integrated |
| Fractionation Vessels | 2 × 300 mL |
| Cryogenic Trap Capacity | Standard |
| Automatic Valve Switching for Vessel Transfer | Yes |
| Flow Control | Precision Mass Flow Meters |
| Control System | PLC-based, Fully Automated, Recipe-Driven, Unattended Operation |
| Compliance | PED 2014/68/EU (CE Marked), FDA 21 CFR Part 11 Ready, GMP-Compliant Architecture |
| Application Scope | Laboratory R&D, Pharmaceutical Development, Clinical Research, Natural Product Isolation |
| Brand | SFT |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | HPR Series |
| Max. Temperature | 350 °C |
| Max. Pressure | 68.9 MPa (10,000 psi) |
| Reaction Volume | 50 mL to 8 L |
| Stirring | Magnetic Drive Dual-Impeller |
| Safety | ASME-Compliant Vessel with Rupture Disc |
| Control Interface | Color Touchscreen with Closed-Loop PID Temperature & Speed Control |
| Data Output | RS-232 Serial Port |
| Optional Accessories | Sight Glass, Feed/Withdrawal Ports, Cooling Coil, Sample Loop, Reagent Addition Module |
| Compliance | Designed per ASME BPVC Section VIII Div. 1 |
| Typical Applications | Catalytic Synthesis, Hydrogenation, Oxidation, Polymerization, Supercritical Fluid Extraction (SFE), Isomerization, Dehydrogenation |
| Brand | SFT |
|---|---|
| Origin | USA |
| Model | SFT-120XW |
| Maximum Temperature | 200 °C |
| Number of Extraction Vessels | 1–5 |
| Extraction Volume Range | 10–1000 mL |
| Maximum Operating Pressure | 10,000 psi |
| CO₂ Flow Rate | up to 25 mL/min |
| Compliance | Designed for ASTM D7674, ISO 18392, and USP <467> residual solvent analysis workflows |
| Software | SFT-Control v5.2 with 21 CFR Part 11-compliant audit trail |
| Brand | Shanghai Anting |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5C |
| Type | Benchtop Low-Speed Refrigerated Centrifuge |
| Rotor Configuration | Swing-Bucket Horizontal Rotor |
| Max Speed | 4000 rpm |
| Max RCF | 3150 ×g |
| Capacity | 5 mL × 56 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 675 mm × 500 mm × 690 mm |
| Weight | 90 kg |
| Construction | Reinforced Engineering Plastic Housing |
| Safety | Electronic Lid Lock System |
| Cooling | Refrigerated Operation |
| Brand | Shanghai Anting |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIC |
| Type | Benchtop Centrifuge |
| Category | Low-Speed Refrigerated Centrifuge |
| Rotor Type | Swing-Bucket (Horizontal) |
| Max Speed | 3600 rpm |
| Max RCF | 3040 ×g |
| Max Capacity | 5 mL × 120 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 650 mm × 550 mm × 770 mm |
| Weight | 160 kg |
| Construction | Reinforced polymer housing with electronic lid lock |
| Cooling | Refrigerated operation |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | QSE-100 |
| Instrument Type | Solid-Liquid Extraction System |
| Sample Throughput | Up to 12 positions (standard configuration) |
| Operating Temperature Range | Ambient to 200 °C |
| Maximum System Pressure | 200 bar |
| Extraction Cell Volume Options | 1 mL, 5 mL, 10 mL, 22 mL, 34 mL, 66 mL, 100 mL |
| Typical Extraction Time per Sample | 12–25 min (including heat-up, static extraction, flush, and purge cycles) |
| Solvent Compatibility | Polar and non-polar organic solvents (e.g., hexane, acetone, methanol, dichloromethane), water, and solvent mixtures |
| Dimensions (W×D×H) | 580 mm × 620 mm × 650 mm |
| Net Weight | ~75 kg |
| Safety Compliance | CE-marked |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-200QSE |
| Extraction Type | Solid-Liquid Extraction |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP-compliant laboratories |
| Software Interface | Touchscreen GUI with method storage and audit trail capability |
| Safety Features | Pressure-relief valves, temperature/pressure real-time monitoring, leak detection |
| Sample Throughput | Batch processing with programmable sequence execution |
| Solvent Compatibility | Compatible with common organic solvents (e.g., hexane, acetone, dichloromethane, methanol, ethyl acetate) |
| System Architecture | Modular solvent delivery, heated extraction cell, cooled collection module |
| Brand | Shanghai Spectrum |
|---|---|
| Origin | Shanghai, China |
| Model | SP-600QSE |
| Extraction Type | Solid-Liquid Extraction |
| Compliance | EPA Method 3545A |
| Channel Configuration | 6 Parallel Independent Channels |
| Extraction Cell Volumes | 11 mL, 22 mL, 34 mL |
| Max Cell Temperature | 200 °C |
| Safety Feature | Over-Temperature Cut-Off |
| Collection Vial Options | 40 mL / 50 mL / 60 mL |
| Flow Direction | Top-to-Bottom Vertical Elution |
| Cell Positioning | Fixed Vertical Alignment |
| Solvent Pressure Monitoring | Real-Time Alarm Function |
| System Architecture | Fully Automated, Channel-Isolated Fluidics |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | LEXT |
| Instrument Type | Liquid-Liquid Extraction System |
| Temperature Range | 0–130 °C |
| Pressure Condition | Ambient (Atmospheric) |
| Extraction Cell Volume | 15 mL |
| Typical Extraction Cycle Time | 10 min |
| Dimensions (W×D×H) | 600 mm × 585 mm × 570 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SFE-40P |
| Pricing | Available Upon Request |
| Brand | Sineo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SPE100 / SPE200 / SPE400 |
| Automation Level | Fully Automated |
| Channel Count | 1 / 2 / 4 Independent Channels |
| Extraction Mode | Cartridge-Based (Column) SPE |
| Flow Rate Control | 0.1–120 mL/min |
| Solvent Capacity | 8 Solvent Types, Each in 500 mL Independent Bottles |
| Sample Loading Volume | 0.1 mL – 20 L |
| Column Compatibility | 1 mL, 3 mL, 6 mL, 12 mL Standard SPE Cartridges |
| Sealing Technology | Patented Pan-Seal Cap Coupling with H-Axis Compression |
| Pressure Range | 0–145 psi (with Adjustable Pressure Threshold & Overpressure Alarm) |
| Mechanical Arm | X/Y/Z/H Four-Axis Robotic Arm (Positioning Accuracy: ±0.01 mm |
| Sample Needle | 316L Stainless Steel with Liquid-Level Tracking & Puncture Sampling |
| Integrated Functions | On-line Drying (N₂ Blow-Down + Anhydrous Na₂SO₄), On-line Concentration (N₂-Assisted), Waste Segregation (3-Channel Effluent Routing), Multi-Mode Needle Cleaning (N₂ Purge, Solvent Rinse, Agitated Rinse) |
| Software | Cloud-Enabled Platform with Remote Monitoring, Scheduled Run Initiation, Audit Trail, Parameter Validation & GLP-Compliant Logging |
| Power Supply | AC 220 V / 110 V ±10%, 50–60 Hz |
| Operating Environment | 0–40 °C, 10–85% RH |
| Dimensions (Main Unit) | 680 × 580 × 670 mm (H×W×D) |