Empowering Scientific Discovery

Shandong Lunan Ruihong Chemical Instrument Co., Ltd. (formerly Lunan Chemical Instrument Factory)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
OriginShandong, China
ModelRHA-2L (0–2 L/min) / RHA-5L (0–5 L/min)
Output PressureA Port 0–0.4 MPa, B Port 0–0.5 MPa
Hydrocarbon Content<0.1 ppm (as total C1–C4, measured by GC-FID per ISO 8573-5)
Dew Point−15 °C to +40 °C (adjustable via integrated refrigerated dryer and desiccant stage)
Noise Level≤42 dB(A) at 1 m
Power Consumption150 W (RHA-2L), 170 W (RHA-5L)
Dimensions (L×W×H)470 × 230 × 375 mm
Weight22 kg (RHA-2L), 23 kg (RHA-5L)
Input Power220 V AC, 50 Hz
Operating Ambient15–40 °C, RH ≤70%, non-corrosive, low-dust environment
Filtration StagesThree-stage oil-free purification (particulate → coalescing → activated carbon + molecular sieve)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
OriginShandong, China
ModelSP-6801A
Instrument TypeBenchtop Laboratory Gas Chromatograph
Temperature Control RangeAmbient +3°C to 399°C
Temperature Stability±0.1°C
Temperature Accuracy±3% of setpoint
Oven Cooling Rate~8 minutes from 250°C to 50°C
FID Detection Limit≤5×10⁻¹¹ g/s (n-hexadecane in iso-octane)
FID Linear Range≥10⁶
TCD Sensitivity≥2000 mV·mL/mg (benzene/toluene)
TCD Linear Range≥10⁴
ECD Detection Limit≤5×10⁻¹³ g/mL (γ-HCH in iso-octane)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
OriginShandong, China
ModelRHN-300 (RHN-500)
Nitrogen Generation PrincipleElectrolytic Membrane Separation
Output Flow Rate0–300 mL/min (RHN-300)
Output Pressure0.4 MPa
Nitrogen Purity99.996% (v/v, O₂-equivalent basis)
Dew Point≤ –40 °C (typical, at output pressure)
Input Air Pressure0.5 MPa
Power Supply220 V AC, 50 Hz
Power Consumption80 W
Dimensions (L×W×H)420 × 180 × 380 mm
Weight~14 kg (RHN-300)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
ModelGC-8850
OriginShandong, China
Instrument TypeLaboratory Gas Chromatograph
Temperature Control Range4 °C to 450 °C
Ramp Rate0.1–60 °C/min
Cooling Rate300 °C to 50 °C in ~8 min
Carrier Gas Flow Range0–1000 mL/min
Carrier Gas Pressure Range0–400 kPa
Programmable Pressure/Flow Steps16
Injector Max Temp420 °C
Injector Pressure Setpoint Range0–400 kPa
Injector Total Flow Setpoint Range0–1000 mL/min
Temperature Zones8 independent zones
Temperature Resolution0.5 °C
Temperature Accuracy±0.1 °C
Detector OptionsFID, TCD, ECD, FPD, NPD (up to 3 simultaneously)
Data Interface10/100/1000BASE-T Ethernet (IEEE 802.3), MODBUS/TCP compliant
Display7-inch color capacitive touchscreen (hot-swappable, handheld-capable)
Analog-to-Digital24-bit low-noise ADC with baseline storage and subtraction
External Events8 inputs, 2 auxiliary outputs
Injection ModesPacked column, capillary column, 6-port gas valve, optional autosampler
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
ModelRHH-300 / RHH-500
Output Flow Rate0–300 mL/min (RHH-300) / 0–500 mL/min (RHH-500)
Output Pressure0.4 MPa
Hydrogen Purity99.999% (relative to oxygen content)
Power Consumption150 W (RHH-300) / 170 W (RHH-500)
Dimensions (L×W×H)420 × 180 × 380 mm
Weight12 kg (RHH-300) / 13 kg (RHH-500)
Operating Temperature0–40 °C
Relative Humidity<85%
Input Voltage220 V, 50 Hz
Electrolysis PrinciplePEM-free alkaline water electrolysis
Water RequirementDeionized or distilled water
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandLunan Ruihong
OriginShandong, China
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Oven Temperature Range4 °C to 450 °C
Ramp Rate0.1–80 °C/min
Cool-down Rate≤3 min (200 °C → 100 °C)
Carrier Gas Flow Control Range0–1000 mL/min
Carrier Gas Pressure Control Range0–100 psi
Injector Max Temp450 °C
Injector Pressure Setpoint Range0–100 psi
Temperature Zones8 independent zones
Programmed Temperature Stepsup to 16 ramps
Detector OptionsFID, TCD, ECD, FPD, NPD (up to 3 simultaneously)]
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHongtu
OriginShandong, China
ModelSP-6802
Detection Limit (as S in H₂S)0.01 mg/m³ (Type A, non-conversion)
Measurement Range (as S in H₂S, undiluted)0.01–50 mg/m³ (extendable to 0.1–500 mg/m³)
Repeatability (RMS error)<5% (n ≥10, certified H₂S standard gas or CS₂ permeation source)
Column Temperature ControlAmbient to 100°C ±0.2°C
Permeation Source Temperature ControlAmbient to 50°C ±0.1°C
Detector Temperature ControlAmbient to 110°C ±1°C
Converter Furnace TemperatureAmbient to 900°C ±5°C
High-Voltage Power Supply–400 V to –800 V adjustable
ComplianceGB/T 19001–2016 (ISO 9001), GB/T 14001–2016 (ISO 14001)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLuNan RuiHong
ModelQT-3000
Instrument TypeLaboratory Gas Chromatograph
Application FieldPetroleum & Petrochemical Industry
Column Oven Temperature Range+5°C above ambient to 250°C
Temperature Control Accuracy±0.1°C (column oven), ±1°C (inlet/detector)
Max Heating Rate20°C/min
Cooling Time≤8 min (180°C → 35°C)
FID Detection Limit≤1×10⁻¹¹ g/s (benzene)
FID Drift≤0.5 mV/h
Maximum Temperature Program Steps4
InjectorWater-Driven 6-Port Sampling Valve + Manual Syringe Port
SoftwareDedicated Light Hydrocarbon Qualitative/Quantitative Data Processing Suite
ComplianceDesigned for ASTM D1945, ASTM D1946, ISO 6974-1, and GB/T 13610-compliant light hydrocarbon analysis workflows
Added to wishlistRemoved from wishlist 0
Add to compare
OriginImported
Manufacturer TypeAuthorized Distributor
ModelYY-980
Application FieldPetroleum & Petrochemical Industry
Detection PrinciplePyrolysis-Gas Chromatography with Flame Ionization Detection (FID)
Minimum Hydrocarbon Detection0.001 mg hydrocarbon/g rock
Baseline Drift<0.1 mV/30 min
Linear Dynamic Range10⁵
FID Temperature Control380 ± 2 °C
Pyrolysis Furnace Control±1 °C
Sample Probe Temperature Control90 ± 3 °C
Oxidation Furnace Control600 ± 1 °C
Programmed Temperature Ramp Linearity Deviation<1 °C/min
Detector ConfigurationDual Synchronized FID
Valve SystemIntegrated 9-port, 3-port, and 2-position 5-way solenoid valve manifold for fully automated pyrolysis-residual carbon sequence
Signal AmplificationFour-step electronic-switched microcurrent amplifier with high-input-impedance, low-noise op-amp architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
OriginShandong, China
ModelSP-7890Plus
Instrument TypeLaboratory Gas Chromatograph
Application ScopeGeneral-Purpose
Temperature Control Range4°C above ambient to 450°C
Heating Rate0.1–80°C/min
Cooling Rate≤2 min from 200°C to 100°C
Carrier Gas Flow Range & Control0–1000 mL/min
Carrier Gas Pressure Range & Control0–100 psi
Injector Maximum Operating Temperature450°C
Total Injector Flow Setting Range0–1000 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLunan Ruihong
ModelGC-55
TypeLaboratory Gas Chromatograph
Temperature Control Range4 °C to 450 °C
Ramp Rate0.1–120 °C/min
Cool-down Time≤4 min (450 °C → 50 °C)
Carrier Gas Flow Range0–1000 mL/min
Carrier Gas Pressure Range0–100 psi
Injector Max Temp450 °C
Injector Pressure Setpoint Range0–100 psi
Injector Total Flow Setpoint Range0–500 mL/min
Temperature Zones8 independent zones
Programmed Temperature Stepsup to 100 steps
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
EPC/EFC Resolution0.001 psi / 0.001 mL/min
Maximum Split Ratio1:1000
Detector SupportFID, TCD, ECD, FPD, NPD (up to 4 simultaneously)
Data InterfaceEthernet IEEE 802.3 (MODBUS/TCP compliant)
Display10.1″ capacitive color touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
[BrandLuNan RuiHong
ModelLC-1000D
Flow Rate Range0.001–9.999 mL/min
Max Operating Pressure≤ 42 MPa
Flow Precision≤ 0.1% RSD
Injection Volume Range0–30 µL
Column Oven Temperature RangeAmbient to 80 °C
UV-Vis Wavelength Range190–900 nm
Detector TypeDual-Wavelength UV-Vis Photodiode Array (PDA)-Capable Optical System
ComplianceAIA/CDF File Support, GLP-Compliant Audit Trail, 21 CFR Part 11 Ready (Software-Configurable)]