| Brand | Pharmsteri (formerly Entegris) |
|---|---|
| Origin | USA |
| Model | SemiChem APM |
| Measurement Principle | Potentiometric Titration, Standard Addition, and Ion-Selective Electrode (ISE) Methods |
| Accuracy (Potentiometry) | ±0.2% of reading |
| Accuracy (Standard Addition) | ±2.0% of reading |
| Measurement Time | 5 min per cycle |
| Sample Volume | 0.05–5 mL |
| Max Sample Temperature | 93°C (200°F) |
| Power | 110/220 VAC, 50/60 Hz |
| Pneumatic Supply | CDA 414–552 kPa (60–80 psi) |
| DI Water Supply | 138–276 kPa (20–40 psi), 2.0 L/min |
| Drain | 3/4" NPT gravity |
| Enclosure | NEMA 4X-rated industrial housing |
| MTBF | ≥8,500 hours |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiSizer |
| Measurement Principle | Spatial-Temporal Extinction Profiling (STEP) Technology |
| Sample Capacity | 12 positions |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (Stability & Distribution) | 10 nm – 1000 μm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical Wavelengths | Multi-wavelength LED sources |
| Sample Volume per Cell | 0.05 – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100/120/230 V, 50/60 Hz |
| Compliance | ISO 13318-2, ISO/TR 13097, FDA 21 CFR Part 11 (via SEPView software), GLP/GMP-ready audit trail |
| Brand | FlowCam |
|---|---|
| Origin | Japan |
| Model | FlowCam 5000 |
| Particle Size Range | 3–300 µm |
| Camera Resolution | 1920 × 1200 pixels (color CMOS) |
| Frame Rate | up to 100 fps |
| Optical Configurations | 4X (300 µm depth), 10X (100 µm depth), 20X (50 µm depth) |
| Sample Flow Rate | 0.05–2 mL/min |
| Max Particle Concentration | 4 × 10⁶ particles/mL (at 3 µm) |
| Dimensions | 44 × 25 × 27 cm |
| Weight | 10 kg (operational), 24 kg (shipping) |
| Power Consumption | ≤92 W |
| Brand | PSS (Particle Sizing Systems) |
|---|---|
| Origin | USA |
| Model | A7000 Online |
| Detection Principle | Single Particle Optical Sizing (SPOS) |
| Dilution System | Integrated Automated Dilution Module |
| Sampling Mode | Timed Automatic In-Line Sampling |
| Alarm Capability | Real-Time Threshold-Based Alerting |
| Data Output | Concentration-Compensated Raw Counts & Size Distribution |
| Compliance Framework | Supports GLP/GMP Data Integrity Requirements (21 CFR Part 11 Ready via Optional Software Configuration) |
| Brand | Particle Sizing Systems (PSS), USA |
|---|---|
| Origin | USA |
| Model | Nicomp ZLS |
| Zeta Potential Range | ±500 mV |
| pH Range | 1–14 |
| Temperature Range | 0–90 °C |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Accuracy | 99% |
| Repeatability | 99% |
| Brand | Pharmsteri (Intertek) |
|---|---|
| Origin | USA |
| Model | AccuSizer Mini |
| Detection Principle | Single Particle Optical Sensing (SPOS) with LE/LS/FX/FX-Nano Sensor Options |
| Particle Size Range | 0.15–400 µm (configurable by sensor) |
| Concentration Range | Up to 1×10⁶ particles/mL (FX/FX-Nano with auto-dilution) |
| Resolution | 512 channels |
| Minimum Detectable Size | 150 nm (FX-Nano) |
| Sample Handling | Direct, one-step, or two-step automated dilution |
| Compliance | Designed for GLP/GMP environments |
| Interface | PLC-compatible digital I/O |
| Power | 100–240 VAC, 3-phase, C14 inlet |
| Pneumatic Supply | 3.5–5.6 kg/cm² (50–80 psi) |
| Liquid Inlet/Outlet Pressure | 0.2–2.1 kg/cm² (3–30 psi) / zero-backpressure discharge |
| Dimensions | 863.6 × 355.6 × 279.4 mm (34 × 14 × 11 in) |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiSizer 65X |
| Measurement Principle | STEP-Technology (Spatial and Temporal Extinction Profiles) |
| Sample Throughput | 12 positions simultaneously |
| Temperature Control Range | 4 °C to 60 °C (±1 K) |
| Particle Size Range (ISO 13318-2) | 20 nm – 100 µm |
| Stability & Sedimentation Velocity Range | 10 nm – 1000 µm |
| Concentration Range | 0.00015 % – 90 % w/w |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Acceleration Force | 6 × g to 2300 × g |
| Optical Wavelength Options | 470 nm (blue) and 865 nm (NIR) |
| Sample Volume | 0.05 – 2.0 mL |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (via SEPView software audit trail), GLP/GMP-ready |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiReader PSA |
| Measurement Principle | STEP Technology™ (Spatial and Temporal Extinction Profiles) |
| Acceleration Method | Gravimetric Tilt Enhancement (0°–30° tilt, up to 10× g-equivalent separation rate) |
| Detection | Multi-wavelength LED array (470 nm, 525 nm, 625 nm, 850 nm) |
| Optical Sensors | >9,000 high-resolution photodiodes per detector |
| Sample Volume | 0.5–4.0 mL |
| Concentration Range | 0.00015–75 wt% |
| Particle Size Range (PSD) | 500 nm–300 µm (ISO 13317 compliant) |
| Stability Assessment Range | 200 nm–2000 µm |
| Viscosity Range | 0.8–10⁸ mPa·s |
| Density Range | up to 22 g/cm³ |
| Temperature Control | Ambient +3°C to 60°C (±1 K) |
| Tilt Angles | 0°, 5°, 10°, 15°, 20°, 25°, 30° |
| Minimum Acquisition Interval | 0.5 s |
| Data Output | Extinction profiles (E(z,t)), velocity distribution Qᵥ(v), intensity-weighted PSD Qᵢₙₜ(x), volume-weighted PSD Q₃(x) |
| Compliance | ISO/TR 13097, ISO 13317, ASTM D7827, FDA 21 CFR Part 11 (audit trail & electronic signature ready), GLP/GMP-ready architecture |
| Brand | LUM GmbH |
|---|---|
| Origin | Germany |
| Model | LUMiFlector |
| Application Principle | Near-Infrared and UV-Visible Multi-Reflection Spectroscopy (MRS®) |
| Measurement Time | <20 s (lab), <8 s (inline) |
| Sample Handling | Non-contact, no sample preparation, no reagents |
| Output Parameters | Up to 4 simultaneous quantitative attributes (e.g., fat, protein, dry matter, total solids) |
| Calibration | Product-specific multivariate calibration models |
| Interface | 4× 4–20 mA analog I/O, 4× 24 V digital outputs, VARINLINE® process housing (inline version) |
| Compliance Context | Designed for GLP/GMP-aligned QA/QC environments |