| Brand | Avantor |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | MFLA74905-02 |
| Instrument Type | Micro Syringe Pump |
| Flow Rate | 1.28 pL/min to 88.28 mL/min |
| Accuracy | ±0.5% |
| Repeatability | ±0.05% |
| Linear Force | 30 lbf (133 N) |
| Compatible Syringe Volume Range | 0.5 µL – 60 mL |
| Interface | RS-232, RS-485, USB, 15-pin D-sub |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Display | Full-color capacitive touchscreen |
| Mounting | Horizontal or vertical orientation with auto-rotating UI |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | MFLA74900-05 |
| Flow Rate | 0.2 µL/h to 60 mL/h |
| Accuracy | ±0.5% |
| Repeatability | ±0.2% |
| Syringe Capacity | 10 µL–60 mL |
| Linear Force | 20 lbf (9.1 kgf) |
| Power Supply | 230 VAC, 50/60 Hz |
| Warranty | 1 year |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | Traceable TDL/TGW |
| Wireless Protocol | Proprietary Self-Organizing Mesh RF |
| Max Nodes per Gateway | 30 |
| Sampling Interval | 1 min – 24 hr |
| Onboard Memory | 60,000 readings |
| Battery Life | >3 years (TDL), ≥12 hrs (TGW on backup) |
| IP Rating | IP65 (TDL), IP30 (TGW) |
| Operating Temp | −20°C to +60°C (TDL), −5°C to +45°C (TGW) |
| RF Range | >100 m line-of-sight, wall-penetrating |
| Sensor Compatibility | Digital, RS-485, PT100 |
| Data Resilience | Local caching + auto-resume transmission |
| Compliance | Supports 21 CFR Part 11 audit trail readiness, GLP/GMP-aligned data integrity architecture |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Industrial Display Instrument |
| Model | VWRI620-1980 |
| Channel Count | 1 |
| Display | 6-digit LCD (10.2 mm digit height) |
| Battery | 9 V (1 unit, ~1 year life) |
| Probe Type | Platinum RTD (Pt100 or Pt1000, Class A or AA per IEC 60751) |
| Probe Options | 37804-06 (7" × 0.13" stainless steel stem, 6' cable) / 37804-07 (1" × ¼" PTFE-insulated bullet probe, 10' cable) |
| Temperature Range | –200.000 to +500.000 °C |
| Resolution | 0.1 °C to 0.0001 °C (user-selectable via resolution key) |
| Accuracy | ±0.05 °C or ±0.05% of reading (whichever is greater), valid between –80 °C and +290 °C |
| Data Logging | Internal hourly min/max recorder (24-hour rolling buffer) |
| Response Time | ≤0.33 s for liquids/air/gases/semi-solids (3 updates/sec) |
| Certifications | NIST-traceable Traceable® Certificate included (ISO/IEC 17025-accredited calibration documentation) |
| Physical Dimensions | 89 × 32 × 140 mm |
| Weight | 230 g |
| Accessories | Battery, probe, cable, RS232/USB computer interface, rugged plastic carrying case, Traceable® certificate |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Type | Micro-syringe Pump |
| Flow Rate | 5 pL/min – 200 mL/min |
| Accuracy | ±0.355% |
| Repeatability | ±0.05% |
| Syringe Capacity | 0.5 µL – 140 mL |
| Linear Force | 75 lbs |
| Interface | RS-232, RS-485, USB, 15-pin D-sub |
| Syringe Travel Rate | <190.8 mm/min |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | VWRI620-2635 |
| Temperature Range | -200.00 to 105.00 °C |
| Resolution | 0.01 °C |
| Accuracy | ±0.25 °C |
| Sensor Type | Platinum RTD (316 stainless steel sheath) |
| Cable Length | 1 m |
| Data Storage Capacity | 525,600 points |
| Calibration Points | -196 °C, -80 °C, 0 °C, and 100 °C |
| Brand | Antylia/Cole-Parmer |
|---|---|
| Model | HI-200D |
| Temperature Stability (in tube) | ±0.1°C |
| Rotational Speed Range | 0–20 rpm |
| Oscillation Frequency | 5–20 or 15–60 opm |
| Max Operating Temperature | 100°C |
| Min Operating Temperature | Ambient +10°C |
| Temperature Accuracy | ±0.3°C |
| Temperature Uniformity (in tube) | ±0.5°C |
| Chamber Uniformity | ±1.5°C |
| Temp Set Resolution | 0.1°C |
| Dimensions (L×W×H) | 285 × 385 × 555 mm |
| Voltage | 230 V, 50–60 Hz |
| Power Consumption | 750 W |
| Net Weight | 24 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-21ZX |
| Instrument Type | Fixed-Mount |
| Measurement Range | 0–10 ppm |
| Detection Limit | 0.01 ppm (resolution) |
| Response Time | <60 seconds (T90) |
| Zero Drift | <±0.02 ppm/week |
| Resolution | 0.01 ppm |
| Dimensions | 110 × 220 × 64 mm (L×W×H) |
| Weight | 570 g |
| Power Supply | 12–24 VDC, 500 mA |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Brand | PCRmax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eco48 |
| Price | USD 1 (FOB) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 74900-05 (Single-Channel), 74900-15/74900-25/74900-65/74901-05 (Dual-Channel), 74900-35/74900-45/74900-85/74901-15 (10-Channel) |
| Accuracy | ±0.5% |
| Repeatability | ±0.1% |
| Flow Rate Range (Single) | 0.2 µL/h–500 mL/h |
| Flow Rate Range (Dual/10-Channel) | 1 nL/h–147 mL/min |
| Syringe Capacity | 10 µL–140 mL |
| Linear Force | 9.1 kg (Single), 18.1 kg (Dual/10-Channel) |
| Power Supply | 230 V, 50/60 Hz |
| Certifications | CE |
| Interface | RS232, TTL I/O (Programmable Models) |
| Dimensions (L×W×H, cm) | 23×10×15 (Single), 28×12.7×23.5 (Dual), 28×15.2×30.5 (10-Channel) |
| Brand | Cole-Parmer |
|---|---|
| Model | 36630-00 |
| Origin | USA |
| Instrument Type | Benchtop |
| Temperature Range | −30 °C to +150 °C |
| Stirring Speed | 350–1200 rpm |
| Independent Reaction Vessels | 10 |
| Vessel Volume Capacity | 1–25 mL |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.5 °C |
| Stirring Speed Resolution | 1 rpm |
| Stirring Speed Accuracy | ±10 rpm |
| Max Heating/Cooling Rate | 5 °C/min |
| Inter-vessel Temp Differential | Up to 180 °C |
| Optional Accessories | Reflux condensers, inert gas/vacuum manifolds, multi-channel NIR probes (Clarity System), Multi-Temp10 thermal control module, Integrity software suite |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 36050-05 |
| Operating Temperature | 760°C (1400°F) |
| Length | 0.6 m |
| Width | 1.3 cm |
| Power Rating | 156 W |
| Voltage | 120 VAC |
| Construction | Dual resistive elements knitted in series, insulated with high-temp Samox® fiberglass braid |
| Safety Note | Non-overlapping installation required |
| Termination | Reusable tie-down ends, 0.6 m integrated power cord |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 44175-00 |
| Temperature Range | −10 to 100 °C |
| Temperature Accuracy | ±1 °C |
| Timer Function | Up to 30 days with audible alarm |
| Data Storage | Built-in memory |
| Interface | RS232 (IBM PC compatible) |
| Power Supply | 100–232 V AC |
| Standard Configuration | Main unit + 12 V DC power supply (modules sold separately) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 36402-09 |
| Temperature Range | Ambient to 130 °C |
| Temperature Uniformity | ±0.3 °C |
| Input Voltage | 230 V AC |
| Power Rating | 150–400 W (model-dependent) |
| Module Capacity | Single-module configuration |
| Heating Module Depth | 2.8 cm (03137-00 only) |
| Brand | Avantor |
|---|---|
| Origin | USA |
| Model | 94460-07 |
| Temperature Range | −50.00 to +70.00 °C |
| Accuracy | ±0.25 °C |
| Resolution | 0.01 °C |
| Probe Type | Patented Bottle Probe |
| Memory Capacity | 525,600 readings |
| Alarm Events | Up to 10 unique events |
| Data Export | USB flash drive (CSV format) |
| Compliance | CDC vaccine storage guidelines |
| Certifications | Traceable® Certificate of Calibration included |