Shanghai Weichuan Precision Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1000
Measurement Ranges0–1000 ppm, 0–1% (10,000 ppm), 0–25% O₂
Accuracy±1% of full scale
Resolution0.01 ppm (in ppm range)
Sensor TypeGPR-12-100-M electrochemical cell
Sensor Lifetime24 months at 25°C with average O₂ < 1000 ppm
Response Time (t₉₀)10 s
Recovery Time to 100 ppm after air exposure10 min in N₂
Operating Temperature5–45°C
Sample Pressure5–30 psig inlet, vented to atmosphere
Flow Rate0.25–2.5 L/min
Display2.75″ × 1.375″ monochrome LCD
Enclosure RatingNEMA 4X
Dimensions4″ × 9″ × 3″
Weight8 lbs
PowerRechargeable battery (60-day standby life)
Output Signal0–1 V analog
Temperature CompensationBuilt-in
CalibrationAmbient air or certified gas ≥80% of selected span
CertificationsIntrinsically safe or explosion-proof rated (per applicable Class I Div 1/Zone 1 requirements)
Wetted Materials316 stainless steel
Optional AccessoriesIntegrated sampling pump, carrying case, inlet particulate filter, on/off switch module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1900
SensorGPR-12-333
Measurement PrincipleElectrochemical (Galvanic)
Accuracy<1% of Full Scale
Range Options0–10 ppm, 0–100 ppm, 0–1000 ppm, 0–1%, 0–25% O₂
Resolution0.001 ppm
Response Time (t₉₀)<10 s
Operating Temperature5–45 °C
Sample Pressure5–30 psig (inlet), max 100 psig
Sample Flow Rate0.5–1.5 L/min (recommended: 1 L/min)
Output SignalsIsolated 4–20 mA and 0–1 V analog
Power Supply19–28 VDC or 220 VAC (configurable)
Enclosure Dimensions7″ × 4″ × 4.5″ (H×W×D)
Weight8 lbs
Wetted Materials316 Stainless Steel
CertificationsCE, ISO 9001, Class I, Division 1, Groups A–D (with appropriate intrinsically safe barrier)
Sensor Lifetime24 months at ≤1000 ppm avg O₂, 25 °C
CalibrationAuto-zero & span
CompensationAutomatic temperature & pressure compensation
Display5″ × 2.75″ backlit LCD
Interface1/8″ compression fittings, RS-232 serial port
IP RatingNEMA 4X equivalent (front panel with sealed membrane keypad)
Warranty12 months (instrument + sensor)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-18 Series
Measurement PrincipleElectrochemical Fuel Cell
Range0–1/10/100/1000 ppm, 0–1%/25% FS
Sensor TypeMicro-fuel-cell (e.g., XLT-12-333 for CO₂-rich streams)
Accuracy<0.5% FS
Linearity>0.995
Response Time (T₉₀)10 s
Operating Temperature5–45 °C
Storage Temperature–30 °C
Sample Flow Rate1–5 SCFH (recommended: 2 SCFH)
Inlet Pressure5–30 psig (max 100 psig)
Outlet PressureAmbient
Power Supply220 VAC, 50/60 Hz
Output Signals0–1 V DC and isolated 4–20 mA
Display Resolution0.01 ppm
Enclosure RatingNEMA 4X/7, Class I, Division 1, Groups B–D
CertificationsFM, CSA, CE, ISO 9001
Calibration Gas80% FS O₂ standard
Temperature CompensationBuilt-in
Gas CompatibilityInert gases, He, H₂, CO₂-containing mixtures (with XLT sensor), acidic gas streams
Optional AccessoriesXLT-12-333 sensor, heated sample conditioning system (for sub-ppm analysis), flow control valve, shut-off valve, rotameter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2300
Measurement PrincipleSupergalvanic Electrochemical Sensor
Range0–100% O₂ (Auto/Manual Span Selection)
Accuracy±0.1% of full scale (at 25°C, 1 atm)
Resolution0.01% of full scale
LinearityR² > 0.995
Response Time (T₉₀)10 s
Recovery Time (Air → 10 ppm)30 min (60 s with purge)
Sensor Lifetime>24 months at 1000 ppm O₂
PowerRechargeable battery (30-day runtime per charge)
EnclosureAnodized aluminum, NEMA 4X rated
Dimensions5" × 9" × 3" (127 × 229 × 76 mm)
Weight8 lbs (3.5 kg)
Operating Temperature−5 to +45°C with built-in temperature compensation
Pressure Range5–100 psig
Sample Flow Rate0.2–5 L/min (recommended: 1 L/min)
CertificationsISO 9001, CE, Class I, Division 1, Groups A, B, C, D (Intrinsically Safe)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-3500MO
PrincipleSupergalvanic electrochemical sensor
Range0–100% O₂
Accuracy±0.1% O₂ (at ambient temperature, atmospheric pressure, and fixed flow rate)
Resolution0.01% O₂
LinearityR² > 0.995
Response Time (t₉₀)13 seconds
Sensor Lifetime>24 months
CertificationsISO 9001, CE, CSA/NRTL
PowerRechargeable battery with 220 V AC charger
DisplayBacklit LCD showing real-time O₂ concentration, sample pressure, and temperature
Sample Flow Rate0.2–3 L/min (recommended: 1 L/min)
Calibration Gas98–100% O₂ standard
Operating Pressure Range5–100 psig (with automatic pressure compensation)
Operating Temperature Range–5 to +45 °C (with automatic temperature compensation)
Gas Path ComponentsIntegrated flow control valve, rotameter, rapid purge system, 1/8" Swagelok® compression fittings
EnclosureAnodized aluminum, NEMA 4X rated
Dimensions5" × 9" × 3" (127 × 229 × 76 mm)
Weight8 lbs (3.6 kg)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1100
Measurement PrincipleElectrochemical Fuel Cell
Range Options0–10 / 0–100 / 0–1000 ppm, 0–1% / 0–25% FS
Accuracy<1% FS
Linearity>0.995
Response Time (t₉₀)10 s
Recovery Time to 10 ppm≤60 s
Sensitivity Drift<0.5% FS
Temperature CompensationBuilt-in
Operating Temp5–45 °C
Sample Flow Rate0.25–2.5 L/min (recommended: 1 L/min)
Inlet Pressure5–30 psig
Outlet PressureAmbient
Display Resolution0.01 ppm
Output Signal0–1 VDC
Enclosure RatingNEMA 4X (aluminum-clad)
Dimensions102 × 229 × 76 mm
Weight3.5 kg
CertificationsCE, ISO 9001, Class I, Division 1, Groups A–D (intrinsically safe)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1200
Detection PrincipleElectrochemical (Galvanic)
Sensor TypeGPR-12-333 (standard), XLT-12-333 (optional)
Measurement Range0–10 / 0–100 / 0–1000 ppm, 0–1% / 0–25% FS
Accuracy<1% FS (at 25°C, 1 atm)
Sensitivity<0.5% FS
LinearityR² > 0.995
Response Time (T₉₀)10 s
Recovery Time (to <10 ppm)≤60 s
Operating Temperature5–45°C (GPR sensor), –20–45°C (XLT sensor)
Sample Flow Rate0.5–5 SCFH (recommended: 2 SCFH)
Inlet Pressure5–30 psig
OutletVent to atmosphere
Gas CompatibilityH₂, He, N₂, Ar, CO₂ (with XLT), acidic gases, mixed industrial gases
Enclosure RatingIP65 (waterproof housing)
Safety CertificationATEX/IECEx-compliant intrinsic safety — Class I, Division 1, Groups A–D
PowerRechargeable Li-ion battery (60-day standby life per charge)
Output Signal0–1 V analog
DisplayBacklit LCD
Sampling SystemStainless steel bypass manifold
CalibrationTwo-point (zero/span) with 80% FS span gas recommended
ComplianceCE-marked, ISO 9001:2000 certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2500ATEX
Measurement PrincipleBreakThrough electrochemical sensor technology
Range0–1%, 0–10%, 0–20%, 0–25% O₂ (selectable)
Accuracy±0.1% O₂ (calibrated with 98–100% O₂ in N₂ standard gas)
Resolution0.01% O₂
Sensor Lifetime24 months in 100% O₂
LinearityR² = 0.995
T90 Response Time13 seconds
Pressure CompensationAutomatic, 5–100 psig
Temperature CompensationAutomatic, –5 to +45 °C
Sample Flow Rate1–3 SCFH (recommended: 2 SCFH ≈ 1 L/min)
Analog Outputs0–1 V DC and 4–20 mA
Digital InterfaceUSB for remote control and data logging
DisplayBacklit LCD with real-time pressure & temperature readout
Enclosure MaterialAnodized aluminum
MountingPanel-mount (cutout: 178 × 223 mm)
Dimensions190 × 274 × 315 mm (W × H × D)
Weight~5 kg
CertificationsCE, ISO 9001
Hazardous Area RatingATEX II 2G Ex d IIB T4 Gb
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1200MS
Measurement Range0–1, 0–10, 0–100, 0–1000 ppm (selectable)
Detection Limit10 ppb
Accuracy±1% of full scale
Sensor TypeElectrochemical (GPR-12-2000MS), maintenance-free
Expected Sensor Life24 months at 25°C and avg. 100 ppm O₂
Response Time (t₉₀)10 s
Recovery Time to 10 ppm in N₂ after air exposure20 min
Operating Temperature5–45 °C
Sample Pressure5–30 psig inlet, vent to atmosphere
Flow Rate0.25–2.5 L/min (recommended: 1 L/min)
Display2.75″ × 1.375″ LCD, resolution 0.01 ppm
Enclosure RatingNEMA 4X
Dimensions8.6″ × 9″ × 3″
Weight12 lbs
PowerRechargeable battery (60 days standby, ~1 day with pump active)
CertificationsCE, ATEX/IECEx compliant intrinsic safety for Class I, Div. 1, Groups A, B, C, D
Sample Wetted Materials316 stainless steel
Output Signal0–1 V analog
LinearityR² ≥ 0.995 across all ranges
Temperature CompensationBuilt-in
User InterfaceRotary range selector, waterproof membrane keypad, LED status indicators (low battery, charging)
Optional AccessoriesIntegrated sampling pump, explosion-proof carry case, inline particulate filter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-1300
Measurement PrincipleGalvanic Electrochemical Sensor
Range0–10 / 0–100 / 0–1000 ppm (user-selectable)
Accuracy±1% of full scale (at 25°C, 1 atm)
Resolution0.1% of full scale
LinearityR² > 0.995
T90 Response Time≤10 s
Recovery Time≤30 min (from air to 10 ppm)
Sensor Lifetime>24 months at 1000 ppm O₂
PowerRechargeable battery (30-day operation per charge)
DisplayBacklit LCD with real-time sample pressure & temperature readout
EnclosureAnodized aluminum, NEMA 4X rated
Explosion ProtectionClass I, Division 1, Groups A, B, C, D (intrinsic safety certified)
Operating Temperature–5°C to +45°C with built-in temperature compensation
Operating Pressure5–100 psig
Sample Flow Rate0.1–5 L/min (recommended: 1 L/min)
CertificationsISO 9001, CE
Dimensions5" × 9" × 3" (W × H × D)
Weight8 lbs (≈3.5 kg)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2500MO
Measurement Range0–100% O₂
Accuracy±1% FS (±0.1% FS when calibrated with 95–100% O₂ standard)
Sensor TypeGPR-11-120-4 electrochemical cell
Sensor Lifetime24 months at 25°C
Response Time (t₉₀)10 seconds
Operating Temperature5–45°C
Sample Pressure5–30 psig inlet, vent to atmosphere
Sample Flow Rate0.5–2.5 L/min (recommended: 1.0 L/min)
Output Signal4–20 mA (2-wire, 12–28 VDC
Display2.75″ × 1.375″ LCD, 0.1% resolution, real-time temperature & pressure readout
Enclosure RatingNEMA 4X
Dimensions4″ × 9″ × 3″
Weight8 lbs
CertificationsCE, intrinsically safe for Class I, Division 1, Groups A–D (with appropriate barrier)
CompensationAutomatic temperature and pressure compensation
CalibrationSingle-point, using certified gas ≥80% of full scale
Sample Wetted Materials316 stainless steel
OptionalRemote sensor mounting kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2000
Measurement Range0–1%, 0–5%, 0–10%, 0–25% (user-selectable)
Full-Scale Accuracy<1% FS
Resolution0.001% O₂
Response Time (t₉₀)10 s
Operating Temperature–10°C to +45°C (GPR sensor), –20°C to +45°C (XLT sensor)
Sample Pressure5–30 psig inlet, vent to atmosphere
Flow Rate0.25–2.5 L/min (recommended: 1.0 L/min)
Output Signal0–1 V analog
Sensor Lifetime36 months (GPR-11-32-RT, 25°C)
Enclosure RatingNEMA 4X
Weight8 lbs
Dimensions4" × 9" × 3"
CertificationsCE, ATEX/IECEx compliant for Class I, Div. 1, Groups A, B, C, D (intrinsically safe)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ModelDVNext
Viscosity Range0.01–250 mPa·s
Instrument TypeBenchtop (with portable operational flexibility)
ComplianceFully compliant with FDA 21 CFR Part 11 in standalone mode
ConnectivityEthernet and LIMS integration supported
Rotor MountingOne-hand quick-coupling mechanism
LevelingIntegrated electronic auto-leveling system
Operating EnvironmentAmbient temperature (15–30 °C)
Application ClassGeneral-purpose rotational viscometry for QC, R&D, and production environments
Added to wishlistRemoved from wishlist 0
Add to compare
OriginShanghai
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
ModelSYD-2806H
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAII
OriginUSA
ModelGPR-2800 AIS
Explosion ProtectionATEX II 2G Ex ia IIC T4 Ga / UL Class I, Division 1, Groups A–D
Measurement Range0–1%, 0–5%, 0–10%, or 0–100% O₂ (selectable)
Accuracy±1% of full scale
Response Time (t₉₀)10 s
Operating Temperature–10 to 45°C (sensor), –20 to 45°C (electronics)
Pressure CompensationYes
Temperature CompensationYes
Output4–20 mA (2-wire, loop-powered)
Power Supply12–28 VDC (24 VDC typical with safety barrier)
Enclosure RatingNEMA 4X (IP66)
Weight3.6 kg (8 lbs)
Sensor TypeElectrochemical (GPR-11-32-4), maintenance-free
Sensor Lifetime≥36 months at 25°C
Display2.75″ × 1.375″ backlit LCD, 0.01% resolution
Flow Rate0.25–2.5 L/min (recommended: 1.0 L/min)
LinearityR² ≥ 0.995 across all ranges
CalibrationSingle-point using certified gas ≥80% of selected span
Sample Interface1/8″ compression fitting
Wetted MaterialsCorrosion-resistant (e.g., 316 SS, FKM, PTFE)
OptionalRemote sensor mounting (XL-CX-2 cable kit)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBrookfield
OriginUSA
ModelDIN Adapter (DAA)
ComplianceDIN 53019, ASTM D2196 Equivalent
Sample Volume16–20 mL
GeometryCylindrical Couette
Shear Rate CalculabilityYes
Included Components3 rotors + 2 sample cups
Viscosity Range (LV/T series)1.9–50,000 mPa·s
Viscosity Range (RV/HA/HB series)10.0–50,000 mPa·s
Mounting CompatibilityAll Brookfield standard laboratory viscometers and rheometers (DV1, DV2, DV3, RV, HA, HB series)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIEST
OriginFujian, China
ModelBER2500
Power Supply200–240 VAC, 50–60 Hz
Power Consumption450 W
Dimensions (W×D×H)355 × 320 × 800 mm
Weight85 kg
Resistance Range1 µΩ to 3.1 kΩ
Resistance Resolution0.1 µΩ
Resistance Accuracy±0.5% FS
Pressure Control Range5–60 MPa (with Ø14 mm electrode)
Pressure Resolution0.05 MPa
Pressure Accuracy±0.3% FS
Thickness Measurement Range0–5 mm
Thickness Resolution/Accuracy0.1 µm / ±1 µm
Temperature Range0–50 °C
Humidity Range0–90% RH
Temp/Humidity Accuracy±2 °C / ±5% RH
ComplianceCE-certified, ISO 9001 certified, Chinese High-Tech Enterprise certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMichell
OriginUnited Kingdom
ModelSF52
Product TypeOnline Dew Point Transmitter
Measurement PrincipleChilled Mirror–Compensated Semiconductor Sensor
Operating Temperature Range-40 to +60 °C
Accuracy (Dew Point)< ±2 °C
Repeatability< ±0.5 °C
Stability< 1 °C/year
Response Time (T90)< 10 s
Output Signals4–20 mA, 0–1 V, 0–5 V, or 0–10 V
Supply Voltage8–30 V DC (14–30 V DC required for 0–10 V output)
Power Consumption9 mA + load current
Supply Voltage Effect±0.005 %RH/V
Dew Point Range-40 to +60 °C
Absolute Humidity Range0 to 200 g/m³
Accuracy (Absolute Humidity)0.4 to 3 g/m³ (dependent on measured value)
Pressure RatingUp to 20 bar (gauge)
Filter TypeBuffered flow-compensated sintered stainless-steel filter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATAGO
OriginJapan
ModelPAL-32s
Product TypeHandheld Digital Refractometer
Temperature ControlYes (Automatic Temperature Compensation)
DisplayDigital LCD
Measurement Range0–20% (w/w) H₃PO₄
Accuracy±0.4%
Temperature Compensation Range10–40 °C