- All
- Favorite
- Popular
- Most rated
| Brand | Zhonglu |
|---|---|
| Model | DS C--500ARD |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Sample Capacity | 1 |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/Ar) |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB 2.0, RS-232 |
| Calibration Standards | Indium (In), Tin (Sn), α-Al₂O₃ reference material |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XRW-300A6 |
| Temperature Range | 50–300 °C |
| Heating Rates | 120 °C/h or 50 °C/h (user-selectable) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Deflection Measurement | Digital micrometer with 0.001 mm resolution, 0–13 mm range |
| Specimen Span | 64 mm or 100 mm (ASTM-compliant adjustable) |
| Sample Stations | 6 independent test positions |
| Heating Medium | Methyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt, supplied separately) |
| Control Algorithm | Fuzzy PID with PWM output |
| Data Acquisition Rate | 7 samples/second per channel (4–8 channels simultaneously) |
| Human-Machine Interface | 7-inch capacitive color touchscreen, bilingual (English/Chinese) OS |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | Zhonglu |
|---|---|
| Model | DSC-500ARD |
| Type | Differential Scanning Calorimeter (DSC) |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Sample Capacity | 1 position |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas automatic switching (e.g., N₂/air) |
| Display | 10.1″ industrial-grade capacitive touchscreen (24-bit color) |
| Data Interfaces | USB 2.0, RS-232 |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Model | DTA-1350 |
| Temperature Range | RT to 1350 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DTA Signal Range | 0–±2000 µV |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Control Method | PID-based Programmable Temperature Control |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Sensor Material | Corrosion- and oxidation-resistant alloy |
| Atmosphere Control | Automated internal gas switching |
| Calibration Standard | Certified Sn reference material included |
| Compliance | ASTM E794, ISO 11357-1, GB/T 19466.1–2004 |
| Brand | Zhonglu |
|---|---|
| Model | JLD-2000I |
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Price | USD 2,800 (FOB Shanghai) |
| Extraction Capacity | 2000 mL |
| Heating Power | 500 W |
| Max Heating Temperature | 300 °C |
| Analytical Balance Range | 0–100 g |
| Readability | 0.0001 g |
| Vacuum Drying Chamber Temp Range | RT+10 to 250 °C |
| Vacuum Level | ≤133 Pa |
| Compliance Standards | GB/T 29848-2013, IEC 62788-1-6, ASTM D2765, ISO 10147:2011, CQC 3307-2013 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-500ARD |
| Price | USD 4,200 (approx.) |
| Temperature Range | Ambient to 500 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1 |
| Temperature Resolution | 0.01 °C |
| DSC Signal Range | 0 to ±200 mW / 0 to ±500 mW |
| Atmosphere Control | Dual-gas automatic switching |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB 2.0, RS-232 |
| Calibration Standards | Indium (In) and Tin (Sn), certified reference materials included |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DSC-500ARD |
| Price | USD 4,200 (approx.) |
| Temperature Range | Ambient to 500 °C ±0.1 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Repeatability | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 1 |
| Temperature Resolution | 0.01 °C |
| DSC Signal Range | ±200 mW / ±500 mW |
| Atmosphere Control | Dual-gas automatic switching |
| Display | 10.1-inch 24-bit color industrial touchscreen PC |
| Data Interfaces | USB, RS-232 |
| Calibration Standards | Indium and Tin reference materials included |
| Compliance | ISO 11357, GB/T 19466, ASTM D3417 |
| Key | Brand: Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | MFI-1221 |
| Test Method | Mass Flow Rate (MFR) & Volume Flow Rate (MVR) |
| Temperature Range | 100–450 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Recovery Time | ≤2 min after charge |
| Die Dimensions | 2.095 mm ±0.005 mm ID, 8.000 mm ±0.025 mm length |
| Barrel ID | 9.550 mm ±0.007 mm |
| Piston Displacement Resolution | 0.002 mm |
| Piston Accuracy | ±0.02 mm |
| Load Application | Manual |
| Display | 5-inch HD color TFT touchscreen (bilingual: EN/CN) |
| Power Supply | 220 VAC ±10%, 50 Hz, 0.5 kVA |
| Weight | ~25 kg (main unit), ~25 kg (accessories) |
| Compliance | GB/T 3682–2018, ASTM D1238, ISO 1133:2005, BS 2782 |
| Brand | Zhonglu |
|---|---|
| Model | XRW-300B4 |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Application | Heat deflection temperature (HDT) and Vicat softening temperature (VST) testing of thermoplastics, thermosets, fiber-reinforced composites, laminates, and electrical insulating materials |
| Standards Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648 |
| Temperature Control Range | Ambient to 300 °C |
| Max. Temp. Deviation | ±0.5 °C |
| Heating Rates | 50 °C/h or 120 °C/h (adjustable between 50–120 °C/h) |
| No. of Test Stations | 4 |
| Deflection Measurement Range | 0–10 mm |
| Deflection Accuracy | ±0.005 mm |
| Resolution | 0.001 mm |
| Span Lengths | 64 mm or 100 mm |
| Thermal Expansion Coefficient of Test Frame | <0.005 /100 °C |
| Temperature Sensor Type | High-stability platinum RTD |
| Displacement Sensor | Optical-grating digital micrometer |
| Control Method | PC-based software with real-time curve display and automated reporting |
| Safety Protections | Dual hardware/software temperature limit switches (30 A Korean thermal cutoff), end-of-test auto-halt, administrator password lockout |
| Heating Power | 4000 W |
| Heat Transfer Medium | Methyl silicone oil or transformer oil |
| Cooling | Natural convection above 150 °C |
| Brand | Zhonglu |
|---|---|
| Model | XRW-300C6 |
| Origin | Shanghai, China |
| Manufacturer | Zhonglu Instrument Co., Ltd. |
| Control Interface | 7-inch touchscreen + PC software |
| Test Frames | 6 |
| Temperature Range | Ambient to 300 °C |
| Max Temp Error | ±0.5 °C |
| Heating Rates | 50 °C/h, 120 °C/h, or user-defined between 50–120 °C/h |
| Deformation Range | 0–10 mm |
| Deformation Accuracy | ±0.005 mm |
| Resolution | 0.001 mm |
| Span Lengths | 64 mm and 100 mm |
| Thermal Medium | Methyl silicone oil or transformer oil (user-supplied) |
| Cooling | Natural cooling above 150 °C |
| Safety Protections | Dual hardware/software temperature limit switches, automatic test termination, administrator password lock |
| Compliance | GB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648 |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | XRW-300A3 |
| Temperature Range | 50–300 °C |
| Heating Rate Options | 120 °C/h and 50 °C/h |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.01 °C |
| Specimen Stations | 3 |
| Deflection Measurement | Digital micrometer with 0.001 mm resolution and 0–13 mm range |
| Support Span Options | 64 mm and 100 mm (ASTM-compliant adjustable) |
| Heating Medium | Methyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt) |
| Control Method | Fuzzy PID + PWM modulation |
| Data Acquisition | 7 samples/sec, 4–8 channels per sample |
| Human-Machine Interface | 7-inch capacitive color touchscreen with bilingual (EN/CN) OS |
| Compliance Standards | GB/T 1633, GB/T 1634.1–1634.3, GB/T 8802, ISO 2507, ISO 75, ISO 306, ASTM D1525, ASTM D648 |
| Brand | Zhonglu |
|---|---|
| Model | TGA-1250Q |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Temperature Range | Ambient to 1350 °C |
| Temperature Accuracy | ±0.01 °C |
| Temperature Resolution | 0.1 °C |
| Dynamic Weighing Range | 0.01 mg to 30 g |
| Balance Sensitivity | 0.1 μg |
| Mass Accuracy | ±0.00001 g |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 30 g |
| Baseline Repeatability | 25 ppm/10 °C |
| Baseline Drift | 25 ppm/10 °C |
| Atmosphere Control | Dual-gas inlet with mass flow control (inert, oxidizing, reducing, static/dynamic) |
| Cooling Time | ≤15 min (1000 °C → 100 °C) |
| Data Interface | RS-232 |
| Compliance | Patented in China (CN Patent No. disclosed upon request) |
Show next