Empowering Scientific Discovery

Shanghai Zhonglu Industrial Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
ModelDS C--500ARD
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Temperature RangeAmbient to 500 °C
Heating Rate0.1–80 °C/min
Temperature Repeatability±0.1 °C
Temperature Accuracy±0.1 °C
Temperature Resolution0.01 °C
Sample Capacity1
DSC Signal Range0 to ±200 mW / 0 to ±500 mW
Atmosphere ControlDual-gas auto-switching (N₂/Ar)
Display10.1-inch 24-bit color industrial touchscreen PC
Data InterfacesUSB 2.0, RS-232
Calibration StandardsIndium (In), Tin (Sn), α-Al₂O₃ reference material
ComplianceISO 11357, GB/T 19466, ASTM D3417
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelXRW-300A6
Temperature Range50–300 °C
Heating Rates120 °C/h or 50 °C/h (user-selectable)
Temperature Accuracy±0.5 °C
Temperature Resolution0.01 °C
Deflection MeasurementDigital micrometer with 0.001 mm resolution, 0–13 mm range
Specimen Span64 mm or 100 mm (ASTM-compliant adjustable)
Sample Stations6 independent test positions
Heating MediumMethyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt, supplied separately)
Control AlgorithmFuzzy PID with PWM output
Data Acquisition Rate7 samples/second per channel (4–8 channels simultaneously)
Human-Machine Interface7-inch capacitive color touchscreen, bilingual (English/Chinese) OS
Power Supply220 V AC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
ModelDSC-500ARD
TypeDifferential Scanning Calorimeter (DSC)
OriginShanghai, China
ManufacturerZhonglu Instrument Co., Ltd.
Temperature RangeAmbient to 500 °C
Heating Rate0.1–80 °C/min
Temperature Accuracy±0.1 °C
Temperature Repeatability±0.1 °C
Temperature Resolution0.01 °C
Sample Capacity1 position
DSC Signal Range0 to ±200 mW / 0 to ±500 mW
Atmosphere ControlDual-gas automatic switching (e.g., N₂/air)
Display10.1″ industrial-grade capacitive touchscreen (24-bit color)
Data InterfacesUSB 2.0, RS-232
ComplianceISO 11357, GB/T 19466, ASTM D3417
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDifferential Thermal Analysis (DTA)
ModelDTA-1350
Temperature RangeRT to 1350 °C
Temperature Accuracy±0.1 °C
Temperature Precision±0.1 °C
Temperature Stability±0.1 °C
Heating/Cooling Rate0.1–100 K/min
DTA Signal Range0–±2000 µV
DTA Sensitivity0.01 µV
Temperature Resolution0.01 °C
Control MethodPID-based Programmable Temperature Control
Data InterfaceUSB 2.0
Display7-inch 24-bit color capacitive touchscreen
Sensor MaterialCorrosion- and oxidation-resistant alloy
Atmosphere ControlAutomated internal gas switching
Calibration StandardCertified Sn reference material included
ComplianceASTM E794, ISO 11357-1, GB/T 19466.1–2004
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
ModelJLD-2000I
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
PriceUSD 2,800 (FOB Shanghai)
Extraction Capacity2000 mL
Heating Power500 W
Max Heating Temperature300 °C
Analytical Balance Range0–100 g
Readability0.0001 g
Vacuum Drying Chamber Temp RangeRT+10 to 250 °C
Vacuum Level≤133 Pa
Compliance StandardsGB/T 29848-2013, IEC 62788-1-6, ASTM D2765, ISO 10147:2011, CQC 3307-2013
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelDSC-500ARD
PriceUSD 4,200 (approx.)
Temperature RangeAmbient to 500 °C
Heating Rate0.1–80 °C/min
Temperature Repeatability±0.1 °C
Temperature Accuracy±0.1 °C
Sample Capacity1
Temperature Resolution0.01 °C
DSC Signal Range0 to ±200 mW / 0 to ±500 mW
Atmosphere ControlDual-gas automatic switching
Display10.1-inch 24-bit color industrial touchscreen PC
Data InterfacesUSB 2.0, RS-232
Calibration StandardsIndium (In) and Tin (Sn), certified reference materials included
ComplianceISO 11357, GB/T 19466, ASTM D3417
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelDSC-500ARD
PriceUSD 4,200 (approx.)
Temperature RangeAmbient to 500 °C ±0.1 °C
Heating Rate0.1–80 °C/min
Temperature Repeatability±0.1 °C
Temperature Accuracy±0.1 °C
Sample Capacity1
Temperature Resolution0.01 °C
DSC Signal Range±200 mW / ±500 mW
Atmosphere ControlDual-gas automatic switching
Display10.1-inch 24-bit color industrial touchscreen PC
Data InterfacesUSB, RS-232
Calibration StandardsIndium and Tin reference materials included
ComplianceISO 11357, GB/T 19466, ASTM D3417
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Zhonglu
OriginShanghai, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelMFI-1221
Test MethodMass Flow Rate (MFR) & Volume Flow Rate (MVR)
Temperature Range100–450 °C
Temperature Accuracy±0.2 °C
Temperature Resolution0.1 °C
Temperature Recovery Time≤2 min after charge
Die Dimensions2.095 mm ±0.005 mm ID, 8.000 mm ±0.025 mm length
Barrel ID9.550 mm ±0.007 mm
Piston Displacement Resolution0.002 mm
Piston Accuracy±0.02 mm
Load ApplicationManual
Display5-inch HD color TFT touchscreen (bilingual: EN/CN)
Power Supply220 VAC ±10%, 50 Hz, 0.5 kVA
Weight~25 kg (main unit), ~25 kg (accessories)
ComplianceGB/T 3682–2018, ASTM D1238, ISO 1133:2005, BS 2782
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
ModelXRW-300B4
OriginShanghai, China
ManufacturerZhonglu Instrument Co., Ltd.
ApplicationHeat deflection temperature (HDT) and Vicat softening temperature (VST) testing of thermoplastics, thermosets, fiber-reinforced composites, laminates, and electrical insulating materials
Standards ComplianceGB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648
Temperature Control RangeAmbient to 300 °C
Max. Temp. Deviation±0.5 °C
Heating Rates50 °C/h or 120 °C/h (adjustable between 50–120 °C/h)
No. of Test Stations4
Deflection Measurement Range0–10 mm
Deflection Accuracy±0.005 mm
Resolution0.001 mm
Span Lengths64 mm or 100 mm
Thermal Expansion Coefficient of Test Frame<0.005 /100 °C
Temperature Sensor TypeHigh-stability platinum RTD
Displacement SensorOptical-grating digital micrometer
Control MethodPC-based software with real-time curve display and automated reporting
Safety ProtectionsDual hardware/software temperature limit switches (30 A Korean thermal cutoff), end-of-test auto-halt, administrator password lockout
Heating Power4000 W
Heat Transfer MediumMethyl silicone oil or transformer oil
CoolingNatural convection above 150 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
ModelXRW-300C6
OriginShanghai, China
ManufacturerZhonglu Instrument Co., Ltd.
Control Interface7-inch touchscreen + PC software
Test Frames6
Temperature RangeAmbient to 300 °C
Max Temp Error±0.5 °C
Heating Rates50 °C/h, 120 °C/h, or user-defined between 50–120 °C/h
Deformation Range0–10 mm
Deformation Accuracy±0.005 mm
Resolution0.001 mm
Span Lengths64 mm and 100 mm
Thermal MediumMethyl silicone oil or transformer oil (user-supplied)
CoolingNatural cooling above 150 °C
Safety ProtectionsDual hardware/software temperature limit switches, automatic test termination, administrator password lock
ComplianceGB/T 1633, GB/T 8802, GB/T 1634, ISO 2507, ISO 75, ISO 306, ASTM D 1525, ASTM D 648
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelXRW-300A3
Temperature Range50–300 °C
Heating Rate Options120 °C/h and 50 °C/h
Temperature Accuracy±0.5 °C
Temperature Resolution0.01 °C
Specimen Stations3
Deflection MeasurementDigital micrometer with 0.001 mm resolution and 0–13 mm range
Support Span Options64 mm and 100 mm (ASTM-compliant adjustable)
Heating MediumMethyl silicone oil (flash point >300 °C, kinematic viscosity <200 cSt)
Control MethodFuzzy PID + PWM modulation
Data Acquisition7 samples/sec, 4–8 channels per sample
Human-Machine Interface7-inch capacitive color touchscreen with bilingual (EN/CN) OS
Compliance StandardsGB/T 1633, GB/T 1634.1–1634.3, GB/T 8802, ISO 2507, ISO 75, ISO 306, ASTM D1525, ASTM D648
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhonglu
ModelTGA-1250Q
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Temperature RangeAmbient to 1350 °C
Temperature Accuracy±0.01 °C
Temperature Resolution0.1 °C
Dynamic Weighing Range0.01 mg to 30 g
Balance Sensitivity0.1 μg
Mass Accuracy±0.00001 g
Heating/Cooling Rate1–80 °C/min
Maximum Sample Mass30 g
Baseline Repeatability25 ppm/10 °C
Baseline Drift25 ppm/10 °C
Atmosphere ControlDual-gas inlet with mass flow control (inert, oxidizing, reducing, static/dynamic)
Cooling Time≤15 min (1000 °C → 100 °C)
Data InterfaceRS-232
CompliancePatented in China (CN Patent No. disclosed upon request)