| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCT-3 |
| Temperature Range | Ambient to 1450 °C |
| Heating Rate | 0.1–100 °C/min (user-definable) |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Control | Dual-channel mass flow controller (MFC) |
| DSC Range | ±1 mW to ±500 mW |
| DSC Sensitivity | ±0.1 μW |
| TG Measurement Range | 1–200 mg |
| TG Resolution | 0.1 μg |
| TG Noise | <0.1 μg |
| Vacuum Capability | 2.5×10⁻² Pa (with optional vacuum pump) |
| DTA Range | ±10 μV to ±2000 μV |
| DTA Resolution | 0.01 μV |
| Crucible Options | Al₂O₃ (0.06 mL / 0.12 mL), Al, graphite, quartz, Pt |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-STA-002 |
| Coupling Technique | Thermogravimetry–Differential Scanning Calorimetry (TG-DSC) |
| Heating Rate | 0.1–80 °C/min |
| Temperature Range | Ambient to 1150 °C |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 2 g (expandable to 30 g) |
| Atmosphere Control | Dual-gas channel with automatic switching (N₂ standard) |
| Flow Rate | 0–300 mL/min |
| TG Resolution | 10 µg |
| TG Dynamic Range | 1 mg–2 g |
| DSC Range | ±700 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy & Repeatability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | 15 min |
| Control Modes | Programmable heating, isothermal hold, and cooling |
| Data Interface | Standard USB |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 470 × 580 × 460 mm |
| Display | 7-inch 24-bit color LCD touchscreen |
| Core Processor | 32-bit ARM Cortex-M3 |
| ADC | 24-bit, 4-channel synchronous sampling for TG, DSC, and T signals |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS-STA-002 (Simultaneous TGA-DTA Analyzer) |
| Temperature Range | Ambient to 1150 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 2 g |
| Atmosphere | Nitrogen (dual-gas auto-switching, 0–300 mL/min, ≤0.5 MPa) |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HS-STA-302 |
| Price | Upon Request |
| Temperature Range | RT to 1300 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 3 g |
| Atmosphere | Nitrogen (dual-gas automatic switching, 0–300 mL/min, ≤0.5 MPa) |
| Brand | Huicheng Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HCYQ-STA-1550 |
| Heating Rate | 0.1–100 °C/min |
| Temperature Range | Ambient to 1550 °C |
| Temperature Stability | ±0.1 °C |
| Max Sample Mass | 5 g |
| Atmosphere Options | N₂, O₂ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 2500 Regulus |
| Heating Rate | 0–100 °C/min |
| Temperature Range | RT to 1100 °C (standard furnace) / RT to 1600 °C (high-temperature furnace) |
| Temperature Stability | ±0.3 K |
| Maximum Sample Mass | 250 mg |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum (dynamic or static) |
| Gas Control | Integrated Mass Flow Controllers (MFCs), software-regulated |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 449 F3 Jupiter |
| Temperature Range | −150 to 2400 °C |
| Heating Rate | 0–50 °C/min (standard) |
| Temperature Stability | ±0.3 K |
| Maximum Sample Mass | 35 g |
| Balance Resolution | 0.1 µg |
| Vacuum Level | 10⁻⁴ mbar |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Optional Modules | TMDSC, Tau-R® Cp Calibration, BeFlat® Baseline Optimization, ASC Auto-sampler (20 positions), Coupling to FTIR/MS/GC-MS, Steam Furnace, Corrosive Gas Kit |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 509 Jupiter Classic |
| Temperature Range | RT to 1600 °C |
| Heating Rate | 0.001–50 °C/min |
| Max Sample Mass | 35 g |
| Atmosphere Options | Inert, Oxidizing, Static, Dynamic, Vacuum, Corrosive (optional) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | STA 509 Jupiter Supreme |
| Temperature Range | –150 °C to 2000 °C |
| Maximum Sample Mass | 5 g |
| Atmosphere Options | Inert, Oxidizing, Static, Dynamic, Vacuum, Corrosive (optional) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA 8000 |
| Pricing | Upon Request |
| Temperature Range | −150 °C to 1600 °C |
| Heating Rate | 0.01–100 °C/min |
| Temperature Stability | ±0.01 °C (at isothermal hold) |
| Maximum Sample Mass | 2 g (standard), up to 5 g (optional crucible) |
| Atmosphere Control | Dual-gas MFC with programmable switching (N₂, O₂, Ar, He, air, forming gas) |
| Balance Resolution | 0.1 µg |
| DSC Sensitivity | < 0.1 µW |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | STA6000 |
| Pricing | Upon Request |
| Heating Rate (°C/min) | Up to 100 |
| Temperature Range (°C) | −150 to 1500 |
| Temperature Stability | ±0.01 °C |
| Maximum Sample Weight (g) | 2000 |
| Atmosphere Control | Dual-gas MFC with Auto-Switching (Inert, Oxidizing, Reducing) |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Manufacturer |
| Model | STA-790 |
| Temperature Range | Ambient to 1300 °C / 1600 °C |
| Heating Rate | 0.01–50 °C/min |
| Thermogravimetric (TGA) Range | ±200 mg / ±1000 mg |
| TGA Resolution | 0.02 µg |
| DSC Resolution | 1 µW |
| Atmosphere Control | Dual independent mass-flow-controlled gas lines with software-programmable switching |
| Crucible Options | Al₂O₃, quartz, BN (optional) |
| Furnace Cooling | Integrated water-cooled furnace housing |
| Power Supply | 220 V, 50/60 Hz |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | TG-DTA8122 |
| Temperature Range | Ambient to 1500 °C |
| Measurement Principle | Horizontal Dual-Cantilever Differential DTA with Integrated Thermogravimetry (TG) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZRY-1A & ZRY-2A |
| Price Range | USD 14,000–42,000 (FOB Shanghai) |
| Heating Rate | 0.1–50 °C/min |
| Temperature Range | Ambient to 1450 °C |
| Temperature Stability | ±1.5 °C |
| Maximum Sample Mass | 2 g |
| Atmosphere Options | Inert, Oxidizing, Static, Dynamic |