Single Wavelength XRF Spectrometer
Filter
Showing all 11 results
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | DUBHE-1610 |
| Detection Limit (LLD) | 0.4 ppm (S) |
| Measurement Range | 0.4 ppm – 5 wt% |
| Analysis Time | 60–300 s |
| Repeatability | ≤0.2 ppm (at 2 ppm S), ≤0.5 ppm (at 10 ppm S), ≤2.5 ppm (at 50 ppm S) |
| Excitation Line | Cr Kα (5.41 keV) |
| Optical Configuration | Dual Polycapillary Focusing Monochromator + Full-Focus Bent Crystal Analyzer |
| Sample Preparation | ESP (Easy Sample Prepare) System |
| Operating Mode | Benchtop, Air-path, No Gas or Solvent Consumption |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | DUBHE-1710 |
| Detection Limit (Cl) | 0.1 ppm |
| Measurement Range | 0.1 ppm – 5 wt% |
| Analysis Time | 60–300 s |
| Repeatability | ≤0.2 ppm (at 1 ppm Cl), ≤0.5 ppm (at 5 ppm Cl), ≤2.5 ppm (at 50 ppm Cl) |
| Sample Prep Time | <10 s |
| Operating Warm-up | ≤10 min |
| Cost per Sample | <USD 0.55 (excl. labor) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MEGREZ-A |
| Excitation | Dual X-ray tube sources with polycapillary-focusing monochromators |
| Detection Principle | Energy-dispersive X-ray fluorescence (ED-XRF) with monochromatic excitation |
| Elemental Range | Z ≥ 5 (Boron and heavier elements) |
| Detection Limit (Heavy Metals) | As low as 0.05 mg/kg (matrix-dependent) |
| Quantification Method | Fast fundamental parameters (FP) algorithm with minimal or zero calibration standards |
| Compliance | Designed for ISO 8258, ASTM E1621, and GB/T 30091–2013 compliant workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-CEMII |
| Price Range | USD 70,000 – 140,000 |
| Compliance | GB/T 176–2008 |
| Elements Analyzed | Na, Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn |
| Detection Principle | Wavelength-Dispersive XRF (WDXRF) with High-Flux Doubly Curved Crystal Spectrometer (HF DCCS) and Secondary Target Excitation |
| Sample Form | Solid powders (pressed pellets or fused beads) |
| Vacuum/Atmosphere | Ambient air operation (no vacuum pump or He purge required) |
| Cooling | Peltier-cooled detector (no liquid nitrogen) |
| Stability | Ready for measurement within 3 minutes after power-on |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-LEII |
| Detection Range | Na–Ti (extendable to C, N, O, F) |
| Light Element LLDs | S ≤ 0.2 ppm, Cl ≤ 0.1 ppm, Si ≤ 0.8 ppm |
| Excitation | Monochromatized Wavelength-Selective X-ray Beam via Focusing Polycapillary Optics |
| Optical Architecture | Fixed X-Ray Path System (XFS) |
| Sample Form | Solid, Liquid, or Powder in Disposable Cups/Membranes |
| Compliance | Designed for ASTM D2622, D4294, D7039, ISO 8754, IP 287, and USP <233> elemental impurity testing workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-MINI |
| Detection Limit (S) | 0.5 ppm (300 s) |
| Detection Limit (Cl) | 0.3 ppm (300 s) |
| Quantification Range | 0.5 ppm – 5% |
| Analysis Time | 60–300 s |
| Repeatability | RSD ≤ 3% @ 10 ppm S, RSD ≤ 1.5% @ 1000 ppm S |
| Dimensions | 350 mm × 230 mm × 370 mm |
| Weight | 12.5 kg |
| Power Consumption | 80 W |
| Operating Temperature | 5–40 °C |
| Battery Life | >4 h |
| Compliance | ASTM D7039, ASTM D7536, ISO 20884, ISO 15597 |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | MERAK-SC |
| Excitation | Monochromatic Focused X-ray (Johansson-type DCC crystal) |
| Detection | Ultra-thin Graphene-window Silicon Drift Detector (SDD) |
| Elemental Range | F–Cl (light elements), K–Zn (transition metals) |
| LOD (F) | 0.15 wt% (300 s, aqueous matrix) |
| LOD (Al–Cl) | 0.0002–0.005 wt% (300 s) |
| Sample Types | Liquids, powders, solids |
| Geometry | Top-illumination |
| Sample Rotation | Motorized, software-controlled |
| Temperature Control | 24 ± 0.3 °C |
| Analysis Time | 30–300 s per sample |
| Stability | < ±3% intensity drift over 24 h |
| Quantification Engine | Fast FP 2.0 fundamental parameters software |
| Compliance | Designed for ISO 8258 (control charts), ASTM E1621 (ED-XRF for cement), USP <233> (elemental impurities), and GLP/GMP-aligned data integrity workflows |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MERAK-TINY |
| Pricing | Upon Request |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-ECO |
| Element Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | ≤0.3 mg/kg, RSD <15% |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Method | Single-wavelength excitation + energy-dispersive detection |
| Software | Fast FP® quantitative engine with matrix-adaptive modeling |
| Optional Preconcentration | Heavy Metal Enrichment Tape (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Weight | 7.5 kg |
| Dimensions | 370 × 290 × 190 mm |
| Operation | Ambient air, no vacuum/gas required |
| Sample Interface | Motorized sample rotation stage |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-HE & PHECDA-HES |
| Detection Limit (soil matrix, 300 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Repeatability (Cd, soil) | RSD < 15% at 0.3 mg/kg |
| Elemental Range | Mg–U |
| Sample Types | Solid, liquid, powder, viscous |
| Detector | High-performance Silicon Drift Detector (SDD) |
| Excitation Principle | Monochromatic focused excitation via doubly curved crystal (DCC) |
| Software | Fast FP® 2.0 quantitative engine |
| Auto-sampler | 30+ positions (PHECDA-HES) |
| HMET® integration for aqueous samples (detection limit | 1–3 µg/L) |
| Brand | Anchor Wisdom |
|---|---|
| Origin | Beijing, China |
| Model | PHECDA-PRO |
| Excitation Principle | Monochromatic Focused Excitation (using doubly curved crystal monochromator) |
| Detection Principle | Energy-Dispersive XRF (ED-XRF) |
| Elemental Range | Mg–U |
| LOD (soil matrix, 600 s) | Cd: 0.06 mg/kg, Pb: 0.4 mg/kg, Cr: 1.0 mg/kg |
| Precision (RSD) | Cd <15% at 0.3 mg/kg (soil, 600 s) |
| Sample Types | Solids, powders, slurries, liquids (with HMET® membrane enrichment), filters (e.g., PM₂.₅), and viscous matrices |
| Detector | High-performance silicon drift detector (SDD) with optimized active area and energy resolution |
| Software | Fast FP® quantitative engine (fundamental parameters-based, matrix-adaptive, standard-free or minimal-standard calibration) |
| Optional Enhancement | Heavy Metal Enrichment Technology (HMET®) for aqueous samples (LOD: 1–3 µg/L) |
| Portability | 8.7 kg |