Skin Testers
Filter
Showing all 16 results
| [Brand | ANTSCI |
|---|---|
| Origin | Italy |
| Model | Skin-SP |
| Probe Count | 6 external + 1 integrated sebum sensor |
| Moisture Range | 0–100 u.c., ±5% |
| Sebum Range | 0–100 u.c., ±5% |
| pH Range | 2–12, ±1% |
| Melanin Range | 0–100, ±5% |
| Elasticity Range | 0–50, ±5% |
| Temperature Range | 20–40 °C, ±0.1 °C |
| Measurement Time | 4–10 s |
| Display | 7″ color LCD touch screen |
| Printer | thermal, 34-column report output |
| Power | 12 V DC / 3.5 A, max. 60 W |
| Dimensions | 450 × 260 × 120 mm |
| Weight | 2.8 kg |
| Compliance | CE] |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-GP1 |
| Measurement Principle | Dual-finger-type quasi-static compression with real-time viscoelastic force feedback |
| Sensor Type | Lightweight, bidirectional tactile probes with adjustable clamping displacement and dwell time |
| Output Parameters | Maximum Stress (kPa), Skin Hardness Index, Elastic Recoil Ratio (%), Viscoelastic Relaxation Time Constant (s), Collagen Aging Index (unitless derived metric), Initial Rebound Velocity (mm/s), Sagging Index (normalized strain recovery deficit) |
| Compliance | Designed for GLP-aligned dermatological research workflows |
| Software Interface | PC-based acquisition with waveform visualization, timestamped data export (CSV, PNG), and multi-point protocol storage |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-TZ1 |
| Measurement Principle | Low-frequency AC impedance |
| Impedance Range | 0.5–99 kΩ |
| Phase Angle Range | 0–90° |
| Repeatability | ±2% (0.1–10 kΩ), ±1% (10–99 kΩ) |
| Excitation Voltage | 5 V DC |
| Test Frequency | 12 Hz |
| Electrodes | Ag/AgCl (donor side), Ag (receiver side) |
| Display | 65 × 15 mm LCD |
| Dimensions | 190 × 60 × 200 mm |
| Power Supply | 6 V DC (battery-operated) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASA-03RXD |
| Imaging Principle | CCD-based 30° parallel-light profilometry |
| Sample Type | Silicone replica |
| Quantitative Output | Wrinkle count, volume (triangular cross-section model), depth, width, area ratio, texture parameters (Rz, Rt), 3D surface visualization |
| Compliance | JSCA Guideline for Evaluation of Anti-Wrinkle Products |
| Software Platform | Windows 10 native application with calibration, edge enhancement, and XY/depth conversion modules |
| Optional Modules | Sebum measurement kit (ASS-001 SEBU patch + absorbance analysis software) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASA-MX100 |
| Measurement Principle | Conductivity-based Corneal Hydration & Transepidermal Electrical Resistance (TEER) |
| Probe Types | C3D-MX (3D skin models), R2-MX (scalp), T4-MX (nail) |
| Measurement Time | 5 s per reading |
| Electrode Configuration | Separated excitation/detection electrodes |
| Output Interface | RS-232 digital port |
| Calibration | Fully digital one-button calibration |
| Compliance | Designed for GLP-compliant dermatological research and cosmetic efficacy testing |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASP-02 |
| Measurement Range | 0–9 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.2 pH |
| Response Time | ≤10 s |
| Calibration | Two-point with pH 4.0 and pH 7.0 standard buffers |
| Operating Temperature | 0–50 °C |
| Storage Environment | 5–50 °C, 5–85% RH (non-condensing) |
| Power Supply | 2 × AA alkaline batteries |
| Main Unit Dimensions | 122 × 80 × 33.5 mm (H×W×D) |
| Main Unit Weight | ~200 g |
| Electrode Dimensions | 135 mm length × φ12 mm diameter |
| Cable Length | 1 m |
| Electrode Weight | ~60 g |
| Sample Interface | Flat-surface combination pH electrode for direct skin contact |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-VT100RS |
| Measurement Principle | Closed-chamber dynamic humidity gradient analysis |
| TEWL Range | 0–300 g/m²/h |
| Resolution | 0.1 g/m²/h |
| Measurement Time | 5–14 s |
| Probe Aperture Options | 6, 8, 10, or 12 mm (DIP-switch configurable) |
| Dimensions | 165 × 70 × 28 mm |
| Weight | 200 g |
| Power Supply | AC adapter or AA batteries |
| Environmental Monitoring | Integrated temperature & relative humidity sensors |
| Data Output | RS-232 serial interface |
| Sample Types | Human skin (in vivo), excised animal skin (rat, pig, rabbit), 3D reconstructed human epidermis (RHE), and cultured skin models |
| Brand | ASE |
|---|---|
| Origin | Japan |
| Model | LHT-04 |
| Measurement Principle | Ventilated Capsule Method |
| Measurement Range | 0.00–3.00 mg/cm²/min (at 30 °C, 40 % RH) |
| Accuracy | ±10 % |
| Response Time | 1 s |
| Measurement Area | 1 cm² |
| Channel Count | 1 |
| Probe Length | 0.9 m (standard), up to 1.2 m (optional) |
| Data Logging Duration | 4 h |
| Power Supply | 2 × AA batteries |
| Operating Temperature | 15–35 °C |
| Operating Humidity | 40–60 % RH |
| Dimensions (W×H×D) | 76 × 35 × 135 mm |
| Weight | 350 g |
| Compliance | Designed for ISO 9241-305 (human thermal comfort), ASTM E1980 (sweat rate in physiological testing), and GLP-aligned data integrity workflows |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CM825-MDD |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | VC20plus |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Visioface1000D |
| Pricing | Upon Request |
| Brand | Moon-BJ |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UV-2000S |
| Price Range | USD 14,000 – 28,000 |
| Brand | APEL |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M2HA-350X |
| Pricing | Upon Request |
| Rated Voltage/Current | AC125V/1–50 mA, AC250V/1–50 mA, DC5V/1–50 mA, DC48V/1–50 mA |
| Electrical Life | ≥3,000 cycles (at rated load) |
| Trip Temperature | OFF at ≥350°C (±5°C), ON at ≤325°C (±5°C) |
| Differential | 25 K |
| Dimensions | 56 × 17 × 9 mm |
| Housing Material | Alumina (Al₂O₃) ceramic |
| Max. Ambient Operating Temperature | 400°C |
| Application | Overheat protection for heating elements and electronic control units |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | Mono602® |
| Compliance | ISO 23698:2024, ISO 24442, BS EN 62471:2008 |
| Spectral Range | 290–400 nm |
| Measurement Time per Sample | 3–4 s |
| Operating Temperature | 15–35 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Power Supply | 110–240 VAC, 50/60 Hz, max. 7 A |
| Dimensions (H×W×L) | 52.4 × 40.6 × 50.8 cm |
| Weight | 29 kg |
| Fiber Optic Probe | Bifurcated bundle with integrated contact probe, 1.8 m length |
| UV Exposure Level | Below ACGIH TLV® and occupational exposure limits |
| Footswitch & Keyboard Control | Included |
| Software | HDRSplus™ v5.x (Windows-based, FDA 21 CFR Part 11 ready) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | Poly602® |
| Compliance | ISO 23698:2024, ISO 24442, BS EN 62471:2008, ACGIH UV Exposure Guidelines |
| Spectral Range | 320–400 nm |
| Operating Temperature | 15–35 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Power Supply | 110–240 VAC, 50/60 Hz, max 7 A |
| Interface | USB |
| Dimensions (H×W×L) | 26.2 × 40.6 × 40.6 cm |
| Clear Rear Clearance Required | 8 cm |
| Weight | 15.4 kg |
| Fiber Optic Probe | Bifurcated bundle with integrated contact probe, 1.8 m length |
| Measurement Time per Sample | ~3–4 s |
| Throughput | 10 subjects × 8 products = ~8 hours |
| UV Exposure Level | Below occupational exposure limits (ACGIH/IEC 62471) |
| [Brand | Moon-BJ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Medical-Grade Dermatological Imaging System |
| Model | VISIA 7 |
| Light Sources | Standard White Light & UV-A (365 nm) |
| Analyzed Parameters | 8 Quantitative Skin Features (Pigmentation, Pores, Wrinkles, Texture, UV Spots, Porphyry, Red Areas, Brown Spots) |
| Database Comparison | Age-, Gender-, and Ethnicity-Matched Reference Norms |
| Advanced Capabilities | Real-Time Zoom, 3D Surface Viewer, Simulated Aging Algorithm, Eyelash Length Measurement |
| Compliance | Designed for Clinical Dermatology and Aesthetic Practice Environments] |