| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe 360 |
| Resolution | 20 nm |
| Field of View | 200 × 200 µm² |
| Category | Super-Resolution Microscope (SMLM) |
| Technique | Single-Molecule Localization Microscopy (SMLM) with 3D axial localization |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe M90 |
| Scan Field of View | 150 µm × 150 µm (with 100× objective) |
| Imaging Speed | up to 330 fps at 512 × 512 pixels |
| Objectives Supported | 60×, 100× |
| Multicolor Capability | Simultaneous 4-channel imaging |
| TIRF Angle Calibration Accuracy | <1.2% error |
| Illumination Modes | TIRF / HILO / Epi (software-switchable) |
| Depth Imaging | Z-stack compatible |
| Dichroic Stability | Precision-engineered cubes for long-term chromatic alignment |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe MN180 |
| Imaging Modes | PALM, STORM, smFRET, PAINT, SPT |
| Illumination Configurations | Epi, TIRF, HILO |
| Lateral Resolution | 20 nm (XY), Axial Resolution: 50 nm (Z) |
| Field of View | 150 × 150 µm² |
| Compatibility | Modular integration via C-mount on inverted fluorescence microscopes |
| Software Control | Fully automated acquisition for TIRF/PALM/STORM/SPT/smFRET |
| Compatible Systems | Confocal, Spinning Disk, Widefield, SIM, STED |
| Dye Compatibility | Atto 488, WGA-AF®488, AF®532, CF®532, Cy3b, AF®555, AF®594, CF®555, AF®568, CF®568, Cy5, MemBrite™ 568, TMR, AF®647, CF®647, AF®680, CF®680, MemBrite™ 640, Actin-stain 670, SiR647 |
| Brand | Abbelight |
|---|---|
| Origin | France |
| Model | SAFe MN360 |
| Technology | Structured Illumination Microscopy (SIM) & Single-Molecule Localization Microscopy (SMLM) |
| Resolution | 15 nm (x, y, z) |
| Field of View | 200 × 200 µm² |
| Imaging Modes | PALM, STORM, PAINT, smFRET, SPT |
| Illumination Modes | Epi, TIRF, HILO |
| Depth Imaging Capability | 1.2 µm per acquisition (up to 10 µm total depth) |
| Multicolor Capacity | Up to 4 simultaneous channels |
| Drift Correction | Real-time hardware-based |
| Live-Cell Compatibility | Yes |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible metadata logging |
| Brand | Accurion |
|---|---|
| Origin | Germany |
| Model | Accurion UltraBAM Brewster Angle Microscope |
| Interface Compatibility | Standard Langmuir Trough Systems |
| Imaging Speed | 20–35 fps |
| Lateral Resolution | ≤2 µm |
| Brewster Angle Range | 52°–57° |
| Vertical Positioning | Motorized Precision Z-Stage |
| Vibration Isolation | Active Optical Table Integration |
| Quantitative Reflectivity Calibration | Yes |
| Anisotropy Detection | Motorized Rotating Analyzer |
| Field of View | Wide-Area (Compatible with Large-Surface Langmuir Troughs) |
| Data Format | AVI + Metadata-Embedded TIFF (Including Trough Parameters) |
| Brand | Airy |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Polar-SIM |
| Pricing | Upon Request |
| Technology | Structured Illumination Microscopy (SIM) |
| Excitation Wavelength | Customizable |
| Resolution | XY: 85 nm (raw), <60 nm (algorithm-enhanced) |
| Z | 300 nm |
| Field of View | 130 × 104 µm (at 100× objective) |
| Imaging Speed | 565 fps @ 128 × 4096 |
| Eyepiece-Compatible Platforms | Nikon Ti2-E or Olympus IX83 (selectable) |
| Objectives | Apo 60×/NA=1.49, Apo 100×/NA=1.49, or NA=1.7 immersion objectives (optional) |
| Light Source | Customizable LED/Laser Engine |
| Brand | CSR Biotech |
|---|---|
| Origin | Guangdong, China |
| Model | Cell Xtreme |
| Technology | Structured Illumination Microscopy (SIM) & Multi-Illumination Optical Diffraction Tomography (MI-ODT) |
| Resolution | XY: 60 nm, Z: 200 nm |
| Field of View | MI-ODT: up to 138 × 138 µm @100× |
| MI-SIM | up to 150 × 150 µm @100× |
| Imaging Speed | up to 25 fps @16-bit, 4608 × 4608 pixels |
| Eyepiece Options | Olympus IX85 / IX83 / Nikon Ti2-E |
| Objective | Apo 100×/1.5 Oil |
| Light Source | Multi-color coupled laser illumination system |
| Brand | Lyncee Tec |
|---|---|
| Origin | Switzerland |
| Model | DHM-T1000 / DHM-T2100 |
| Imaging Speed | 190 fps |
| Type | Transmission-mode Digital Holographic Microscope |
| Application Domain | Quantitative Live-Cell Imaging, Biophysical Metrology, Transparent Sample Characterization |
| Brand | Micro-Field / Guangzhou Micro-field Optical Technology Co., Ltd. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HM-SR-01 |
| Imaging Modality | dSTORM (direct Stochastic Optical Reconstruction Microscopy) & TIRF (Total Internal Reflection Fluorescence) |
| Objectives | Plan-Apochromat 40×/0.95 (WD: 0.25–0.16 mm) |
| Apochromat 100×/1.45 Oil (WD | 0.13 mm) |
| Excitation Lasers | 405 nm (60 mW), 432 nm (80 mW), 488 nm (20 mW), 561 nm (80 mW), 638 nm (60 mW) |
| Focus Stability | Active autofocus with ≤50 nm axial drift correction |
| Z-Stage | Closed-loop nanopositioning stage (150 µm travel, 0.8 nm resolution) |
| XY-Stage | Motorized stage (110 × 75 mm travel, ±1 µm repeatability) |
| Camera Interface | High-sensitivity scientific CMOS or EMCCD compatible |
| Dimensions | 840 × 345 × 750 mm |
| Brand | Nexcope |
|---|---|
| Model | NSR950 |
| Technology | Structured Illumination Microscopy (SIM) |
| Laser Wavelengths | 405 nm, 488 nm, 561 nm, 640 nm |
| Lateral Resolution | ≤86 nm (TIRF-SIM), ≤115 nm (3D-SIM) |
| Field of View | Square inscribed in Φ22 mm |
| Imaging Speed | 120 fps |
| Eyepieces | 10× (25 mm field number), EP 17.5 mm, diopter adjustment range −5 to +5 |
| Objectives | 10×, 20×, 40×, 60×, 100× |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | BC43 |
| Imaging Modes | Confocal, Widefield, Brightfield & Differential Phase Contrast (DPC) Transmission |
| Illumination Technology | Patented Borealis™ Uniform Illumination |
| Z-Stack Speed | ≥10× faster than point-scanning confocal systems |
| Software Platform | ANDOR Fusion (GPU-accelerated deconvolution, multi-position montage, hardware-synchronized 3D stitching) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Physical Design | Compact benchtop architecture with integrated vibration damping and optical sealing — no darkroom or optical table required |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | WITec alpha360 Raman Imaging Microscope |
| Pricing | Available Upon Request |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | M-SIM6000 |
| Pricing Range | USD 118,000 – 153,000 (FOB) |
| Technology | Structured Illumination Microscopy (SIM) |
| Lateral Resolution (XY) | 240 nm |
| Axial Resolution (Z) | 600 nm |
| Imaging Speed | 100 fps @ 2048 × 2048 |
| Eyepieces | High-eyepoint wide-field plan achromat PL10X/22 mm with adjustable diopter |
| Objectives | Long-working-distance plan semi-apochromat (4×, 10×, 20×, 40×, 60×) |
| Light Source | Independently controllable four-wavelength LED fluorescence illumination |
| Brand | VIYEE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ISTED Super-Resolution Microscope |
| STED Technology | Stimulated Emission Depletion |
| Excitation Laser Wavelengths | 405 nm / 488 nm / 561 nm (solid-state) / 640 nm |
| Resolution | Confocal Mode — Lateral 150 nm, Axial 300 nm |
| Field of View | 120 µm × 120 µm (with 100× oil immersion objective, NA ≥ 1.4) |
| Imaging Speed | 1 FPS at 512 × 512 pixels |
| Eyepieces | 10× wide-field |
| Objectives | 10×, 20×, 40×, 60× oil, 100× oil (NA ≥ 1.4) |
| Illumination | Transmitted LED ≥ 5 W |
| Detectors | ≥4 APD channels with ultra-low dark current and high photon detection efficiency |
| Scan Modes | X-Y, X-Y-T, X-Y-Z, X-Y-Z-T |
| Spectral Dispersion Accuracy | 10 nm |
| Stage | High-precision motorized stage (positioning accuracy < 0.7 µm) |
| Software Platform | Windows 10 Pro 64-bit, ≥64 GB RAM, ≥2 TB SSD |
| Image Acquisition & Analysis | 4-channel fluorescence imaging, up to 8192 × 8192 resolution, time-lapse acquisition, automated tile scanning, Z-stack acquisition, deconvolution, 3D reconstruction, AI-assisted cell segmentation, subcellular structure quantification, fluorescence co-localization analysis, interactive morphometric measurement |