Suspended Solids Analyzer
Filter
Showing all 19 results
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | S-730 |
| Instrument Type | Online Analyzer |
| Measurement Range | 0–30 g/L |
| Display | LCD |
| Units | g/L, mg/L, NTU |
| Resolution | 0.001 g/L or 1 mg/L |
| Accuracy | ±1.0% FS |
| Repeatability | ±1.0% FS |
| Ambient Temperature | −20 to +60 °C |
| Relative Humidity | (65 ± 20)% |
| Analog Output | 4–20 mA (750 Ω load) |
| Alarm Output | Dual SPDT relays |
| Digital Output | RS485 (optional) |
| Power Supply | AC 220 V ±10% or DC 24 V |
| Housing Material | SS316 |
| Process Temp. Range | 0–60 °C |
| Max. Pressure Rating | 1.0 MPa |
| Process Connection | 3/4″ NPT |
| IP Rating | IP68 |
| Installation Options | Immersion bracket or inline pipe insertion |
| Standard Cable | Shielded, 10 m |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IN-SS |
| Instrument Type | Portable |
| Detection Range | 1–600 mg/L |
| Standard Compliance | GB 13200-91 |
| Wavelength Range | 340–800 nm |
| Measurement Principle | Photometric Colorimetry |
| Repeatability | <0.5% |
| Stability | <0.5% |
| Wavelength Selection | Automatic |
| Operating System | Android-based UI |
| Display | 3.5-inch color LCD touchscreen |
| Absorbance Sensitivity | 0.001 AU |
| Environmental Operating Conditions | 0–50 °C, 0–90% RH (non-condensing) |
| Data Storage Capacity | >80,000 records |
| Connectivity | USB Type-C, Wi-Fi, Bluetooth, Mobile Hotspot |
| Battery | 5600 mAh rechargeable Li-ion |
| Continuous Operation Time | Up to 8 hours |
| Power Supply | 5 V DC |
| Dimensions | 180 × 80 × 70 mm |
| Weight | 700 g |
| Light Source | Imported cold-light LED (rated lifetime ≥100,000 h) |
| Dual Power Mode | AC adapter & internal battery |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Model | Dr-M1212P |
| Portability | Portable |
| Measurement Principle | Electrochemical & Optical (Nephelometric for Turbidity/Suspended Solids) |
| Display | 5-inch HD color capacitive touchscreen |
| Language Support | English & Chinese |
| Electrode Ports | 3 independent digital electrode slots |
| Electrode Interface | Plug-and-play digital electrodes with auto-recognition |
| Temperature Compensation | Automatic real-time compensation (0–50 °C) |
| Power Supply | Rechargeable Li-ion battery + USB Type-C AC adapter (dual-mode operation) |
| Data Storage | Up to 1,000,000 measurement records with timestamp, location (GPS optional), and electrode ID tagging |
| Data Output | USB Type-C interface for direct PC transfer |
| IP Rating | IP68-rated electrodes |
| Operating Environment | 0–50 °C, ≤85% RH (non-condensing) |
| Electrode Cable Length | Standard 3–5 m (customizable) |
| Compliance | Designed per ISO 7027 (turbidity), ISO 5814 (DO), ISO 7888 (EC/TDS), ASTM D1293 (pH), USP <643> (TOC proxy via COD), and GLP-aligned data integrity architecture |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HT-SS-I |
| Instrument Type | Portable |
| Measurement Principle | ISO 7027-compliant dual-beam infrared light scattering and absorption |
| Range | 0.1–50,000 mg/L (customizable high-range options available) |
| Accuracy | ±5% of reading (dependent on sample homogeneity) |
| Resolution | 0.01–1 mg/L (scale-dependent) |
| Sensor Material | SUS316L stainless steel |
| Host Housing | ABS+PC polymer blend |
| Sensor IP Rating | IP68 |
| Host IP Rating | IP67 |
| Operating Temperature | 0–50 °C (non-freezing) |
| Storage Temperature | −15 to 60 °C |
| Sensor Dimensions | Ø60 mm × 254 mm, 1.65 kg |
| Host Dimensions | 203 × 100 × 43 mm, 0.5 kg |
| Standard Cable Length | 3 m (extendable) |
| Display | 3.5-inch color LCD with adjustable backlight |
| Data Storage Capacity | >100,000 records |
| Power | Rechargeable Li-ion battery, USB-C charging (no battery removal required) |
| Interface | USB data export |
| Calibration Options | Standard solution calibration and field water sample calibration |
| Auto-sensor recognition | Yes |
| Sensor configuration & calibration via host | Yes |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | YN/SS-2Z |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm |
| Minimum Display Resolution | 0.01 ppm |
| Repeatability | ≤2% |
| Accuracy | ≤±5% FS |
| Power Adapter | AC 220 V, 50 Hz |
| Compliance | Designed for field-deployable water quality monitoring per standard turbidimetric principles |
| Brand | Lohand |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LH-P3SS |
| Instrument Type | Portable |
| Display | 3.5-inch color TFT LCD with dial-style UI |
| Battery | Rechargeable lithium-ion, up to 8 hours continuous operation under typical field conditions |
| Calibration | Optical intensity calibration supported |
| Calibration Curves | 5 built-in calibration curves for turbidity-to-SS correlation |
| Measurement Limit Indication | Visual upper-limit alert (red highlight) on dial interface |
| Data Output | Concentration directly displayed in mg/L (ppm) units |
| Brand | Lohand |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LH-SF10 |
| Instrument Type | Laboratory Benchtop Filtration System |
| Vacuum Pump Type | Oil-Free Electromagnetic Piston Pump |
| Max. Simultaneous Samples | 6 |
| Filtration Capacity per Cup | 300 mL |
| Filter Membrane Diameter Options | 47 mm or 50 mm |
| Operating Noise Level | < 50 dB(A) |
| Construction Material | 304 Stainless Steel |
| Chemical Resistance | Acid- and Alkali-Resistant Design |
| Lubrication | Fully Oil-Free Operation |
| Continuous Duty Rating | 24/7 Stable Operation |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | ET99700 |
| Stirring Positions | 4 |
| Speed Range | 10–150 rpm, continuously variable |
| Speed Accuracy | ±10 rpm |
| Operating Temperature | 10–45 °C |
| Power Supply | 220 V / 60 Hz |
| Dimensions | 230 × 245 × 325 mm |
| Weight | ~6.9 kg |
| Compliance | CE Marked |
| Standard Configuration | ET99700 unit, carrying case, user manual, warranty card (Chinese) |
| Note | 1500 mL low-temperature and high-temperature beakers (for ET99710) sold separately |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek1 |
| Type | Online Analyzer |
| Application | Real-time turbidity and total suspended solids (TSS) measurement in liquid process streams |
| Brand | TUNE VOLT |
|---|---|
| Model | TW-5258 |
| Origin | Beijing, China |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Range | 0–1000 mg/L |
| Minimum Resolution | 0.01 mg/L |
| Accuracy | ≤ ±2% F.S. |
| Repeatability | ≤ 3% |
| Optical Drift | < 0.002 A in 20 min |
| Dimensions (with printer) | 340 mm × 250 mm × 130 mm |
| Dimensions (without printer) | 266 mm × 200 mm × 130 mm |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 0.5 Hz |
| Weight | 4 kg |
| Brand | YST Environmental |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–5000 mg/L (extendable to 0–50000 mg/L) |
| Measurement Principle | Dual-beam infrared scattering and transmission hybrid optics |
| Output Signals | 4–20 mA analog output, RS485 digital interface (HJ 212 protocol compliant) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | −10 °C to +55 °C |
| Ingress Protection | IP68 |
| Installation Options | Submersible or flow-through configurations |
| Cleaning Mechanism | Integrated air-pulse auto-cleaning system |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–500 / 0–1000 / 0–5000 mg/L (field-selectable) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Output Signals | 4–20 mA analog, RS485 digital |
| Power Supply | AC 220 V ±10% @ 50/60 Hz or DC 24 V ±10% |
| Installation | Submersible |
| Probe IP Rating | IP68 |
| Enclosure IP Rating | IP65 |
| Compliance | Designed for continuous in-situ SS monitoring per ISO 7027 (turbidity correlation), ASTM D3977, and EPA Method 160.1 principles |
| Brand | YST (Dalian Yist Instrument Co., Ltd.) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Principle | Infrared Dual-Scatter Optical Detection |
| Range | 0–5000 mg/L (extendable to 0–20,000 mg/L) |
| Accuracy | ±2% FS (0–100 mg/L), ±5% FS (100–5000 mg/L) |
| Output | RS485 with Modbus RTU Protocol |
| Power Supply | DC 12–24 V, <50 mA avg. |
| Operating Temperature | −5 to +50 °C |
| Humidity | <85% RH (non-condensing) |
| Enclosure Rating | IP68 |
| Housing Material | 316 Stainless Steel + Polyoxymethylene (POM) |
| Brand | YST (Dalian Yist Environmental Technology Co., Ltd.) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Principle | Infrared Scattering (880 nm) |
| Range | 0–50,000 mg/L (multi-range configurable) |
| Power Supply | DC 12–24 V, <50 mA avg. |
| Output Signals | 4–20 mA analog, RS485 digital (Modbus RTU) |
| Sensor IP Rating | IP68 |
| Host IP Rating | IP65 |
| Sensor Operating Temp. | −10 to 60 °C |
| Host Operating Temp. | 0 to 50 °C |
| Installation Options | Top-mount, side-mount, submersible |
| Sensor Material | 316 stainless steel |
| Housing Material | POM engineering plastic |
| Brand | YST (Dalian Yist Environmental Technology) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–20,000 mg/L |
| Accuracy | ≤ ±2% FS |
| Output Signal | 4–20 mA DC |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Temperature | −10 °C to +55 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Ingress Protection | IP65 |
| Installation Options | Immersion or Flow-Through |
| Brand | Dalian YST |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–50 g/L (activated sludge), 0–400 g/L (silica) |
| Units | mg/L / ppm selectable |
| Accuracy | ±1–2% FS |
| Repeatability | ±1–2% |
| Operating Temp. | 0–50 °C |
| Max. Pressure | ≤10 bar |
| Flow Rate | 0.3–3 m/s |
| Output | 4–20 mA isolated |
| Communication | Modbus RTU/ASCII |
| Enclosure Rating | Transmitter IP65, Sensor IP68 |
| Power Supply | AC 220 V or DC 24 V |
| Weight | 6 kg |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–5000 mg/L SS, 0–80.0 °C |
| Accuracy | ±1.5% FS (SS), ±0.3 °C (Temp) |
| Resolution | 1 mg/L (SS), 0.1 °C (Temp) |
| Output | 4–20 mA & RS485 MODBUS RTU |
| Power Supply | 85–265 VAC ±10%, 50 ±1 Hz, ≤3 W |
| IP Rating | IP65 |
| Installation | Panel-mount / Wall-mount / In-line pipe mount |
| Operating Environment | −10 to +60 °C, ≤90% RH, non-corrosive, no strong magnetic field |
| Compliance | HJ 212–2017 (China Emission Monitoring Data Transmission Standard) |
| Brand | YST Instrument (Dalian) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Principle | Transmittance-Scattering Hybrid Optical Method |
| Range | 0–5000 mg/L |
| Accuracy | ≤±2% FS |
| Resolution | 1 mg/L |
| Response Time (T90) | ≤10 s |
| Operating Temp. (Sensor) | −10–80 °C |
| Operating Temp. (Transmitter) | 0–50 °C |
| Humidity | ≤90% RH (non-condensing) |
| pH Compatibility | 2–12 |
| Output Signals | Isolated 4–20 mA analog + RS485 digital (Modbus RTU) |
| Power Supply | AC 220 V ±10% 50/60 Hz or DC 24 V ±10% |
| Enclosure Rating | Sensor IP68, Transmitter IP65 |
| Cleaning | Integrated Automatic Wiper System |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST308B-MS880T |
| Measurement Range | 0–2000 NTU / 0–500 mg/L (switchable) |
| Accuracy | ±1.5% FS |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz or DC 24 V ±10% (optional) |
| Output Signal | 4–20 mA isolated (load < 750 Ω) |
| Ingress Protection | IP65 |
| Operating Temperature | 0–60 °C |
| Data Logging | 1 month @ 5-min intervals (non-volatile memory, 10-year data retention after power loss) |
| Installation | Flow-through sensor |
| Compliance | HJ 212–2017 protocol support for environmental monitoring platform integration |