- All
- Favorite
- Popular
- Most rated
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC330 |
| Type | Thermal Mass Flow Controller |
| Flow Range Options | 0–2 / 10 / 20 / 50 / 100 / 300 / 500 sccm |
| Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Control Range | 1–100% FS (1:100) |
| Measurement Range | 0.5–100% FS (1:200) |
| Response Time | <3 s |
| Warm-up Time | 5 min (T95), 30 min optimal |
| Max Operating Pressure | 3 MPa (30 bar) |
| ΔP Range | 0–1 MPa |
| Ambient & Gas Temp | −20 to +65 °C |
| Humidity | 0–98% RH (non-condensing) |
| Wetted Materials | FKM elastomer, 304/316 stainless steel |
| Electrical Interface | Analog 0–5 V / 0–10 V / 4–20 mA, RS485 Modbus RTU |
| Enclosure Rating | IP40 |
| Mounting | Horizontal only |
| Weight | 0.96 kg |
| Brand | AITOLY |
|---|---|
| Model | MFC300 |
| Type | Thermal Mass Flow Meter |
| Gas Compatibility | Argon (calibrated) |
| Response Time | 5 ms (measurement), 300 ms (control) |
| Flow Range | Standard range 0–100 sccm to 0–20 SLM (configurable per calibration) |
| Accuracy | ±1% FS (typical, argon-calibrated) |
| Repeatability | ±0.2% FS |
| Pressure Drop | <1 kPa at full scale |
| Operating Temperature | 0–50 °C |
| Compensated | Integrated temperature & pressure compensation |
| Output Signals | Analog (0–5 V / 4–20 mA), RS-485 (Modbus RTU), optional USB/DeviceNet |
| Communication Protocols | Modbus RTU, optional custom protocol support |
| Certifications | ISO 9001 certified manufacturing |
| Compliance | Designed for industrial process control environments |
| Brand | AITOLY |
|---|---|
| Model | MFC330 |
| Type | Thermal Mass Flow Controller |
| Sensor Principle | Capillary Tube + Bypass Shunt |
| Flow Range Options | 0–2, 10, 20, 50, 100, 300, 500 sccm |
| Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Control Range | 1–100% FS (1:100) |
| Measurement Range | 0.5–100% FS (1:200) |
| Response Time | <3 s |
| Warm-up Time | 5 min (T95), 30 min for optimal stability |
| Operating Pressure Drop | 0–1 MPa |
| Valve Type | Normally Closed Proportional Solenoid Valve |
| Optional | All-Metal Proportional Valve, Integrated Digital Display |
| Gas Compatibility | Clean, dry gases (≥98% purity) |
| Power Supply | Standard 24 VDC input |
| Output Signal | 0–5 VDC / 0–10 VDC / 4–20 mA analog |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC300 |
| Type | Thermal Mass Flow Controller |
| Sensor Technology | MEMS-based |
| Response Time (Measurement) | 5 ms |
| Response Time (Control) | 300 ms |
| Flow Range Ratio | Up to 100:1 |
| Pressure Drop | Low |
| Installation | Flexible (Inline/Panel Mount) |
| Power Supply | 24 VDC |
| Output Signal | 0–5 V / 0–10 V / 4–20 mA |
| Communication Interface | RS-485 (Modbus RTU) |
| Temperature & Pressure Compensation | Integrated |
| Warm-up Time | None Required |
| Brand | Atotech (AITOLY) |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC300_RS485 |
| Type | Thermal Mass Flow Controller |
| Power Supply | 15–40 VDC |
| Communication Interfaces | RS232 / RS422 / RS485 / CAN (galvanically isolated) |
| Accuracy | ±0.5% FS |
| Linearity | ±1% FS |
| Repeatability | ±0.5% FS |
| Response Time | <1 s |
| Full-Scale Flow Ranges | 0–5, 10, 50, 100, 200, 300, 500 sccm |
| Display Resolution | 0.1 sccm |
| Operating Pressure Differential | 0–1 MPa |
| Burst Pressure | 1.1 MPa |
| Ambient Temperature Range | 0–65 °C |
| Gas Compatibility | Air, He, Ar, N₂, CO₂ |
| Electrical Interface | DB9 connector |
| Gas Port Options | M8×1 thread, 4 mm push-to-connect, 6 mm push-to-connect |
| Tubing ID | 3–3.2 mm, 4 mm, 6 mm |
| Zero Drift | Extremely low |
| Moving Parts | None |
| Brand | Atotech |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC330 |
| Flow Principle | Thermal Mass Flow Measurement |
| Flow Ranges | 0–5/10/20/50/100/200/300/500 SCCM |
| Accuracy | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Flow Rangeability | 2–100% FS |
| Operating Temperature | −20 to +65 °C |
| Humidity | 0–98% RH (non-condensing) |
| Max Working Pressure | 3 MPa |
| Response Time | <1 s |
| Supply Voltage | 15–40 VDC |
| Power Consumption | <5 W |
| Communication Interfaces | RS232, RS485, CAN, 0–5 VDC analog output, 4–20 mA analog output |
| Gas Path Materials | SUS304 / SUS316L |
| Seals | FKM (Viton®) |
| Connection Types | Push-to-connect, Quick-fit, Swagelok®-style ferrule, VCR |
| Electrical Interface | DB9 male |
| Display & Control | Integrated LCD with membrane keypad |
| Built-in Sensors | Temperature and pressure compensation sensors |
| Gas Compatibility | Multi-gas (N₂, O₂, Ar, He, CO₂, H₂, Air, N₂O, CH₄, etc., with gas-specific calibration) |
| Brand | Atotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Thermal Mass Flow Controller |
| Model | MFC330 |
| Flow Range Options | 0–2 / 10 / 20 / 50 / 100 / 300 / 500 sccm |
| Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Control Range | 1–100% FS (1:100) |
| Measurement Range | 0.5–100% FS (1:200) |
| Response Time | <3 s |
| Warm-up Time | 5 min (T95), 30 min recommended for optimal stability |
| Valve Type | Normally Closed |
| Gas Compatibility | Clean, dry gases |
| Brand | Atotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Thermal Mass Flow Controller |
| Model | Atotech MFC330 Micro-Flow Gas Mass Flow Controller |
| Flow Range Options | 0–2, 10, 20, 50, 100, 300, 500 sccm |
| Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Control Range | 1–100% FS (1:100) |
| Measurement Range | 0.5–100% FS (1:200) |
| Response Time | <3 s |
| Warm-up Time | 5 min (T95), 30 min optimal |
| Valve Type | Normally Closed |
| Brand | Atotech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MFC330 |
| Product Category | Thermal Mass Flow Controller |
| Full Scale Ranges (N₂ equivalent) | 0–2, 10, 20, 50, 100, 300, 500 sccm |
| Measurement Range | 0.5% FS (1:200) |
| Control Range | 1–100% FS (1:100) |
| Accuracy (Standard) | ±1% FS |
| Accuracy (High Performance) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Settling Time (Control Mode) | <3 s |
| Warm-up Time (T95) | 5 min |
| Optimal Stability | 30 min |
| Valve Function | Normally Closed |
| Leak Integrity | ≤1×10⁻⁸ Pa·m³/s (He) |
| Max Operating Pressure | 3 MPa (30 bar) |
| Operating Differential Pressure | 0–1 MPa |
| Operating Temperature Range | −20 to +65 °C (ambient & gas) |
| Relative Humidity | 0–98% RH (non-condensing) |
| Process Connections | Push-in, Push-on, Compression, VCR (optional) |
| Wetted Materials | FKM elastomers, 304/316 stainless steel |
| Housing IP Rating | IP40 |
| Mounting Orientation | Horizontal only (factory calibrated) |
| Mounting Holes | M4 × 5 mm |
| Weight | 0.96 kg |
| Electrical Interface | DB9 male |
| Analog I/O | 0–5 VDC, 4–20 mA (configurable) |
| Input Impedance | >10 MΩ |
| Output Impedance | <1 kΩ |
| Analog Data Update Rate | 200 Hz |
| Digital Interface | Modbus RTU (RS232/RS485), CAN |
| Baud Rates | 9600–115200 bps (user-selectable) |
| Power Supply | 15–40 VDC, <200 mA |
| Display Update Rate | 50 Hz |
| Analog Signal Accuracy | ±0.05% FS |
| STP Reference | 20 °C, 1 atm |
| Gas Selection | Software-configurable for >98 gas types |
| Software | Aitoly Stepwise Flow Control Suite |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ESMFM-650 |
| Product Category | Thermal Mass Flowmeter-Based Calibration Standard |
| Key Features | Multi-channel soap film calibration |
| Flow range | 1–10,000 mL/min (standard conditions) |
| Accuracy | ±0.5% of reading (typical, per ISO 4064 Class B) |
| Operating temperature | 15–35 °C |
| Ambient pressure range | 80–106 kPa |
| Display | 7-inch capacitive touchscreen |
| Compliance | Designed to support ISO/IEC 17025-compliant calibration workflows |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Type | Thermal Mass Flow Controller |
| Technology | Constant Temperature Anemometry (CTA) |
| Communication Protocols | RS-232, RS-485 (Modbus RTU), 0–5 V / 0–10 V analog output, optional CAN bus |
| Gas Compatibility | Air, N₂, O₂, CO₂, Ar, He, H₂, CH₄, and custom gas calibrations (up to 10 pre-loaded gases) |
| Accuracy | ±(0.8% of reading + 0.2% of full scale) |
| Repeatability | ≤ ±0.2% FS |
| Response Time | < 100 ms (t₉₀) |
| Operating Pressure Range | 0.1–1.0 MPa (absolute) |
| Ambient Temperature | 5–50 °C |
| Enclosure Rating | IP65 |
| Certifications | ISO 9001 certified manufacturing |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC330 |
| Type | Thermal Mass Flow Controller |
| Flow Range Options | 0–2, 10, 20, 50, 100, 300, 500 sccm |
| Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Control Range | 1–100% FS (1:100) |
| Measurement Range | 0.5–100% FS (1:200) |
| Response Time | <3 s |
| Warm-up Time | 5 min (T95), 30 min recommended for optimal stability |
| Operating Pressure Drop | 0–1 MPa |
| Valve Type | Normally Closed Proportional Valve |
| Sensor Principle | Capillary-tube-based thermal mass flow sensing with bypass分流 architecture |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC350 |
| Flow Sensing Principle | Capillary Thermal Mass Flow Measurement |
| Flow Control Type | Integrated Mass Flow Controller (MFC) |
| Sensor Technology | Patented Capillary Tube-Based Thermal Sensor |
| Valve Type | High-Precision Proportional Control Valve |
| Certification | ISO 9001 Certified Manufacturing |
| Compliance | Designed for GLP/GMP-adjacent laboratory and industrial process environments |
| Output Signal | 0–5 VDC / 4–20 mA (configurable) |
| Power Supply | 24 VDC ±10% |
| Accuracy | ±1% FS (typical, per manufacturer specification) |
| Repeatability | ±0.2% FS |
| Response Time | <1 sec (t₉₀) |
| Operating Temperature Range | 0–50 °C |
| Gas Compatibility | Air, N₂, O₂, CO₂, Ar, He, H₂, and other non-corrosive gases (custom calibration available) |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Model | AITOLY MFC300 |
| Type | Thermal Mass Flow Controller |
| Power Supply | 15–40 VDC |
| Output Options | Analog (0–5 V / 0–10 V / 4–20 mA) and Digital (RS232 / RS485 / CAN) |
| Flow Range | 0.2–100% FS (Turndown Ratio 1:500) |
| Accuracy | ±0.5% FS |
| Repeatability | ±0.5% FS |
| Linearity | ±0.2% FS |
| Resolution | 0.1 sccm (0–1000 sccm) |
| Sensor Response Time | 5 ms |
| Control Response Time | 300 ms |
| Warm-up Time | ≤1 s |
| Valve Type | Normally Closed |
| Compatible Gases | Air, N₂, O₂, Ar, CH₄, CO₂ |
| Gas Requirements | Clean, dry, non-corrosive |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC300 |
| Type | Thermal Mass Flowmeter |
| Flow Range | 0.2–100% FS (1:500) |
| Accuracy | ±0.5% FS |
| Repeatability | ±0.5% FS |
| Linearity | ±0.2% FS |
| Resolution | 0.1 sccm (0–1000 sccm), 1 sccm (1–5 slpm) |
| Sensor Response Time | 5 ms |
| Control Response Time | 300 ms |
| Warm-up Time | ≤1 s |
| Valve Type | Normally Closed |
| Compatible Gases | Air, N₂, O₂, Ar, CH₄, CO₂ |
| Gas Requirements | Clean, dry, non-corrosive |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AITOLY MFM330 |
| Price | USD 650 (FOB) |
| Type | Thermal Mass Flow Meter |
| Media | Clean, dry gases |
| Gas Compatibility | ≥98% purity (N₂, O₂, Ar, He, CO₂, air, and common gas mixtures) |
| Flow Ranges | 10–500 sccm / 0–500 slpm (selectable) |
| Measurement Range | 0.5–100% of Full Scale |
| Accuracy | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Resolution | 0.001 sccm (<10 L/min), 1 sccm (10–50 L/min) |
| Sensor Response Time | <1 s |
| Warm-up Time | 5 min to T95, 30 min for optimal stability |
| Pressure Drop | <1 kPa at max flow |
| Operating Temperature | 0–50 °C |
| Output Signals | 0–5 VDC, 0–10 VDC, 4–20 mA (configurable) |
| Brand | AITOLY |
|---|---|
| Model | MFC330 |
| Type | Thermal Mass Flow Controller |
| Accuracy | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Flow Range | 2–100% FS |
| Operating Temperature | −20 to +65 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Max Working Pressure | 3 MPa |
| Response Time | <1 s |
| Power Supply | 15–40 VDC |
| Power Consumption | <5 W |
| Communication Interfaces | RS232, RS485, CAN, 0–5 VDC, 4–20 mA |
| Wetted Materials | SUS304 / SUS316L |
| Seals | FKM (Viton®) |
| Connection Types | Push-to-Connect, Compression, VCR, Quick-Release |
| Display | Integrated LCD with Keypad |
| Built-in Sensors | Temperature & Pressure Compensation |
| Gas Compatibility | Multi-gas (N₂, O₂, Ar, He, CO₂, H₂, Air, etc.) |
| Compliance | Designed for industrial process control environments requiring stable thermal mass flow measurement and closed-loop regulation |
| Brand | Aitoly |
|---|---|
| Model | MFC350 |
| Flow Range | 0–10 sccm |
| Measurement Principle | Thermal Mass Flow (Capillary-Based) |
| Accuracy | ±0.5% FS |
| Control Range | 1–100% FS (1:100) |
| Full-Scale Repeatability | ±0.2% FS |
| Response Time (t₉₀) | <1 s |
| Operating Pressure Drop | 0–1 MPa |
| Maximum Burst Pressure | 3 MPa |
| Valve Type | Normally Closed (NC) Solenoid Valve |
| Warm-up Time (T₉₅) | 5 min |
| Gas Compatibility | >90 Pre-Configured Gases (N₂, O₂, Ar, He, CO₂, H₂, CH₄, NH₃, etc.) |
| Standard Conditions | 20 °C, 101.325 kPa (user-adjustable) |
| Output Signals | 0–5 Vdc, 4–20 mA, RS232, RS485, CAN, EtherCAT |
| Display | Optional Integrated OLED or External PC/HMI Interface |
| Enclosure Rating | IP65 (industrial-grade housing) |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MFM610 |
| Pricing | Upon Request |
| Flow Technology | Thermal Mass |
| Flow Ranges | 0–5 / 10 / 50 / 100 / 200 / 300 / 500 / 1000 sccm (mL/min) |
| Accuracy | ±0.5% FS |
| Repeatability | ±0.5% FS |
| Max Operating Pressure | 1 MPa |
| Power Supply | 12–40 VDC (dual-input compatible) |
| Electrical Interface | DB9 connector |
| Gas Fitting Options | 3–3.2 mm & 6 mm compression fittings |
| Measurable Gases | Air, He, Ar, N₂, O₂, H₂, NO, CO, CH₄, NH₃, N₂O, NO₂, CO₂ |
| Output Interfaces | CAN, RS485, RS232 |
| Alarm Output | 1 programmable flow threshold relay output |
| Display | Integrated LCD |
| Software Support | Free PC-based configuration and data logging software |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Type | Thermal Mass Flow Controller |
| Flow Range Options | 0–2 / 10 / 20 / 50 / 100 / 300 / 500 sccm |
| Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Control Range | 1–100% FS (1:100) |
| Measurement Range | 0.5–100% FS (1:200) |
| Response Time | <3 s |
| Warm-up Time | 5 min (T95), 30 min for optimal stability |
| Valve Type | Normally Closed |
| Pressure Drop | Low |
| Operating Differential Pressure | 0–1 MPa |
| Gas Compatibility | Clean, dry gases |
| Sensor Principle | Capillary-tube-based thermal mass flow sensing with bypass shunt architecture |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Model | MFC300_RS232 |
| Flow Principle | Thermal Mass Flow Measurement |
| Power Supply | 15–40 VDC |
| Accuracy | ±0.5 % FS |
| Linearity | ±1 % FS |
| Repeatability | ±0.5 % FS |
| Response Time | <1 s |
| Full-Scale Range Options | 0–5 to 0–5 L/min (sccm/LPM) |
| Operating Pressure Differential | 0–1 MPa |
| Max Burst Pressure | 1.1 MPa |
| Ambient Temperature | 0–65 °C |
| Gas Compatibility | Air, He, Ar, N₂, O₂, H₂, NO, CO, CH₄, NH₃, N₂O, NO₂, CO₂ |
| Electrical Interface | DB9 connector |
| Output Signals | Analog (0–5 V / 0–10 V / 4–20 mA), RS232, RS485, RS422, CAN (galvanically isolated) |
| Gas Port Options | M8×1, 4 mm push-to-connect, 6 mm push-to-connect |
| Tubing ID | 3–3.2 mm, 4 mm, 6 mm |
| Display Resolution | 0.1 sccm (for low-range models) |
| Zero Drift | Extremely low (typ. <0.02 % FS/°C) |
| Moving Parts | None |
| Brand | AITOLY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AITOLY MFC330 Thermal Mass Flow Controller |
| Price | USD 650 (excl. tax & shipping) |
| Flow Measurement Principle | Thermal Mass Flow (Constant Temperature Anemometry) |
| Flow Control Architecture | Closed-loop PID with Integrated Proportional Valve |
| Enclosure Material | Anodized Aluminum Housing |
| Electrical Interface | Analog (0–5 V / 4–20 mA) + RS485 Modbus RTU |
| Media Compatibility | Clean, dry, non-corrosive gases |
| Gas Selection | Pre-calibrated for 98+ common industrial and process gases (N₂, O₂, Ar, He, CO₂, Air, H₂, CH₄, etc.) |
| Full-Scale Ranges | 0–2, 10, 20, 50, 100, 300, 500 sccm |
| Measurement Accuracy | ±1% FS |
| Repeatability | ±0.2% FS |
| Linearity | ±0.2% FS |
| Flow Control Range | 1–100% FS (1:100 turndown) |
| Minimum Measurable Flow | 0.5% FS (1:200 resolution) |
| Response Time (Control) | <3 s (10–90% step) |
| Warm-up Time | 5 min to T95, 30 min for optimal stability |
| Operating Pressure Range | 0–1 MPa (gauge) |
| Pressure Drop | <1 kPa at full scale (typ.) |
| Valve Type | Normally Closed Stainless Steel Proportional Solenoid Valve |
| Optional Accessories | Integrated OLED Display Module, Full-Metal Flow Body (316L SS), NIST-Traceable Calibration Certificate, Gas-Specific Firmware Load |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Type | Thermal Mass Flow Controller |
| Measurement Principle | Constant-Temperature Anemometry (CTA) |
| Accuracy | ±0.2% FS |
| Repeatability | ±0.05% FS |
| Linearity | ±0.1% FS |
| Response Time (90%) | ≤100 ms |
| Control Range | 1–100% FS (100:1 turndown) |
| Full-Scale Flow Ranges | 0–1, 5, 10, 20, 50, 100, 300, 500 sccm |
| Gas Compatibility | >130 pre-calibrated gases (including N₂, O₂, Ar, He, CO₂, CH₄, H₂, NH₃, SF₆, and custom blends) |
| Operating Pressure Drop | 0–1 MPa |
| Valve Type | Normally Closed Solenoid |
| Seal Options | FKM (leak rate ≤1×10⁻¹⁰ Pa·m³/s He) or All-Metal (leak rate ≤1×10⁻¹¹ Pa·m³/s He) |
| Resolution | 0.001 sccm |
| Warm-up Time | 0 s |
| Communication Interfaces | 0–5 V / 0–10 V / 4–20 mA analog |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | Aitoly |
|---|---|
| Origin | Jiangsu, China |
| Model | ESMFM-650 Soap Film Gas Flow Standard Calibrator |
| Flow Measurement Principle | Soap film displacement timing (volumetric flow standard) |
| Measurement Channels | 3 independent volumetric channels |
| MFC Integration | 4-channel integrated mass flow controllers (MFCs) |
| Flow Range (Volumetric) | Channel 1: 0.05–50 mL/min |
| Channel 2 | 20–1000 mL/min |
| Channel 3 | 500–5000 mL/min |
| Accuracy Class | ±0.5% of reading |
| MFC Ranges & Resolution | MFC1: 0–50 sccm (±0.01 sccm) |
| MFC2 | 0–300 sccm (±0.1 sccm) |
| MFC3 | 0–1000 sccm (±0.1 sccm) |
| MFC4 | 0–6000 sccm (±1 sccm) |
| Environmental Operating Conditions | 5–45 °C, ≤85% RH |
| Power Supply | 220 VAC |
| Compliance | Designed for ISO/IEC 17025-compliant calibration workflows |