BrandAqualab
OriginUSA
ModelPre
Measurement PrincipleChilled-Mirror Dew Point
Operating Temperature Range4–50 °C
Repeatability±0.01 a<sub>w</sub>
ApplicationLaboratory-Grade Dew Point Water Activity Analyzer
ComplianceAOAC, FDA, ISO 21807, USP <1112>, ASTM F1980
Sample Temperature ControlPrecisely maintained at 25 °C (±0.1 °C)
Typical Measurement Time< 5 minutes
CalibrationFactory-calibrated with NIST-traceable standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAQUALAB
OriginUSA
ModelAquaLab TDL 2
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS) at H₂O-specific isotopic absorption line (1368.59 nm)
Range0.0000–1.0000 aw
Resolution0.0001 aw
Accuracy±0.005 aw @ 25 °C
Repeatability±0.001 aw
Temperature Control Range15–50 °C
Temp. Accuracy±0.1 °C
Measurement Time≤5 min (standard), 1 min (optional rapid mode)
Operating Environment0–90% RH non-condensing, 4–50 °C ambient
InterfaceRS-232 & USB
ComplianceUSP <922>, AOAC Official Method 2014.01, ISO 21807:2022, ASTM F1980-22
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAqualab
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelROS 1
PricingAvailable Upon Request
Measurement PrincipleStandard Gravimetric Loss-on-Drying (LOD) with Real-Time Mass Monitoring
Heating MethodResistive Coil Conduction (Not Halogen or Microwave)
Sample Capacity9 Independent Positions
Temperature Range50–150 °C (1 °C Increments)
Balance Readability0.0001 g
Max Load per Pan50 g
Sample Weight Range1–15 g
Moisture Range0.1–100 % w/w
Accuracy±0.15 %
Repeatability (4 g)±0.05 %
Repeatability (10 g)±0.01 %
ComplianceAOAC 937.02, ASTM D4442, ISO 4463, USP <921>, FDA 21 CFR Part 11 Ready (with optional software audit trail)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAqualab
OriginUSA
Model4TE
Measurement PrincipleChilled-Mirror Dew Point
Operating Temperature Range4–50 °C
Accuracy±0.003 aw
Repeatability±0.001 aw
ApplicationLaboratory-Grade Water Activity Analysis
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAero Laser
OriginItaly
ModelAL2021SC
Detection PrincipleEnzyme-catalyzed fluorometric assay (horseradish peroxidase or catalase-based)
Linear Range0.1–2000 ppb (gas phase), 150 ng/L–5 mg/L (liquid phase)
LOD<100 ppt (gas), <150 ng/L (liquid), <2×10⁻⁹ mol (liquid)
Response Time (10–90%)90 s
System Delay~300 s
Noise Level≤2% FS
Sample Temp. Range>0 °C to +120 °C
CalibrationAuto-zero + semi-automated liquid standard calibration (optional)
InterfaceTouchscreen GUI + remote operation via Android tablet or PC
ConnectivityLAN, RS232
Data LoggingInternal memory + USB export
SoftwareSOL-based graphical data recording & visualization
Dimensions45 cm × 15 cm × 56 cm (19″ rack-mountable)
Weight15 kg
Power110/220 VAC, 110 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXFORMMA
OriginHong Kong
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (PRC-manufactured)
ModelARCUS 5
Instrument TypeHPLC/UHPLC Autosampler
Sample CapacityUp to 108 × 2 mL vials (configurable with 10 mL, 4 mL, or 96-well PCR plates)
Max Operating Pressure40 MPa
Injection Volume Range0.1–1000 µL (standard configuration: 0.1–120 µL)
Syringe Volume200 µL (resolution: 0.1 µL)
Sampling ModesFull-loop, Partial-loop, and Needle-into-loop (NIL) / Zero-dead-volume sampling
Vial Height Limit≤52 mm (including septum and cap)
Pump Lifetime≥1,000,000 injections
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelCN802
Detection PrincipleHigh-Temperature Combustion (Dumas Method) coupled with NDIR CO₂ detection and TCD N₂ detection
Sample ThroughputUp to 30 samples unattended
Sample FormSolid and liquid (up to 1 g)
Carrier GasesHelium or Argon (switchable without hardware modification)
ComplianceAOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA
Detection TechnologiesNDIR for CO₂, LoGas™ TCD for N₂
Moisture RemovalDriStep™ integrated desiccant system
Automation30-position autosampler (expandable to 90 positions with additional trays)
Software PlatformCNSoft™ + Ermes Cloud Connectivity
Regulatory SupportAudit trail, user management, electronic signatures (21 CFR Part 11 ready)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDreamLab
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDL-BE150H
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Supplier TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelSPS Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDreamLab (Junlebo)
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelDL-RC60S / DL-RC120S
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDreamLab
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelsDL-BE80V / DL-BE80VT / DL-BE120V / DL-BE120VT
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpinlock
OriginArgentina
ModelSLK-200
Field StrengthLow-field (typically 0.05–0.1 T, ~2–4 MHz ¹H Larmor frequency)
Sample TypeSolid-Liquid Dual Compatibility
Measurement TimeFat/Water: 4 s
Protein12 s
Fatty Acids20 s
AccuracyProtein >99%
AutomationOptional SLK-AS-10 Auto-sampler (2 × 50-position modules)
ComplianceDesigned for GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEXFORMMA
OriginHong Kong
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic (PRC-manufactured)
ModelEX1800 Ultra-High-Performance Liquid Chromatography (uHPLC) Analytical System
Instrument TypeUltra-High-Performance Liquid Chromatograph
Solvent Inlet ConfigurationDual 2-position/2-way switching valves enabling four independent solvent channels
Degasser Channel Volume380 µL
Pump TypeDual-plunger reciprocating parallel pump with integrated binary high-pressure mixer
Flow Rate Range0.001–10 mL/min
Maximum Operating Pressure42 MPa
Flow Accuracy≤ ±0.3%
Flow Precision (RSD)< 0.06% at 1 mL/min and 10 MPa
Pressure Pulsation≤ 0.1 MPa
Power Supply220 V AC / 110 V AC