Temperature and Humidity Measuring Instruments
Filter
Showing all 29 results
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Precision Resistance Thermometer |
| Model | MKT 50 |
| Temperature Range | −260 °C to +962 °C (−436 °F to +1764 °F) |
| Resistance Range | approx. 0 Ω to 440 Ω |
| Temperature Accuracy | ±0.0001 °C (±0.1 mK) for Pt100 |
| Resistance Accuracy | < 0.4 mΩ |
| Resolution | 40 μΩ (0.1 ppm full scale) |
| Operating Ambient Temperature | 0 °C to 35 °C (32 °F to 95 °F) |
| Display | Graphic LCD with LED backlight, 128×64 dots (≈65 mm × 35 mm) |
| Power Supply | 2 × AA batteries (1.2–1.5 V) or AC adapter: 100–240 VAC, 50/60 Hz, output 7.5 VDC, 5.34 A, max 40 W |
| Dimensions | 240 mm × 190 mm × 110 mm |
| Weight | 2 kg |
| Brand | AS ONE |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Manufacturer |
| Country of Origin | China (Domestic) |
| Model No. | 1-5812-01 |
| Temperature Range | -50 to +1300 °C |
| Resolution | 0.1 °C / 1 °C (switchable) |
| Display | 3.5-digit LCD with backlight |
| Accuracy | ±0.3% rdg + 1 °C (-50 to +1000 °C) |
| Sampling Rate | 2.5 readings/sec |
| Power Supply | 1 × 006P (9 V) battery (included) |
| Dimensions | 155 × 65.5 × 35 mm |
| Weight | 177 g |
| Thermocouple Type | K-type |
| Functions | Data Hold, Max Value Storage & Recall, Auto-Hold Trigger |
| Brand | AS ONE |
|---|---|
| Model | 2-3799-01 |
| Type | Digital Thermometer (Waterproof) |
| Display | LED |
| Dimensions | 70 × 40 × 175 mm |
| Compliance | RoHS 2 (EU Directive 2015/863) |
| Origin | China |
| Manufacturer | AS ONE (AS ONE Co., Ltd.) |
| Instrument Category | Temperature Measuring Instrument |
| Brand | ASP / Advanced Sensing Products |
|---|---|
| Origin | USA |
| Model | YKI Series |
| Temperature Range | −200 °C to 1100 °C |
| Resistance at 0 °C | 10 Ω, 100 Ω, 500 Ω, or 1000 Ω (customizable) |
| TCR (α) | 0.003850 Ω/Ω/°C |
| Accuracy Class | IEC 60751 DIN Class A (±0.06 °C at 0 °C) or Class B (±0.12 °C at 0 °C) |
| Stability | R₀ drift < 0.002 °C after 1000 h at 300 °C |
| Repeatability | R₀ deviation < 0.002 °C over 100 cycles (25–300 °C) |
| Thermal Hysteresis | < 0.001 °C (−196 °C to 300 °C) |
| Sheath Material | Stainless steel or Inconel® alloy |
| Standard Diameter | 3–6.35 mm |
| Standard Length | 305–457 mm (12–18 in) |
| Vibration Resistance | 20 g from 10–5000 Hz |
| Brand | ASP/Advanced Sensing Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | YKS500 Series |
| Instrument Category | Standard Platinum Resistance Thermometer (SPRT) |
| Temperature Range | −200 °C to +500 °C |
| Nominal Resistance | 25.5 Ω or 100 Ω (customizable) |
| Temperature Coefficient | α = 0.003850 Ω/Ω/°C or 0.003925 Ω/Ω/°C (IEC 60751 / ASTM E1137 compliant) |
| Stability (25–500 °C, 100 thermal cycles) | R₀ drift < 0.008 °C |
| Repeatability (25–500 °C, 100 cycles) | R₀ deviation < 0.008 °C |
| Vibration Resistance | 20 G, 10–2000 Hz |
| Probe Diameter | 4.78 mm (0.188″) or 6.35 mm (0.25″) |
| Probe Length | 305–457 mm (12–18″), customizable |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KSD-1000 |
| Instrument Type | Relative Humidity (RH) Sensor |
| Measurement Range | 0–100% RH |
| Accuracy | ±1.5% RH |
| Resolution | 1% RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Power Supply | 220 VAC, 50 Hz |
| Sensing Principle | Polymer Thin-Film Capacitive |
| Output Signal | 4–20 mA DC |
| Enclosure Rating | IP65 (Dust-Resistant & Corrosion-Resistant) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-230 |
| Temperature Range | 0–300 °C |
| Output | Analog (4–20 mA or 0–10 V selectable) |
| Alarm Outputs | Dual independent relay outputs |
| Mounting | Benchtop / Fixed-installation compatible |
| Compliance | CE marked, RoHS compliant |
| Enclosure Rating | IP65 (front panel) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | TTI-22 |
| Temperature Range | −250 °C to 960 °C |
| Measurement Uncertainty | ≤1 mK (0.001 °C) |
| Resolution | 0.0001 °C |
| Operating Ambient Temperature | 10 °C to 30 °C |
| Power Supply | 1 × AC mains input (100–240 V, 50/60 Hz) |
| Dimensions (W×H×D) | 190 mm × 112 mm × 240 mm |
| Weight | 1.8 kg |
| Sensor Compatibility | Pt25.5, Pt100 (industrial & standard), 4-wire configuration |
| Calibration Storage Capacity | Up to 30 sensor-specific calibration tables |
| Interface | RS232 serial port, Ethernet (TCP/IP), embedded web server |
| Compliance | ITS-90 (for SPRTs), DIN EN 60751 (for industrial Pt100), GLP/GMP-ready data logging with timestamped audit trail |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A.B.C.D.E Temperature Indicating Strip |
| Pricing | Available Upon Request |
| Temperature Range | −30 °C to 260 °C |
| Accuracy | ±1 °C |
| Calibration Traceability | ISO/IEC 17025-accredited reference standards |
| Compliance | ISO 9001 certified manufacturing & quality control |
| Format | Adhesive-backed multi-point irreversible thermal indicator strip with 5 discrete temperature bands (A–E), each containing 8 calibrated temperature-sensitive elements |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| IP Rating | IP65 |
| Probe Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Folded Dimensions | 163 × 47 × 20 mm |
| Extended Dimensions | 265 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Power Supply | 2 × AAA batteries |
| Battery Life | 100 h (+25 °C, no backlight) |
| Display | Single-line LCD with backlight |
| Compliance | EN 13485, HACCP, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1063 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-30 to +99.9 °C), ±1.0 °C (full range) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| Power Source | CR2032 lithium coin cell |
| Dimensions (L×W×H) | 215 × 34 × 19 mm |
| Weight | 80 g |
| IP Rating | IP67 (with protective sleeve 0516 8265) |
| Measurement Rate | 2 readings per second |
| Compliance | ISO/IEC 17025 traceable calibration options available |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | −10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery (approx. 70 h lifetime) |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Sensor Type | Integrated capacitive humidity sensor + NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 0104 |
| Temperature Range | -50 to +250 °C |
| Accuracy | ±1.0 °C (-50 to -30.1 °C), ±0.5 °C (-30 to +99.9 °C), ±1% of reading (+100 to +250 °C) |
| Resolution | 0.1 °C |
| Response Time (t₉₉) | 10 s (in moving liquid) |
| IP Rating | IP65 |
| Dimensions (probe extended) | 265 × 47 × 20 mm |
| Dimensions (probe folded) | 163 × 47 × 20 mm |
| Weight | 165 g (incl. batteries) |
| Probe Shaft Diameter | 3 mm |
| Probe Tip Diameter | 2.3 mm |
| Probe Sheath Length | 102 mm |
| Operating Temperature | -20 to +60 °C |
| Storage Temperature | -30 to +70 °C |
| Display | Single-line LCD with backlight |
| Power | 2 × AAA batteries (100 h life at +25 °C, no backlight) |
| Compliance | EN 13485, HACCP principles, EU Directive 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 1052 |
| Temperature Range | -50 to +275 °C |
| Accuracy | ±0.5 °C (-20 to +100 °C), ±1.0 °C (-50 to -20.1 °C), ±1% of reading (+100.1 to +275 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | -20 to +50 °C |
| IP Rating | IP65 |
| Display | Backlit LCD (single-line) |
| Power Supply | LR44 button cell battery (80 h typical life) |
| Dimensions (with standard probe) | 148 × 38 × 195 mm |
| Weight (instrument only, standard probe) | 156 g |
| Response Time t₉₉ | 10 s (standard/long probe in liquid), 15 s (frozen goods probe in frozen meat ≈ 60 s) |
| Compliance | EN 13485, HACCP principles, FDA food safety guidelines |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model No. | 0563 1063 |
| Price Range | USD 0.15–750 (FOB) |
| Instrument Category | Insertion-Type Food Thermometer |
| Temperature Range | −50 °C to +275 °C |
| Accuracy | ±0.5 °C (within −20 °C to +50 °C) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 °C to +50 °C |
| Display | Integrated LCD (backlit) |
| Power Supply | 1 × CR2032 button cell (included) |
| Dimensions (L×W×H) | 215 mm × 34 mm × 19 mm |
| Weight | 80 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 6053 |
| Temperature Range | 0 to +50 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Resolution | 0.1 %RH |
| Operating Ambient Temperature | 0 to +50 °C |
| Display | Rotatable LCD screen |
| Power Supply | 3 × AAA batteries |
| Dimensions | 12 mm (thickness) |
| Weight | 75 g (including batteries, excluding packaging) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 6251 |
| Temperature Range | -10 to +60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0 to 100 %RH |
| RH Accuracy | ±2.5 %RH (5–95 %RH) |
| RH Resolution | 0.1 %RH |
| Operating Ambient Temperature | -20 to +50 °C |
| Display | Backlit LCD |
| Power Supply | 9 V battery |
| Dimensions | 182 × 64 × 40 mm |
| Weight | 195 g |
| Enclosure Material | ABS |
| Battery Life | ~70 h |
| Storage Temperature | -40 to +70 °C |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0646 0073 |
| Temperature Range | +116 to +138 °C |
| Accuracy | ±1.5 °C |
| Operating Ambient Temperature | +116 to +138 °C |
| Dimensions | 15 mm diameter |
| Weight | 1 g |
| Quantity per Pad | 10 units |
| Indication Points | +116, +122, +128, +132, +138 °C (customizable thresholds per variant) |
| Response Time | ≤3 seconds upon exceeding threshold |
| Irreversible Visual Indication | Yes |
| Compliance | CE-marked, RoHS-compliant, designed for industrial process monitoring and cold chain validation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp JKT |
| Price | Upon Request |
| Thermocouple Types | J, K, T |
| Temperature Range | –250 °C to 1372 °C (K-type), –250 °C to 400 °C (T-type), –2.00 °C to 1000 °C (J-type) |
| Resolution | 0.1 °C (–99.9 °C to 299.9 °C) |
| Accuracy | ±0.2% of reading + 0.5 °C (t > –99.9 °C) |
| Offset Adjustment | ±10 °C |
| Display | LCD |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions (unit) | 140 × 70 × 35 mm |
| Weight (unit) | 200 g |
| Input Connector | 2-pin ANSI mini thermocouple interface |
| Data Hold | Yes |
| Auto Power-Off | Yes |
| Low-Battery Indicator | Yes |
| Factory-Calibrated | Yes |
| Self-Diagnostic Functions | Yes |
| Key-Based Calibration | Yes |
| Power-Save Mode | Yes |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-A |
| Temperature Range | -10°C to 160°C |
| Accuracy | ±0.07°C (-10°C to 160°C), ±0.1°F (14°F to 320°F) |
| Resolution | 0.01°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25" LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Probe Length | 20 cm (8"), Probe Diameter: 6.35 mm (1/4"), Tip Diameter: 4.76 mm (3/16") |
| Enclosure | Anodized aluminum housing (3.5" × 12"), silicone-sealed |
| Weight | 93 g (3.3 oz) |
| Auto-off | After 20 minutes of inactivity or continuous operation |
| Units | Switchable °C / °F |
| Sensor Material | Stainless steel |
| Thermal Response Time (in water bath) | 14 seconds |
| Battery Life | ~400 hours at 21°C (70°F) |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-R |
| Temperature Range | -18°C to 150°C |
| Accuracy | ±0.04°C or ±0.07°F |
| Resolution | 0.001°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25-inch LCD |
| Power Supply | 3V CR2032 lithium coin cell |
| Probe Length | 20 cm (8 in), Diameter: 6.35 mm (1/4 in) |
| Weight | 124 g |
| Sensor Type | 200 Ω wound-wire Pt RTD |
| Immersion Depth | 11 cm (4 in) |
| Response Time | ≤3 min to ±0.1°C in water bath (0–50°C) |
| Auto-off | After 20 min idle or continuous operation |
| Units | Switchable °C/°F |
| Enclosure | Anodized aluminum housing (3.5" × 12"), silicone-sealed |
| Battery Life | 400 hours at 21°C (70°F) |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-W |
| Temperature Range | -10°C to 160°C |
| Accuracy | ±0.1°F |
| Resolution | 0.01°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25-inch LCD |
| Power | 3V CR2032 lithium coin cell battery |
| Probe Length | 20 cm (8 in), Probe Diameter: 6.35 mm (1/4 in), Tip Diameter: 4.76 mm (3/16 in) |
| Enclosure | Aluminum housing (3.5" × 12"), silicone-sealed |
| Weight | 180 g |
| Sensor Type | 100 Ω, Class A 1/3 DIN RTD |
| Immersion Depth | 11 cm (4 in) |
| Stabilization Time in Water Bath | 14 s |
| Battery Life | 400 h at 21°C (70°F) |
| Intrinsic Safety Rating | II 2 G EEx ib IIB T4 |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL2 |
| Temperature Range | -20 to 150°C |
| Accuracy | ±0.03°C (at ambient, NIST-traceable) |
| Resolution | 0.001°C |
| Display | LCD |
| Power Supply | Internal rechargeable battery (50 h typical life) |
| Operating Ambient Temperature | -20°C to +54°C |
| Enclosure | Powder-coated steel, IP65-rated |
| Dimensions | 184 × 133 × 57 mm (7.25" × 5.25" × 2.25") |
| Weight | 1000 g |
| Sensor Interface | Standard 5-pin DIN connector, compatible with 200 Ω 4-wire RTD probes |
| Compliance | NIST-traceable calibration certificate included |
| Brand | ThermoProbe |
|---|---|
| Origin | Germany |
| Model | TL3 |
| Temperature Range | -40 °C to 204 °C ±0.06 °C |
| Accuracy | ±0.06 °C |
| Resolution | 0.01 °C |
| Operating Ambient Temperature | -20 °C to 54 °C |
| Display | 0.5-inch LCD with low-battery and error indicators |
| Power | CR2032 3 V lithium coin cell |
| Probe Length | 200 mm or 300 mm |
| Probe Diameter | 6.35 mm (shaft), 4.76 mm (tip) |
| Weight | 150 g |
| Stabilization Time in Water Bath | 6.5 s |
| Battery Life | >100 h at 21 °C |
| Battery Operating Temp Range | -20 °C to 54 °C |
| Compliance | NIST-traceable 4-point calibration certificate included |
| Warranty | 1 year |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TP5C |
| Temperature Range | -40°C to +204°C |
| Accuracy | ±0.2°F (-40°F to 200°F), ±0.5°F (200°F to 400°F) |
| Resolution | 0.1°C |
| Operating Ambient Temperature | -20°C to +54°C (-4°F to 130°F) |
| Display | LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Dimensions | 9.5"L × 7.2"H × 1.76"W in (241 mm × 183 mm × 45 mm) |
| Weight | 124 g |
| Probe Material | 304 Stainless Steel |
| Safety Certification | UL Listed for Class I, Division 1, Groups B, C, D |
| Calibration | NIST-traceable 4-point calibration report |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TP7-C |
| Temperature Range | −10 °C to 188 °C (14 °F to 370 °F) |
| Accuracy | ±0.2 °F (32–200 °F), ±0.5 °F (200–300 °F) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 °C to 54 °C |
| Display | LCD |
| Power | 9 V alkaline battery (≈50 h life) |
| Dimensions | 34.3 × 18.4 × 11.4 cm |
| Weight | 1.4 kg (with 23 m cable) |
| Sensor | Pt100 platinum RTD in stainless steel sheath |
| Cable | FEP/PFA-insulated, aramid-reinforced, static-dissipative jacket |
| Enclosure Materials | Polypropylene blend, stainless steel, aluminum |
| Safety Certification | ATEX II 2 (1) EEx ib[ia] IIB T4 |
| Compliance | API RP 14C, IEC 60079-0/-11, UL 913 Class I, Div 1, Groups B, C, D |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TP9 |
| Temperature Range | -40°C to 204°C |
| Accuracy (Calibrated) | ±0.1°C (0–100°C), ±0.3°C (100–200°C), ±0.5°C (200–204°C) |
| Long-Term Drift | ≤0.05%/year |
| Resolution | 0.1°C |
| Operating Ambient Temperature | -20°C to +54°C |
| Display | LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Dimensions | 254 mm L × 108 mm H × 163 mm W |
| Weight | 2.0 kg |
| Enclosure Material | Anodized aluminum housing with stainless steel fasteners |
| Probe Construction | 304 stainless steel sensor tip, reinforced aramid fiber cable jacket (FEP or PFA), coaxial design |
| Certification | ATEX II 2 (1) EEx ib[ia] IIB T4 |
| Compliance | API RP 14C, NIST-traceable 4-point calibration certificate included |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 1-6124-81 |
| Temperature Range | 0–500 °C |
| Sensor Type | K-type Thermocouple |
| Display | Dual-digit LED (PV/SV) |
| Control Method | PID with Auto-Tuning & Over-Temperature Suppression |
| Output Terminal | 2P Socket + M4 Screw Terminal |
| Load Capacity | Up to 1000 W (Resistive Load) |
| Power Supply | AC 220 V |
| Dimensions | 135 × 110 × 82 mm |
| Included Accessory | K-type Thermocouple (φ3.2 mm × 200 mm, SUS304 Sheath, 1.9 m Cable) |
| Temperature Indication Accuracy | ±max(0.3% of SV, 3 °C) |
| Brand | Vaisala |
|---|---|
| Origin | Finland |
| Manufacturer | Vaisala Oyj |
| Product Type | Imported Industrial Dew Point Meter |
| Model | DM70 |
| Sensor Technology | Vaisala DRYCAP® Polymer Capacitive Sensor |
| Measurement Range | -60 to +60 °C dew point temperature (-76 to +140 °F) |
| Calibration | NIST-traceable certificate included |
| Data Logging | Internal memory with USB export via MI70 Link software |
| Environmental Protection | IP65-rated enclosure |
| Sampling Options | Multiple pressurized probe adapters available |
| Sensor Recovery | Automatic dry-out function for condensation recovery |