| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HFM-201 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUICK 1 |
| Pricing | Upon Request |
| Thermal Conductivity Range (VIP samples) | 0.001–0.015 W/(m·K) |
| Thermal Conductivity Range (Homogeneous samples) | 0.03–10.0 W/(m·K) |
| Repeatability (VIP) | ±5% or ±0.001 W/(m·K), whichever is greater |
| Repeatability (Homogeneous) | ±5% |
| Accuracy | Traceable to NIST-traceable reference standards |
| Operating Temperature | +5 °C to +40 °C |
| Measurement Time | ≤60 s per sample |
| Data Storage Capacity | 99 measurements |
| Power Supply | AC adapter, 100–240 V AC, 50/60 Hz |
| Dimensions | 250 × 200 × 90 mm |
| Weight | 4 kg |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TTech-GBT14402 |
| Standard Compliance | GB/T 14402-2007, GB 8624-2012, ISO 1716:2002 |
| Oxygen Bomb Capacity | (300 ± 50) mL |
| Maximum Oxygen Pressure | 3.5 MPa |
| Burst Pressure Rating | 21 MPa |
| Crucible Dimensions | Φ25 mm × (14–19) mm (stainless steel, 1 mm wall thickness) |
| Stirring Power | 3 W |
| Stirring Speed | 375 rpm (inner bucket) |
| Temperature Measurement Range | 4.5–50 °C |
| Temperature Resolution | 0.0001 °C (PT100 sensor) |
| Inner Bucket Volume | 2000 mL |
| Calorimeter Heat Capacity | ~10,000 J/K |
| Heat Capacity Repeatability Error | ≤0.2% |
| Timer Accuracy | ±0.5 s |
| Operating Ambient | 10–35 °C, RH ≤80% |
| Max Power Consumption | 0.5 kW |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | TESTech |
|---|---|
| Model | TTech-NFP92 |
| Origin | Jiangsu, China |
| Manufacturer | TESTech (OEM/ODM Producer) |
| Compliance | NF P 92-505, EU Directive 95/28/EC, ECE R118 Annex 7 |
| Radiation Aperture | 100 mm ± 5 mm |
| Radiant Flux at 30 mm Below Aperture | 3 W/cm² |
| Sample Holder Inner Diameter | 118 mm |
| Drip Collection Pan | 118 mm ID × 12 mm depth, lined with cotton wadding |
| Power Supply | 220 V AC, 50 Hz |
| Footprint | 425 mm × 300 mm |
| Max Height | 680 mm |
| Weight | 13 kg |
| Brand | WAZAU |
|---|---|
| Origin | Germany |
| Model | CHD DIN EN ISO 12127-1 |
| Heating Block Temperature Range | 20–500 °C |
| Contact Force | 49 N (5 kgf) |
| Heating Block Diameter | 25.2 mm |
| Sensor Probe Diameter | 25 mm, Thickness: 5 mm |
| Temperature Measurement Accuracy | ±0.1 °C |
| Time Resolution | ±0.1 s |
| Probe Approach Speed | 5 mm/s |
| Dimensions | 800 × 50 × 550 mm |
| Power Supply | 230 V, 50 Hz |