Thermal Dilatometer
Filter
Showing all 13 results
| Brand | ADVANCE RIKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super LIX-R |
| Price | Upon Request |
| Temperature Range (°C) | 0–50 |
| Heating/Cooling Rate (°C/min) | 0.01–1.5 |
| Temperature Accuracy (°C) | ±0.1 |
| Sample Diameter (mm) | Φ5 ±0.5 |
| Sample Length (mm) | 12–20 |
| Measurement Range (µm) | 20 |
| Resolution (nm) | <0.2 |
| CTE Detection Limit | 5 × 10⁻⁹ K⁻¹ |
| Thermal Stability | <±0.001 °C/min at 0.1 °C/min ramp |
| Atmosphere | Low-pressure He (100 Pa) |
| Sensor | PT-100 Platinum RTD (JIS C 1604-1997 Class A) |
| Laser | He-Ne, 632.8 nm, 5 mW (IEC 60825-1 Class 3B) |
| Brand | Aiyao Instruments |
|---|---|
| Model | TEA |
| Measurement Principle | Optical Interferometry |
| Sample Type | Transparent Bulk & Thin-Film Materials |
| Heating Method | IR Heater with PID + Fuzzy Logic Control |
| Temperature Control Mode | Programmable Ramp & Isothermal Hold |
| Vacuum Port | Yes |
| Cooling Interface | Water-Cooled Heat Exchanger & Optional Cryogenic/Gas Purge Connection |
| Origin | Hubei, China |
| Distributor Type | Authorized Domestic Distributor |
| Compliance | Designed for ISO 11359-2 and ASTM E228 Conformance Context |
| Brand | Analysis Tech |
|---|---|
| Origin | USA |
| Model | CTE-360 |
| Temperature Range | –25 °C to +100 °C |
| Compliance | ASTM D696, ASTM E228 |
| Sample Max Cross-Section | 12.5 mm (0.5 in) |
| Recommended Sample Length | 50 mm (2 in) |
| CTE Accuracy | ±3% (full 100 °C range) |
| Power Supply | 100–230 VAC, 50/60 Hz, ≤400 W |
| Dimensions | 43 × 43 × 43 cm (17 × 17 × 17 in) |
| Weight | 9 kg (20 lb) |
| Software | WinCTE v1.x (Windows 7–11, 32/64-bit) |
| Brand | AYAO Instruments |
|---|---|
| Origin | Hubei, China |
| Model | OPA |
| Type | Optical Power-Based Thermal Dilatometer & Phase Transition Analyzer |
| Measurement Principle | Optical Interferometry (for thermal expansion) + Reflectance Power Monitoring (for phase transition) |
| Sample Form | Free-standing films, substrate-supported thin films, bulk materials |
| Minimum Film Thickness | 1 nm |
| Non-Destructive Testing | Yes |
| Dual-Parameter Output | Coefficient of Thermal Expansion (CTE) and Phase Transition Temperature (e.g., crystallization, melting, glass transition) |
| Compliance Context | Designed for R&D environments requiring traceable, repeatable thermal property data in accordance with ISO 11359 (thermomechanical analysis), ASTM E831 (linear thermal expansion), and GLP-aligned data integrity practices |
| Brand | CRYOALL |
|---|---|
| Origin | Beijing, China |
| Model | C15V-Pro |
| Temperature Range | −263 °C to RT (10 K to ~25 °C) |
| Heating Rate | 0–50 K/min |
| Temperature Accuracy | ±0.1 K |
| Sample Length | ≤50 mm |
| Measurement Range | 0–5000 µm |
| Resolution | 0.125 nm |
| Atmosphere Options | Vacuum (1×10⁻⁵ mbar), O₂, N₂, Ar, He, H₂, forming gas |
| Contact Force | 0.01–2.5 N (motorized, programmable) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Classic |
| Temperature Range | RT to 1600 °C |
| Heating Rate | 0–50 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±5000 µm |
| Resolution | 2 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Select |
| Temperature Range | −180 °C to 2000 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±10,000 µm / ±25,000 µm |
| Resolution | 1 nm / 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme HT |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum (down to 10⁻⁵ mbar) |
| Furnace Types | Graphite, Alumina, Fused Silica |
| Optional Features | c-DTA® (calibrated Differential Thermal Analysis), Identify™ Spectral Matching, Rate-Controlled Sintering (RCS) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DIL 402 Expedis Supreme |
| Temperature Range | −180 to 2800 °C |
| Heating Rate | 0–50 K/min (up to 100 K/min with specific furnace options) |
| Temperature Accuracy | ±1 °C |
| Sample Length | 0–52 mm |
| Measurement Range | ±25,000 µm |
| Resolution | 0.1 nm |
| Atmosphere Options | Oxidizing, Reducing, Inert, Vacuum |
| Force Control | Adjustable from 10 mN to 3 N (optional) |
| Sample Types | Solid, Powder, Liquid |
| Furnace Configurations | Single or dual interchangeable furnaces |
| Patented Technologies | NanoEye displacement sensor, MultiTouch sample positioning, c-DTA® (optional), Identify spectral library (optional), Rate-Controlled Sintering (RCS, optional) |
| Brand | Orton |
|---|---|
| Origin | USA |
| Model | DIL2010C |
| Temperature Range | –170 °C to 500 °C (or RT to 1000 °C with standard configuration) |
| Max Sample Size | 50 mm length × 10 mm diameter |
| Furnace Type | Split-tube (clamshell) quartz tube furnace |
| Sample Holder & Pushrod | Fused silica |
| Thermocouple | Type N (sample & control) |
| Heating Rate | 1–30 °C/min |
| LVDT Linear Range | ±2.54 mm |
| LVDT Resolution | 0.02 µm |
| Contact Force | Adjustable |
| Cryogenic Assembly | Stainless-steel cold stage with vertical transfer tube, Dewar reservoir mounted above furnace |
| Ambient Protection | Acrylic enclosure with dry inert gas purge |
| Compliance | ASTM E228, ISO 11359-1/-2, USP <631>, GLP-ready data logging |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer | QKTester |
| Model | XRPZ-02 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 10 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Length | 150–200 mm |
| Displacement Range | 0–5 mm (±2.5 mm) |
| Resolution | 0.0001 mm |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 3 kW |
| Dimensions | 800 × 690 × 1700 mm |
| Weight | 29 kg |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKDZY-I |
| Temperature Range | 200 °C |
| Heating Rate | 80 °C/min |
| Temperature Accuracy | ±1 °C |
| Stroke/Displacement Range | 1 mm |
| Measurement Resolution | 0.01 mm |
| Atmosphere Control | 12 configurable gas channels |
| Rated Power | 1 kW |
| Rated Voltage | 220 V / 50 Hz |
| Drum Internal Diameter | Φ68 mm |
| Drum Internal Height | 120 mm |
| Steel Ball Diameter | 6 mm |
| Tumbling Speed | 90 rpm |
| Programmable Tumbling Duration | Yes |
| Overall Dimensions (L×W×H) | 700 × 640 × 690 mm |
| Net Weight | 50 kg |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Model | ZKTKK-700c |
| Temperature Range | 200 °C (max. 700 °C) |
| Max. Heating Rate | 80 °C/min |
| Temperature Accuracy | ±1 °C |
| Sample Dimensions | Ø50 mm ±1 mm × 60 mm ±1 mm |
| Measurement Range | 1 mm |
| Resolution | 0.01 mm |
| Atmosphere Control | Air (filtered, pressure-regulated, flow-controlled) |
| Flow Sensor Range | 250 L/h, ±4% FS |
| Pressure Sensor Range | 0–1 MPa, Class ≥1.5 |
| Vibration Frequency | 1 rpm |
| Rated Power | 1.5 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Device Dimensions | 750 × 700 × 1600 mm |
| Weight | 150 kg |