Thermal Shock Test Chamber
Filter
Showing 181–210 of 319 results
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -70°C to +180°C |
| Shock Transition Time | ≤5 min (typical, 150°C ↔ -70°C) |
| Internal Volume | Standard 100 L / 200 L / 400 L options |
| Control System | TEMI880 Color Touchscreen Programmable Controller (English/Chinese UI) or TEMI300 Keypad-Based Controller (English-only) |
| Compliance | IEC 60068-2-14, MIL-STD-810H Method 503.5, GB/T 2423.22 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 12,500 (FOB) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Switching Mechanism | Pneumatic damper–actuated air door, static test specimen |
| Preheating Time (RT→150 °C) | ~30 min |
| Precooling Time (RT→−70 °C) | ~85 min |
| Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Refrigeration System | Dual-stage cascade refrigeration with semi-hermetic compressors (Germany-sourced), R404A/R23 refrigerants |
| Inner Chamber Material | SUS#304 mirror-finish stainless steel |
| Outer Chamber Material | SUS#304 stainless steel or powder-coated steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m cable |
| Accessories | One Φ50 mm cable port |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -40°C to +150°C (empty load) |
| Humidity Range | 20–98% RH |
| Temperature Stability | ±0.3°C |
| Humidity Accuracy | +2 / -3% RH |
| Temperature Uniformity | ±2.0°C |
| Heating Rate | ~10 min (20°C → 150°C) |
| Cooling Rate | ~30 min (20°C → -20°C) |
| Internal Dimensions | 1000 × 1000 × 1000 mm (L×W×H) |
| External Dimensions | 1700 × 1450 × 1850 mm (L×W×H) |
| Inner Liner | Mirror-finish SUS#304 stainless steel |
| Outer Casing | Brushed-finish SUS#304 stainless steel |
| Insulation | High-density rigid PU foam + 24K glass wool |
| Refrigeration System | Hermetically sealed French Tecumseh compressor |
| Refrigerant | Eco-friendly R-404A or equivalent |
| Control System | Touchscreen HMI with bilingual (EN/CN) interface, 120 programs × 1200 segments, PID + BTHC (Balance Thermal & Humidity Control) algorithm |
| Sensor | Dual PT-100 platinum resistance thermometers |
| Resolution | 0.1°C / 0.1% RH |
| Data Logging | Built-in runtime counter, fault diagnostics, and event-triggered alarm history |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±1.5°C |
| Temp. Stability | ±0.5°C |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2% RH |
| Heating Rate | ~3°C/min (avg.) |
| Cooling Rate | ~1°C/min (avg.) |
| Internal Dimensions | 50 × 60 × 50 cm (W×H×D) |
| External Dimensions | 102 × 147 × 108 cm (W×H×D) |
| Construction | SUS304 Stainless Steel Interior |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration System | Dual-Stage Cascade (R404A/R23) |
| Control System | TEMI Programmable PID+SSR Microprocessor Controller |
| Compressor Type | Hermetic or Semi-Hermetic (Imported OEM Units) |
| Critical Components | Sporlan Expansion Valves & Filters, Castel Solenoid Valves, Alco Oil Separators, Ranco Pressure Controls |
| Cooling Method | Air-Cooled or Water-Cooled (Optional for High-Capacity Units) |
| Defrost Mode | Automatic & Manual Cycles |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Standards Compliance | IEC 60068-2-14, MIL-STD-810G Method 503.5, ASTM D6987, GB/T 2423.22–2022, GJB 150.5A–2009, QC/T 17–1992, EIA-364-32 |
| Cooling System | Dual-Stage Cascade Refrigeration (Water-Cooled) |
| Temperature Range | –65 °C to +180 °C |
| Transition Time (Typ.) | ≤30 s (–65 °C ↔ +180 °C) |
| Internal Volume Options | 150 L, 300 L, 500 L, 800 L |
| Control Accuracy | ±0.5 °C (Steady State), ±2.0 °C (Transition) |
| Humidity Control | Not Applicable (Dry Thermal Shock Only) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Dual-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Temperature Range | −65°C to +200°C |
| Transition Time (Typical) | ≤15 s between Chambers |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | −65 °C to +180 °C |
| Transition Time (Typical) | ≤15 s between chambers |
| Shock Cycle Count | 1–9999 programmable |
| Dwell Time per Zone | 0.1–999.9 h |
| Data Logging Interval | 3 s to 1 h |
| Storage Capacity | 120 days @ 60 s sampling |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Twin-Stage Cascade Refrigeration with German Semi-Hermetic Compressors |
| Cooling Water Requirement | 10 m³/h External Cooling Tower |
| Compliance | GB/T 2423.1/2/22, GJB 150.3–150.5, IEC 60068-2-14, US MIL-STD-810G Method 503.5, ASTM D648, ISO 11359-2 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | –70°C to +180°C |
| Shock Transition Time (5%–95%) | ≤15 s (between zones) |
| Cycle Count Range | 1–9999 cycles |
| Dwell Time per Zone | 0.1–999.9 h |
| Control System | PID-based LED Touch HMI with Real-Time Curve Display |
| Compliance | ASTM D573, ISO 16750-4, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Cooling System | Twin-stage cascade refrigeration (R404A/R23), equipped with French Tecumseh compressors |
| Defrost Mode | Automatic or Manual, programmable frequency |
| Structural Design | Explosion-proof ergonomic handles, insulated stainless-steel chamber walls, dual- or tri-zone configuration (selectable) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Compliance | GB/T 2423.1–2008 (Test A), GB/T 2423.2–2008 (Test B), GB/T 10592–2008, GJB 150.3–1986, GJB 360A–1996 Method 107 |
| Cooling Medium | Eco-Friendly R404A/R23 Cascade Refrigerant |
| Control Interface | LCD Touchscreen with Dialog-Based UI |
| Construction | Stainless Steel + Pre-Painted Galvanized Steel Panels |
| Air Circulation | Horizontal Centrifugal Forced-Air System with Vertical Heat Exchange |
| Safety Features | Over-Temperature/Over-Current Protection, Power-Fail Memory, Real-Time Fault Logging & Diagnostic Guidance |
| Refrigeration Architecture | Dual-Stage Cascade Cryogenic System with Zone-Specific Compressor Optimization |
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Cooling System | Two-Stage Cascade Refrigeration with Imported Semi-Hermetic Compressor (Germany) |
| External Cooling Requirement | 10 m³/h Recirculating Cooling Tower (User-Supplied) |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810G Method 503.5, GJB 150.5A-2009, GB/T 2423.22-2012, QC/T 17-1992, EIA-364-32 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Compliance | GB/T 2423.22-2002, IEC 60068-2-14, GJB 150.5-2009, MIL-STD-810H Method 503.5, QC/T 17-1992, EIA-364-32 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Cooling System | Twin-Stage Cascade Refrigeration (German Semi-Hermetic Compressors) |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.3–150.5, GJB 360.7, GJB 367.2, IEC 60068-2-14, SJ/T 10186–10187, QC/T 17, EIA-364-32 |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Temperature Range | −65 °C to +150 °C |
| Transition Time (−65 °C ↔ +150 °C) | ≤15 min (typical, per chamber-to-chamber transfer) |
| Key | Temperature Range: -40 °C to +100 °C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±5% RH |
| Ramp Rate (Heating) | ~4.0 °C/min |
| Ramp Rate (Cooling) | ~1.0 °C/min |
| Construction | Interior & Exterior – SUS304 Stainless Steel, Matte Finish |
| Insulation | High-Density Polyisocyanurate Foam (HFO-blown, Low-GWP) |
| Cooling System | Air-Cooled, Single-Stage Compressor (for -20 °C), Dual-Stage Compressor (for -40 °C to -70 °C) |
| Door Configuration | Dual-Facing Front & Rear Access Doors |
| Sample Mounting | LCD-Adjustable Tilt Fixture |
| Sensor Placement | Directly in Test Zone (Not in Air Duct) |
| Compliance Support | JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, AEC-Q200, IPC-9701, IPC-J-STD-020 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control Interface | 7-inch LCD with Bilingual (English/Chinese) UI |
| Program Storage | 120 user-defined profiles |
| Max Cycles | 9,999 |
| Max Segment Duration | 999 hrs 59 min |
| Communication | RS-232 with PC software for remote programming, data logging, and real-time monitoring |
| Temperature Transition Mode | Dual-chamber (hot/cold) or single-chamber with air flap switching |
| Recovery Time | ≤5 min (from −40 °C to +150 °C or vice versa) |
| Airflow Actuation | ≤10 s |
| Analog Output | 4–20 mA or 0–10 V DC for external recorder integration |
| Refrigeration | Twin-circuit cascade system with HFC-404A/HFC-134a eco-friendly refrigerant |
| Compressor | Imported semi-hermetic units (Europe/USA) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.3–150.5, GJB 360.7, GJB 367.2, SJ/T 10186–10187, IEC 60068-2-14 (Test N) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Method | Water-Cooled Dual-Stage Refrigeration |
| Max Cycle Count | 9999 |
| Max Dwell Time per Zone | 999 h |
| Control Interface | Touchscreen HMI |
| Thermal Transition Mode | Basket-Transfer (Dynamic Specimen Movement) |
| Operating Temperature Range | –70°C to +180°C |
| Compliance | ASTM D648, ISO 22088-3, IEC 60068-2-14, MIL-STD-810H Method 503.6 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 14,500 (FOB) |
| Chamber Configuration | Two-Zone (Hot/Cold) |
| Temperature Range | −70 °C to +180 °C |
| Transition Time (50 °C to −50 °C or vice versa) | ≤15 s (typical, 10 L load) |
| Internal Volume | 150 L standard |
| Control System | 7″ TFT Color Touchscreen PID Controller with Data Logging |
| Compliance | ASTM D5229/D5229M, ISO 16750-4, MIL-STD-810H Method 503.5, IEC 60068-2-14 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | -65°C to +180°C |
| Transfer Time (Basket) | ≤10 s |
| Dwell Time per Zone | 1–999 h |
| Cycle Count | Up to 9,999 cycles |
| Cooling Method | Water-Cooled Dual-Stage Refrigeration |
| Refrigerant | R502 |
| Controller | TEMI300 PID-based Touchscreen Interface (English UI) |
| Compliance | GB/T 10586, GB/T 10592, GB/T 2423.1/2/3/4, GB/T 5170.2/5 |
| Brand | OEM |
|---|---|
| Chamber Dimensions (W×D×H) | 460×460×460 mm / 560×660×560 mm / 680×680×650 mm / 800×800×760 mm |
| Specimen Tray Size | 360×360 mm / 460×560 mm / 600×600 mm / 700×700 mm |
| Temperature Range | High-Temp Zone: Ambient to +150 °C |
| Low-Temp Zone | Ambient to −65 °C |
| Average Ramp Rate | 1.5 °C/min |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ±2 °C |
| Transfer Time | <15 s (optional <10 s) |
| Temperature Recovery Time | <5 min |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.5, GJB 360.7, GJB 367.2, SJ/T 10186, SJ/T 10187 |
| Key Specifications | Temperature Range: -65°C to +180°C (typical) |
|---|---|
| Transfer Time | ≤15 s (dual-compartment), ≤30 s (three-zone) |
| Recovery Time | ≤5 min (standard load) |
| Internal Volume | 100–1000 L (configurable) |
| Cooling Method | Dual-stage cascade refrigeration with water-cooled condensers |
| Compliance | GB/T 2423.1–2, GB/T 2423.22, GJB 150.5, IEC 60068-2-14, MIL-STD-810H Method 503.5, ASTM D648, ISO 11359-2 |
| Power Supply | 380 VAC ±10%, 3-phase, 50/60 Hz |
| Water Cooling Requirement | External cooling tower (10 m³/h flow rate, 32°C max inlet temperature) |
| Control System | PID-based programmable controller with Ethernet interface |
| Data Logging | Built-in memory + optional USB/RS485 export |
| Safety Features | Over-temperature, over-pressure, compressor high/low pressure, phase failure, door interlock |
| Key | Temperature Range: -40 to 100°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1°C |
| Humidity Uniformity | ±5% RH |
| Door Configuration | Dual-front & rear access doors |
| Heating Load Capacity | Customizable per user specification |
| Cooling System | Air-cooled, single-stage compressor (for -20°C base) / dual-stage compressor (for -40°C to -70°C operation) |
| Ramp Rates | ~4.0°C/min (heating), ~1.0°C/min (cooling) |
| Construction | Interior and exterior walls in brushed SUS304 stainless steel |
| Viewing Window | Low-condensation coated electrothermal glass |
| Control System | PLC-based programmable controller with color touchscreen HMI |
| Compliance | Designed to support IEC 60068-2-14, MIL-STD-810H Method 503.5, JESD22-A104, and JEDEC J-STD-020 for lead-free solder process validation |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Controller Options | TEMI880 Color Touchscreen (EN/CN Switchable) or TEMI300 Membrane Keypad (English Only) |
| Temperature Range | −70 °C to +180 °C (Dual-Zone Independent Control) |
| Humidity Range | 20–98% RH (Optional Humidification) |
| Cooling System | Twin-Stage Cascade Refrigeration with Original Tecumseh (France) Hermetic Compressor |
| Insulation | Polyurethane Rigid Foam (150 mm) + Ultra-Fine Glass Fiber Blanket |
| Interior Material | SUS304 Stainless Steel |
| Exterior Finish | Electrostatic Powder-Coated Cold-Rolled Steel or Optional Brushed SUS304 |
| Airflow | Wide-Band Forced Convection via Centrifugal Blower (Top-Out / Bottom-In) |
| Compliance | Meets ASTM D5229, IEC 60068-2-14, MIL-STD-810H Method 503.7 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |